Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Experimental set-up

Physics and chemistry are carried out in laboratory frames using coordinate systems to set up experimental devices. Before discussing quantum mechanical processes let us recall the form of the total Hamiltonian for a set of particles having charges qa and masses ma interacting with an electromagnetic field A. This Hamiltonian is given by ... [Pg.313]

It was also possible to set up experimental conditions in which either dp /dx or ZjFdty/dx could be reduced to zero. For example, by switching off the externally applied field, d<)>/dx inside the electrolyte could be reduced to zero. Similarly, by avoiding a concentration gradient inside the electrolyte, dp /dx can be directed to zero. Thus, the gradients of the chemical potential and the electric potential, i.c., the chemical and electrical driving forces, could be determined separately. [Pg.115]

The variation of potential with distance is shown in Fig. 3C for the three configurations just discussed. It should be clear that the spherical configuration is the best in reducing the error that results from a residual iR potential drop, and the planar is the worst. In spite of this, the cylindrical configuration is often used in research, because it is only a little worse than the spherical but much better than the planar configuration, and is easier to set up experimentally than the spherical configuration. [Pg.32]

Set up experimental program with appropriate parameters, including impeller type, speed, seed amount, seed size, rate of cooling or addition, point of addition. [Pg.273]

The second section examines setting up experimental and processing parameters both manually and using the automatic NMR Wizard. The concept of configuration and job files is introduced and examples used to show how using this approach simulation experiments may be quickly set up and modified. Finally the use of NMR-SIM to optimize experimental parameters is discussed and different ways of displaying the results examined. [Pg.112]

A space in the Reactor Building shall be made accessible for setting up experimental equipment. This is desirable because the external equipment needed for the testing of the reactor fuel elements is quite extensive, snd in some cases may have to be heavily shielded. [Pg.113]

In this section we have described the experimental set up, experimental procedure, proposed method and results. [Pg.199]

Although this condition can be troublesome to set up experimentally, it does have the advantage that all of the signal can be easily collected. But for gas-phase studies where the refractive index dispersion is small, collinear beams can usually be used. [Pg.246]

In spite of all these issues, it should still be useful to set up experimentally an (expectedly linear) equation relating to the value of w and the size of the water pool for a particular system for tailoring the aqueous nanoreactor and the particle size. As is shown above, such equations should be valid for specific systems and specific ranges of w. [Pg.66]

This chapter is organized as follows. We start with a representation of the transmission line as two conductors in section 2. We describe the set up experimental in section 3. The next section deals with experimental determination of channel impedance and propagation constant. In section 5, the power channel model is established. In section 6 the proposed deterministic method is generalized to network with N nodes and M branches. Section 7... [Pg.1]

Equation 3 could be used to measure the diffusion coefficient of the species because x could be set up experimentally. Equation 2 can be used to simulate the PBD signal of a continuous electrochemical reaction. That is, when the redox species are transformed during the whole time span of the measurement. This is the case of redox reactions in solutions (e.g., Fe" electro-chemically oxidized to Fe" ), but in such cases, several concentration gradients have to be considered and interpretation is difficult. A simpler system involves metal deposition by reduction of a metal ion (e.g., Ag" ) to metal (Ag°), where only one concentration gradient have to be considered. [Pg.1741]

If Pf x, y ) is constant, or zero, over the soap film surface it is a simple procedure to set up experimentally the pressure difference using gas, or air, on one side of the film that is at a different pressure than that on the other side. However, if a pressure distribution is required it will be necessary to produce a pressure variation over the surface by means of pressure jets which can be altered to give the required pressure distribution. This is more difficult to set up experimentally. [Pg.183]

Another example of a microscale operation is the RADMASTE kit, distributed from South Africa and used in a number of countries. This kit is available in different versions, ranging from primary science, chemistry and biology and offers the potential for setting up experimental situations that would be difficult under normal circumstances. An illustration of a water kit is given in Figure 3 plus a picture of a collection of publications on experimental ideas taken from the ICASE website (Figure 4). [Pg.322]

Figure 3 Experimental set-up for bond inspeelion (a) and probe for the Fokker Bond Tester (b). Figure 3 Experimental set-up for bond inspeelion (a) and probe for the Fokker Bond Tester (b).
The new design of photothermal eamera has been thoroughly evaluated on different kinds of cracked metallic (mainly steel) parts in order to compare its sensitivity to the one of penetrants. For that purpose, an experimental set-up has been built. [Pg.395]

The SPATE technique is often used to perfonn an experimental validation of the physical behaviour of stressed structures or components. This is the reason why the design activity is usually combined with the SPATE technique used on prototypes in order to provide a good set up of mechanically stressed elements. [Pg.408]

Some preliminary tests were performed to set up the experimental apparatus, to check the sensors (pressure and strain gauges) and the SPATE system operation. [Pg.410]

