Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Capillary electrophoresis sample

In capillary electrophoresis the conducting buffer is retained within a capillary tube whose inner diameter is typically 25-75 pm. Samples are injected into one end of the capillary tube. As the sample migrates through the capillary, its components separate and elute from the column at different times. The resulting electrophero-gram looks similar to the chromatograms obtained in GG or HPLG and provides... [Pg.597]

The basic instrumentation for capillary electrophoresis is shown in Figure 12.41 and includes a power supply for applying the electric field, anode and cathode compartments containing reservoirs of the buffer solution, a sample vial containing the sample, the capillary tube, and a detector. Each part of the instrument receives further consideration in this section. [Pg.601]

Schematic diagram for capillary electrophoresis. The sample and source reservoir are switched when making injections. Schematic diagram for capillary electrophoresis. The sample and source reservoir are switched when making injections.
An injection technique in capillary electrophoresis in which pressure is used to inject sample into the capillary column. [Pg.602]

Injecting the Sample The mechanism by which samples are introduced in capillary electrophoresis is quite different from that used in GC or HPLC. Two types of injection are commonly used hydrodynamic injection and electrokinetic injection. In both cases the capillary tube is filled with buffer solution. One end of the capillary tube is placed in the destination reservoir, and the other is placed in the sample vial. [Pg.602]

Capillary Zone Electrophoresis The simplest form of capillary electrophoresis is capillary zone electrophoresis (CZE). In CZE the capillary tube is filled with a buffer solution and, after loading the sample, the ends of the capillary tube are placed in reservoirs containing additional buffer solution. Under normal conditions, the end of the capillary containing the sample is the anode, and solutes migrate toward... [Pg.604]

Source Adapted from Baker, D. R. Capillary Electrophoresis. Wiley-Interscience New York, 1995. "Concentration depends on the volume of sample injected. [Pg.605]

The last set of experiments provides examples of the application of capillary electrophoresis. These experiments encompass a variety of different types of samples and include examples of capillary zone electrophoresis and micellar electrokinetic chromatography. [Pg.614]

Capillary Electrophoresis. Capillary electrophoresis (ce) or capillary 2one electrophoresis (c2e), a relatively recent addition to the arsenal of analytical techniques (20,21), has also been demonstrated as a powerful chiral separation method. Its high resolution capabiUty and lower sample loading relative to hplc makes it ideal for the separation of minute amounts of components in complex biological mixtures (22,23). [Pg.61]

Capillary Electrophoresis. Capillary electrophoresis (ce) is an analytical technique that can achieve rapid high resolution separation of water-soluble components present in small sample volumes. The separations are generally based on the principle of electrically driven ions in solution. Selectivity can be varied by the alteration of pH, ionic strength, electrolyte composition, or by incorporation of additives. Typical examples of additives include organic solvents, surfactants (qv), and complexation agents (see Chelating agents). [Pg.246]

Capillary Electrophoresis. Capillaries were first appHed as a support medium for electrophoresis in the early 1980s (44,45). The glass capillaries used are typically 20 to 200 p.m in diameter (46), may be filled with buffer or gel, and are frequendy coated on the inside. Capillaries are used because of the high surface-to-volume ratio which allows high voltages without heating effects. The only limitations associated with capillaries are limits of detection and clearance of sample components. [Pg.183]

Identification of stmctures of toxic chemicals in environmental samples requires to use modern analytical methods, such as gas chromatography (GC) with element selective detectors (NPD, FPD, AED), capillary electrophoresis (CE) for screening purposes, gas chromatography/mass-spectrometry (GC/MS), gas chromatography / Fourier transform infra red spectrometry (GC/FTIR), nucleai magnetic resonance (NMR), etc. [Pg.416]

Electropherograms of a urine sample (8 ml) spiked with non-steroidal anti-inflammatory drugs (10 p-g/ml each) after direct CE analysis (b) and at-line SPE-CE (c). Peak identification is as follows I, ibuprofen N, naproxen K, ketoprofen P, flurbiprofen. Reprinted from Journal of Chromatography, 6 719, J. R. Veraait et al., At-line solid-phase exti action for capillary electrophoresis application to negatively charged solutes, pp. 199-208, copyright 1998, with permission from Elsevier Science. [Pg.287]

