Sample application split

There are several types of sample introduction systems available for GC analysis. These include gas sampling valves, split and splitless injectors, on-column injection systems, programmed-temperature injectors, and concentrating devices. The sample introduction device used depends on the application. [Pg.9]

In this mode of operation, the split valve is open throughout (Figure 2.70). In classical sample application, this mode of injection is suitable for concentrated solutions, through which the column loading can be adapted to its capacity and... [Pg.119]

Digitalis glycosides Apply the sample solution as a band, then cover the layer, apart from the application zone, with a glass plate and place it in an ammonia chamber for 24 to 48 h, remove excess ammoma and chromatograph Acetyl groups are split off [37]... [Pg.63]

In a conventional Fe Mossbauer experiment with a powder sample, one would observe a so-called quadrupole doublet with two resonance lines of equal intensities. The separation of the lines, as given by (4.36), represents the quadrupole splitting The parameter Afg is of immense importance for chemical applications of the Mossbauer effect. It provides information about bond properties and local symmetry of the iron site. Since the quadrupole interaction does not alter the mean energy of the nuclear ground and excited states, the isomer shift S can also be derived from the spectrum it is given by the shift of the center of the quadrupole spectrum from zero velocity. [Pg.93]

Numerous types of GC injectors have been manufactured over the past four decades. The most commonly used injection techniques have been reviewed and described by Grob, who correctly states that analysts must fully understand the techniques before they can make the most appropriate choice for their particular application(s). For most GC capillary column applications, the split/splitless, programmed-temperature vaporization (PTV) and on-column injectors remain the most popular. However, over the last few years, technology has progressed rapidly to provide injectors that allow more of the sample extract on to the GC column without overloading it. [Pg.738]

The applicable HPLC flow rate with ESI is lower than that with thermospray or APCI, usually below the O.SmLmin range. The typical flow rate is 0.10-0.20 mL min for ESI, which means that the effluent flow introduced into the electrospray must be reduced by splitting when using a conventional HPLC column (4.6-mm i.d. x 250 mm). Currently, narrower columns (e.g., 2.1-mm i.d.) and slower flow rates are commonly used to achieve the desirable flow rates. The advantage of this approach is that improved separation efficiency and faster separations are also achieved (at the cost of sample capacity). [Pg.767]

The nuclear transitions are very sensitive to the local environment of the atom, and Mossbauer spectroscopy is a sensitive probe of the different environments an atom occupies in a solid material. By analyzing the chemical shifts and quadrupole splitting in Mossbauer spectra of samples containing Mossbauer-ac-tive nuclei, information on the state of oxidation and the local structure can be obtained. Only a few nuclei can be used for this purpose, so this method has limited but powerful applications. [Pg.60]

For capillary GC, the split/splitless inlet is by far the most common and provides an excellent injection device for most routine applications. For specialized applications, there are several additional inlets available. These include programmed temperature vaporization (PTV) cool on-column and, for packed columns, direct injection. PTV is essentially a split/splitless inlet that has low thermal mass and a heater allowing rapid heating and cooling. Cool injection, which can be performed in both split and splitless mode with the PTV inlet, reduces the possibility of sample degradation in the inlet. Capabilities of the commonly available inlets are summarized in Table 14.3. [Pg.464]

Another difficulty in the gas chromatographic separation of amino acids is the choice of detector and it may be necessary to split the gas stream and use two different detectors. The flame ionization detector, which is commonly used, is non-specific and will detect any non-amino acid components of the sample unless purification has been performed prior to derivatization. In addition the relative molar response of the flame ionization detector varies for each amino acid, necessitating the production of separate standard curves. As a consequence, although gas chromatography offers theoretical advantages, its practical application is mainly reserved for special circumstances when a nitrogen detector may be useful to increase the specificity. [Pg.372]

A bit of a chemical application arose in our attempts to find a monochromatic source or absorber. Since EuF. > has fiuorite structure, there should be no quadrupole splitting. When a spectrum was taken of a commercial sample of EUF2 it was found that the europium present was essentially completely trivalent. The experimental spectrum is shown in Figure 9. [Pg.124]

Mossbauer spectroscopy The Mossbauer effect is resonance absorption of 7 radiation of a precisely defined energy, by specific nuclei. It is the basis of a form of spectroscopy used for studying coordinated metal ions. The principal application in bioinorganic chemistry is Fe. The source for the 7 rays is Co, and the frequency is shifted by the Doppler effect, moving it at defined velocities (in mm/s) relative to the sample. The parameters derived from the Mossbauer spectrum (isomer shift, quadrupole splitting, and the hyperfine coupling) provide information about the oxidation, spin and coordination state of the iron. [Pg.252]


See other pages where Sample application split is mentioned: [Pg.127]    [Pg.229]    [Pg.154]    [Pg.229]    [Pg.359]    [Pg.360]    [Pg.4]    [Pg.1979]    [Pg.246]    [Pg.257]    [Pg.378]    [Pg.162]    [Pg.285]    [Pg.2]    [Pg.371]    [Pg.800]    [Pg.233]    [Pg.188]    [Pg.304]    [Pg.468]    [Pg.27]    [Pg.47]    [Pg.301]    [Pg.412]    [Pg.26]    [Pg.31]    [Pg.720]    [Pg.38]    [Pg.107]    [Pg.168]    [Pg.104]    [Pg.253]    [Pg.123]    [Pg.382]    [Pg.188]    [Pg.434]    [Pg.519]    [Pg.214]    [Pg.323]   