This paper deals with the control of weld depth penetration for cylinders in gold-nickel alloy and tantalum. After introducing the experimental set-up and the samples description, the study and the optimization of the testing are presented for single-sided measurements either in a pulse-echo configuration or when the pump and the probe laser beams are shifted (influence of a thermal phenomenon), and for different kind of laser impact (a line or a circular spot). First, the ultrasonic system is used to detect and to size a flat bottom hole in an aluminium plate. Indeed, when the width of the hole is reduced, its shape is nearly similar to the one of a slot. Then, the optimization is accomplished for... [Pg.693]

Figure 1 shows the schematic of the experimental set up used for the time-of-flight diffraction... [Pg.722]

State I ) m the electronic ground state. In principle, other possibilities may also be conceived for the preparation step, as discussed in section A3.13.1, section A3.13.2 and section A3.13.3. In order to detemiine superposition coefficients within a realistic experimental set-up using irradiation, the following questions need to be answered (1) Wliat are the eigenstates (2) What are the electric dipole transition matrix elements (3) What is the orientation of the molecule with respect to the laboratory fixed (Imearly or circularly) polarized electric field vector of the radiation The first question requires knowledge of the potential energy surface, or... [Pg.1059]

Figure Bl.4.6. Left an experimental optieal THz pump-probe set-up using sub-pieoseeond THz pulse generation and deteetion by the eleetro-optie effeet. Right the applieation of sueh pulses to the relaxation of optieally exeited TBNC in toluene. The THz eleetrie field used for these experiments is shown in the upper-right inset. Tluee exponential deeay tenns, of order 2, 50 and 700 ps, are required to fit the observed temporal relaxation of the solvent [51]. Figure Bl.4.6. Left an experimental optieal THz pump-probe set-up using sub-pieoseeond THz pulse generation and deteetion by the eleetro-optie effeet. Right the applieation of sueh pulses to the relaxation of optieally exeited TBNC in toluene. The THz eleetrie field used for these experiments is shown in the upper-right inset. Tluee exponential deeay tenns, of order 2, 50 and 700 ps, are required to fit the observed temporal relaxation of the solvent [51].
There have been a few other experimental set-ups developed for the IR characterization of surfaces. Photoacoustic (PAS), or, more generally, photothemial IR spectroscopy relies on temperature fluctuations caused by irradiating the sample with a modulated monocliromatic beam the acoustic pressure wave created in the gas layer adjacent to the solid by the adsorption of light is measured as a fiinction of photon wavelength... [Pg.1785]

Figure C 1.5.13. Schematic diagram of an experimental set-up for imaging 3D single-molecule orientations. The excitation laser with either s- or p-polarization is reflected from the polymer/water boundary. Molecular fluorescence is imaged through an aberrating thin water layer, collected with an inverted microscope and imaged onto a CCD array. Aberrated and unaberrated emission patterns are observed for z- and xr-orientated molecules, respectively. Reprinted with pennission from Bartko and Dickson [148]. Copyright 1999 American Chemical Society. Figure C 1.5.13. Schematic diagram of an experimental set-up for imaging 3D single-molecule orientations. The excitation laser with either s- or p-polarization is reflected from the polymer/water boundary. Molecular fluorescence is imaged through an aberrating thin water layer, collected with an inverted microscope and imaged onto a CCD array. Aberrated and unaberrated emission patterns are observed for z- and xr-orientated molecules, respectively. Reprinted with pennission from Bartko and Dickson [148]. Copyright 1999 American Chemical Society.

See other pages where Experimental set-up is mentioned: [Pg.82]    [Pg.11]    [Pg.25]    [Pg.13]    [Pg.222]    [Pg.25]    [Pg.82]    [Pg.11]    [Pg.25]    [Pg.13]    [Pg.222]    [Pg.25]    [Pg.38]    [Pg.52]    [Pg.694]    [Pg.694]    [Pg.723]    [Pg.822]    [Pg.655]    [Pg.1168]    [Pg.1174]    [Pg.1689]    [Pg.1716]    [Pg.1731]    [Pg.1736]    [Pg.1781]    [Pg.1791]    [Pg.1847]    [Pg.1976]    [Pg.2123]    [Pg.2126]    [Pg.3027]   
See also in sourсe #XX -- [ Pg.13 ]




SEARCH



Experimental Demonstration of the Novel Process Concept in a Pilot-Scale Set-Up

Experimental Set-ups

Experimental set-up for spin-dependent measurements

Experimental set-ups and methodologies

Experimental spectroscopy measured quantities and set-ups

Fundamentals of PM IRRAS and Experimental Set-up

Modeling and Experimental Set-up

The CRMC2-Marseille experimental set-up

The Fritz Haber Institut experimental set-up

Theory and Experimental Set-Up of a Scanning Kelvin Probe

© 2024 chempedia.info