Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Reference measurement technique

The effective thermal conductivity can be determined using the methods presented in Table 4.5, which includes the relevant references. Measurement techniques for thermal conductivity can be grouped into steady-state and transient-state methods. Transient methods are more popular because they can be run for as short as 10 s, during which time the moisture migration and other property changes are kept minimal. [Pg.86]

The effective thermal conductivity can be determined using the methods presented in Table 4.5, which includes the relevant references. Measurement techniques for thermal conductivity can be grouped into... [Pg.109]

Measurement technique Value, MPa Reference Value, MPa " Reference... [Pg.318]

Quimtua Yields of Fluorescence Measurements. All of the quantum yields of fluorescence were measured by the relative fluorescence measurement technique of Parker and Rees (24). This method compares the fluorescence of the compound of interest to the fluorescence of some known compound. All of the fluorescence quantum yields were measured using I as a reference. Compound I had previously been measured by this same method using rhodamine B as a standard. [Pg.221]

As usually viewed by the reference material producers, a fundamental philosophy of certification rests on the concept of independent methodology, which is the application of theoretically and experimentally different measurement techniques and procedures to generate concordant results leading to one reliable assigned value for the property. Such assigned values are thus method-independent. Extractable concentrations are generated by specific procedures and are thus method-dependent, an idea that has to be rationalized with the fundamental method-independent concept in reference material certification work. [Pg.286]

In this chapter, a number of transport phenomena with entirely different natures are compared for liquids filling porous systems. Here transport can refer to flow, diffusion, electric current or heat transport. Corresponding NMR measuring techniques will be described. Applications to porous model objects will be juxtaposed to computational fluid dynamics simulations. [Pg.205]

Principles and Characteristics Voltammetric methods are electrochemical methods which comprise several current-measuring techniques involving reduction or oxidation at a metal-solution interface. Voltammetry consists of applying a variable potential difference between a reference electrode (e.g. Ag/AgCl) and a working electrode at which an electrochemical reaction is induced (Ox + ne ----> Red). Actually, the exper-... [Pg.669]

In the simplest case, experimental calibration can be carried out by direct reference measurements where the sensitivity factor b is given by the relation of measured value to concentration of a reference material (RM), b = yRvi/xRv,. Direct reference calibration is frequently used in NAA and X-ray analytical techniques (XRF, EPMA, TXRF). [Pg.150]

Reference Growth process Hydrogen content (at. %) Deposition temperature (°C) ED(eV) D0(cm2/sec) Measurement technique... [Pg.439]

Adiabatic calorimetry Chemical testing technique that determines the self-heating rate and pressure data of a chemical under near-adiabatic conditions. ( Adiabatic refers to any change in which there is no gain or loss of heat.) This measurement technique conservatively estimates the conditions for, and consequences of, a runaway reaction. [Pg.369]

We refer to this as a thermochemical measurement when, in fact, the necessary equilibrium measurement techniques are usually found among the arsenal of the kineticist. A minor distinction to the reader perhaps, but it appears to the authors that except for Benson and his descendants, thermochemists and kineticists generally inadequately communicate. [Pg.376]

Reference materials are homogeneous, stable substances whose properties are sufficiently established as to make them useful for calibrating analytical instruments or validating measurement techniques. High-quality reference materials not only provide essential support for large-scale research studies, but also ensure accuracy of long time-series measure-... [Pg.16]

Reported flame speed results for most fuels vary somewhat with the measurement technique used. Most results, however, are internally consistent. Plotted in Fig. 4.21 are some typical flame speed results as a function of the stoichiometric mixture ratio. Detailed data, which were given in recent combustion symposia, are available in the extensive tabulations of Refs. [24-26], The flame speeds for many fuels in air have been summarized from these references and are listed in Appendix F. Since most paraffins, except methane, have approximately the same flame temperature in air, it is not surprising that their flame speeds are about the same (—45 cm/s). Methane has a somewhat lower speed (<40 cm/s). Attempts [24] have been made to correlate flame speed with hydrocarbon fuel structure and chain length, but these correlations... [Pg.187]

Environmental control that fixes a known concentration of solvent in the membrane under test is also important. The reader is encouraged to consult the review, and references therein, of conductivity measurement techniques by Doyle and Rajendran. ... [Pg.329]

Measurement Techniques. DC polarisation curves on freshly abraded mild steel in bulk paints were determined using a traditional 3-electrode potentiodynamic technique. A 50 ml cell employed a disc mild steel electrode (area 0.33 cm ), saturated calomel reference and platinum counter electrode. Polarisation curves were made at a scan rate of 2V/Hr between -950 to -450 mV vs see. [Pg.20]

Note 2 Cross-over concentration is defined as a range because different measurement techniques give different values. The symbol c refers usually to amount concentration, but in polymer science it is generally used for mass concentration. [Pg.53]


See other pages where Reference measurement technique is mentioned: [Pg.339]    [Pg.167]    [Pg.126]    [Pg.369]    [Pg.235]    [Pg.124]    [Pg.3]    [Pg.344]    [Pg.144]    [Pg.535]    [Pg.215]    [Pg.54]    [Pg.622]    [Pg.252]    [Pg.175]    [Pg.694]    [Pg.323]    [Pg.430]    [Pg.57]    [Pg.61]    [Pg.136]    [Pg.129]    [Pg.164]    [Pg.61]    [Pg.176]    [Pg.46]    [Pg.25]    [Pg.227]    [Pg.952]    [Pg.247]   
See also in sourсe #XX -- [ Pg.184 ]




SEARCH



Reference Techniques

Reference measurements

© 2024 chempedia.info