Figure 11.19 SPME-CE analysis of urine samples (a) blank urine (a) directly injected and extracted for (b) 5 (c) 10 and (d) 30 min (b) Urine spiked with barbiturates, extracted for (e) 30 and (f, g) 5 min. Peak identification is as follows 1, pentobaitibal 2, butabarbital 3, secobarbital 4, amobarbital 5, aprobarbital 6, mephobarbital 7, butalbital 8, thiopental. Concenti ations used are 0.15-1.0 ppm (e, f) and 0.05-0.3 ppm (g). Reprinted from Analytical Chemistry, 69, S. Li and S. G. Weber, Determination of barbiturates by solid-phase microexti action and capillary electrophoresis, pp. 1217-1222, copyright 1997, with permission from the American Chemical Society. Figure 11.19 SPME-CE analysis of urine samples (a) blank urine (a) directly injected and extracted for (b) 5 (c) 10 and (d) 30 min (b) Urine spiked with barbiturates, extracted for (e) 30 and (f, g) 5 min. Peak identification is as follows 1, pentobaitibal 2, butabarbital 3, secobarbital 4, amobarbital 5, aprobarbital 6, mephobarbital 7, butalbital 8, thiopental. Concenti ations used are 0.15-1.0 ppm (e, f) and 0.05-0.3 ppm (g). Reprinted from Analytical Chemistry, 69, S. Li and S. G. Weber, Determination of barbiturates by solid-phase microexti action and capillary electrophoresis, pp. 1217-1222, copyright 1997, with permission from the American Chemical Society.
Huang, H.Y. et al.. Analysis of food colorants by capillary electrophoresis with large-volume sample stacking, J. Chromatogr. A, 995, 29, 2003. [Pg.530]

Galli, V., Garcia, A., Saavedra, L., and Barbas, C. (2003). Capillary electrophoresis for short-chain organic acids and inorganic anions in different samples. Electrophoresis 24, 1951-1981. [Pg.127]

A variety of formats and options for different types of applications are possible in CE, such as micellar electrokinetic chromatography (MEKC), isotachophoresis (ITP), and capillary gel electrophoresis (CGE). The main applications for CE concern biochemical applications, but CE can also be useful in pesticide methods. The main problem with CE for residue analysis of small molecules has been the low sensitivity of detection in the narrow capillary used in the separation. With the development of extended detection pathlengths and special optics, absorbance detection can give reasonably low detection limits in clean samples. However, complex samples can be very difficult to analyze using capillary electrophoresis/ultraviolet detection (CE/UV). CE with laser-induced fluorescence detection can provide an extraordinarily low LOQ, but the analytes must be fluorescent with excitation peaks at common laser wavelengths for this approach to work. Derivatization of the analytes with appropriate fluorescent labels may be possible, as is done in biochemical applications, but pesticide analysis has not been such an important application to utilize such an approach. [Pg.781]


See other pages where Capillary electrophoresis sample is mentioned: [Pg.321]    [Pg.444]    [Pg.267]    [Pg.624]    [Pg.321]    [Pg.444]    [Pg.267]    [Pg.624]    [Pg.598]    [Pg.610]    [Pg.771]    [Pg.773]    [Pg.779]    [Pg.277]    [Pg.395]    [Pg.397]    [Pg.246]    [Pg.183]    [Pg.183]    [Pg.54]    [Pg.299]    [Pg.198]    [Pg.73]    [Pg.90]    [Pg.162]    [Pg.147]    [Pg.78]    [Pg.110]    [Pg.76]    [Pg.435]    [Pg.453]    [Pg.263]    [Pg.267]    [Pg.773]   
See also in sourсe #XX -- [ Pg.95 ]




SEARCH



Capillary electrophoresis sample injection

Capillary electrophoresis sample introduction

Capillary electrophoresis sample preparation

Capillary electrophoresis sample stacking

Capillary electrophoresis sample volume/concentration

Capillary electrophoresis, separation samples

Capillary sample

Capillary zone electrophoresis sample

Pharmaceutical samples capillary electrophoresis- mass

© 2024 chempedia.info