Sample plate

Compounds Sample Plate Eluent Alkaloids Detection Remarks Reference... [Pg.260]

The sample plate is prepared as in the preceding method. But before the spectra are taken, a volume Y of a water-miscible cosolvent is added to a volume Z of sample... [Pg.108]

The reference plate is prepared differently. A known quantity of sample is added to a known volume of system solution of known pH with the amount of sample comparable to that found in the sample plate, and no effort is made in this step to suppress precipitation in the formed solution. A volume Y of the cosolvent is immediately added to a volume Z of reference solution to produce a new solution, in which the compound is now diluted by Z/(Y + Z). The spectrum of the solution is then immediately taken by the UV spectrophotometer. Mathematical treatment of the spectral data yields the area under the curve of the cosolvent reference solution, AUC 0S. Define Rcos = AUC 0S /AUC(v os. The solubility of the sample compound then is... [Pg.109]

Although detector balancing takes only a few seconds on typical instruments, the need to do so should be assessed. The time and numbers of samples lost over time to balance a detector may be considerable. Perhaps only a detector balance between sample plates will do. This can be accomplished by so-called pre-run macros or scripts that can be executed between individual sample lists by many acquisition software packages. [Pg.109]

Also for MALDI, there is a special case worth mentioning. Surface-enhanced laser desorption/ionization (SELDI) is a technique that utilizes special sample plates [196, 197]. These have different modified surfaces, for example, hydrophobic, anionic, or antibody treated. Which type of surface to select depends on the application. After application of analyte the surface is washed according to a protocol leaving only the desired components on the target. Finally, a MALDI matrix is applied before analysis in the spectrometer. See Chapter 12 for an application example of SELDI. [Pg.37]

TLC analysis of samples was conducted on silica-gel plates carefully spotted with 10-20 pg of standard compounds, and 30 pL of bioconversion reaction samples. Plates developed with 75 25 1 (v/v/v) CH2CI2/CH3CN/HCOOH solvent may be visualized with a 254 nm UV lamp and/or by spraying with a 30 % w/v phosphomolybdic acid/ 95% ethanol spray reagent followed by gentle heating. Rf values of standards are vanillyl alcohol, 0.8 vanillic acid, 0.5 and vanillin 0.4. [Pg.297]

One typical example of carbon/carbon composite plates is that made by Oak Ridge National Laboratory (ORNL) in the United States [12]. The composite preform was fabricafed by a slurry-molding process from fhe mixed slurry befween short carbon fibers (graphite fibers were also added in some sample plates) and fhe phenolic resin. The mass rafio between fiber reinforcement and phenolic matrix is 4 3. The phenolic matrix improves the mechanical properties and dimensional stability of the plate. A subsequent vacuum molding process was utilized to fabricate composite plates and fluid fields with relatively high resolution (Figure 5.3, [11]). [Pg.317]

Matrix assisted laser desorption ionization time-of-flight (MALDI-TOE) mass spectrometry was carried out with a PerSeptive Biosystems Voyager-DE-RP MALDl-TOF mass spectrometer. A 337-nm UV nitrogen laser producing 3-ns pulses was used in the reflectron mode. The samples were prepared by mixing 10 pi of a 0.1 M HAc solution of the sample with 20 pi of a solution of 3 mg/1 a-cyano-4-hydroxy cinnamic acid in wafer. One pi of that solution was loaded on the gold-sample plate. [Pg.78]

Pipet 0.5 pL of sample to the sample plate. Preferable concentration lpmol -pL Mix the sample and matrix2 by drawing in and out of the pipette. Allow to air dry and acquire spectra. aFor peptides, small proteins, and most other compounds a sat. soln of 2-cyano-3-(4-hydro-xyphenyl)acrylic acid in 0.1% TFA in H20/MeCN (1 1) is used. This matrix requires about half the laser energy of other matrices. [Pg.689]

Invert all plates. Incubate two of the test sample plates and one negative control plate at 30 to 35°C for no less than 72 hours. Incubate the remaining two plates and the remaining negative control plate anaerobically in anaerobic jar. Incubate at 30 to 35°C for no less than 72 hours. [Pg.947]

Thermal Neutron Activation Analysis (NAA). The amount of sample adhering to the quartz sampling plate is variable. It is normally considered to be of the order of 100-200 /xg. Because of the size of the metallurgical samples available for this study, the average mass sampled was estimated to be in the range 1-5 /xg. [Pg.23]

Fixed volumes of original solution and of collapsed foams were taken with a micro (overflow type) pipet and transferred to respective sample plates which were coated partly with silicone oil to prevent wetting. The solution was dried gradually with infrared ray lamp and then radioactive counts were determined. On the other hand, the concentration of the solution of collapsed bubbles was determined by weighing. The accuracy of this method was confirmed by drying the solution of known concentration at respective experiments. The loss of acetic acid... [Pg.207]

There are several direct ways to transfer tissue slices to the sample plate. First, the frozen tissue slice is gently positioned on the cold target plate (—15°C) using an artist s bmsh and thawmounted onto the plate by quickly moving it out of the cryostat chamber the frozen section then adheres to the MALDI plate when held at room temperature. As an alternative procedure, one can attach the section to a doublesided transparent tape, which is then glued on the sample plate (Schwartz et al., 2003). [Pg.364]

Once the tissue slice is mounted on the sample plate, the sample preparation becomes the critical step in the process. In general, two strategies are employed to apply matrix... [Pg.364]

More recently, significant effort has been put into using direct-flow NMR probes such as HPLC-NMR probes for analysing the components of combinatorial chemistry libraries but without the need for an HPLC separation first [26], In this case, 88 samples from a combinatorial chemistry synthesis were placed in a 96-well plate and after the NMR spectra were measured the samples could be returned to the sample plate for further analysis or... [Pg.55]

Fig. l.A sample plate from a screen to identify small molecules that upregulate the expression of a cyclin-luciferase reporter protein. HeLa cells were infected with an adenovirus expressing cyclin-luciferase, as described in the methods section. The graph shows the activity of all wells from a single 384-well plate. Several compounds that upregulate cyclin-luciferase expression were identified. [Pg.192]

One example of a miniaturized LC/MS strategy is the use of 96-well sample plates (Kaye et al., 1996) for extraction. This sample extraction procedure combines batch sample processing within a miniaturized format. Increased sensitivity and decreased volume advances have fostered a new wave of scale-down models. Experiments that were formerly performed at the bench are, instead, performed at the microliter scale in the batch mode. For example, synthetic process research was traditionally performed manually with apparatus at the milliliter level. This approach involves the testing of a range of synthetic conditions for optimum yield and minimum impurity production. Now, process research conditions are tested in microliter levels to produce information on purity and structure (Rourick et al., 1996). This strategy requires fewer reagents and accelerates the evaluation of a wider range of conditions in a shorter time. Another example includes the direct analysis of samples from cell culture experiments (Kerns et al., 1997). [Pg.55]

Sampling Unit (Fig. 16). The current sample plate contains forty... [Pg.338]

The samples must be kept under oil to prevent losses of C02 from occurring during the time the specimens are on the sample plate. This appears to offer no major problem in the conduct of the analysis. [Pg.353]

Should one attempt to adapt a test to the Autoanalyzer, certain characteristics of the instrument become apparent. Each one of the individual units—sample plate, pump and tubing, dialyzer, heating bath, and recording colorimeter—has certain aspects of optimal performance and others of minimal or restrictive performance. The relationships of these units to a flowing stream must be considered along with contamination effects. [Pg.354]


See other pages where Sample plate is mentioned: [Pg.1046]    [Pg.462]    [Pg.201]    [Pg.40]    [Pg.43]    [Pg.359]    [Pg.155]    [Pg.292]    [Pg.430]    [Pg.255]    [Pg.290]    [Pg.163]    [Pg.24]    [Pg.192]    [Pg.51]    [Pg.57]    [Pg.365]    [Pg.370]    [Pg.377]    [Pg.390]    [Pg.93]    [Pg.228]    [Pg.229]    [Pg.104]    [Pg.105]    [Pg.339]   


SEARCH



96-well sample plates

Anchor sample plates

Liquid parallel-plate sample cells

Metal sample plate

Parallel-plate separators isokinetic sample

Parallel-plate separators sample train

Sample Plates for Low-Volume High-Throughput Screening

Sampling glass plate