Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Purge connection

Mechanical connections (or disconnections) for blanking, draining, cleaning and purging connections so that maintenance activities cannot be started without first disconnecting lines... [Pg.86]

Blind temperature transmitter, poientlometric electro to pneumatic converter. 2000. Alarm contact, adjustable. 000. Air purge connection. 40. [Pg.814]

I rppene leaked into the steam system via a steam purge connection. This resulted in propane issuing from a fire-suppressant steam pinge nozzle. [Pg.748]

Fig. 5.119. Schematic drawing of an electrochemical cell for in situ NMR spectroscopy [649]. A counter electrode connection B reference electrode joint C counter electrode D platinum black working electrode E working electrode connection F purge connection... Fig. 5.119. Schematic drawing of an electrochemical cell for in situ NMR spectroscopy [649]. A counter electrode connection B reference electrode joint C counter electrode D platinum black working electrode E working electrode connection F purge connection...
S ample Analysis. The fohowing procedure is used for sample analysis (/) after sample connections are made and the sample tubing purged for 30 minutes, the tubing is connected to the sampling manifold which serves to distribute sample gas to each of the analy2ers, and should analy2ers have specific pressure... [Pg.90]

The cell head is fabricated from a 2.54-cm steel plate and has separate compartments for fluorine and hydrogen. The oudet-gas manifolds, hydrogen fluoride feed and purge lines, and electrical connections are on top of the head. The gas separation skirt is made of Monel. An insulating gasket maintains the seal between the tank and the head. The anode assembly consists of 32 carbon blades bolted onto a copper bar, each of which contains three copper conductor posts. The cathode assembly consists of three vertical, 0.6-cm parallel steep plates. The plates surround the anode assembly and are supported by three steel posts which also serve as conductors. [Pg.126]

Inasmuch as the gas hydroly2es readily, all equipment should be purged repeatedly using inert dry gas before admitting boron trifluoride. Under anhydrous conditions, carbon steel equipment is satisfactory. Stainless steel and aluminum siUcon bron2e may also be used. Stainless steel tubing is recommended for both temporary and permanent connections. [Pg.161]

Fig. 14. Self-purging system with the differential pressure (AP) transmitter located at the upper level connection. Fig. 14. Self-purging system with the differential pressure (AP) transmitter located at the upper level connection.
Material released Blow (purge) system, clean lines, before breaking when transfer lines the connection are disconnected., Minimize use of hoses AGA XK0775 CCPS G-22 CCPS G-29 FMEC 1997... [Pg.88]

Leakage from Use adequate shaft sealing (mechanical or multimill ignited by pie gas purged lip or chevron seals). Harden spark or hot shafts in seal area surface., pressure tight flexible connections and clamps on mill inlets and outlets Provide adequate fixed fire protection where appropriate CCPS G-23 CCPS G-29 NFPA 13 NFPA 15 NFPA 16... [Pg.98]

Of the instmments described only some are suitable for use outside the laboratory. Where any instrument is carried into a flammable environment it should either be certified as intrinsically safe for exposure to the flammable atmosphere or isolated from the atmosphere such as by keeping it within a purged enclosure. Any probe connected to the instmment must be separately considered as a possible ignition source. Electrometers are described in [ 1531. A more general review of electrostatic instruments is given in [ 136]. [Pg.50]

Beyond the complexities of the dispersive element, the equipment requirements of infrared instrumentation are quite simple. The optical path is normally under a purge of dry nitrogen at atmospheric pressure thus, no complicated vacuum pumps, chambers, or seals are needed. The infrared light source can be cooled by water. No high-voltage connections are required. A variety of detectors are avail-... [Pg.417]

Flashback protection is required for H2S flaring systems, either by water seal or continuous gas purge. If a water seal is used, special requirements apply to the disposal of the effluent seal water. In the case of an HjS flaring system handling a flow of HjS which in uninterrupted throughout the period that a plant is in operation, and which stops only when the producing plant is shutdown, then flashback protection is not required. However, steam or inert gas connections are required to permit purging the flare line startup and shutdown. [Pg.279]

Gas storage cabinets are designed to contain one to four gas cylinders. The cylinders are connected to a gas distribution system which is also contained in the cabinet. Very sophisticated systems are available from cabinet manufacturers. These may include automatic or semiautomatic change-over capabilities, fire sprinklers, purging systems, and gas detection systems which may include alarms and automatic shutoff. Point-of-use scrubbers may also be incorporated into the design, depending on the gas being used (see Fig. 10.43). [Pg.895]

The concept of local age and local purging flow rate was introduced in refs. 39 and 41. These parameters were first studied in connection with CFD in refs. 32 and 42. Local age at a point is understood to mean the time that... [Pg.1046]

Vent and purge lines Operation omitted (08) Operation incomplete (09) Lines not fully purged 4.2.4 Failure of operator to detect pressure in lines could lead to leak when tanker connections broken... [Pg.219]


See other pages where Purge connection is mentioned: [Pg.313]    [Pg.333]    [Pg.224]    [Pg.154]    [Pg.760]    [Pg.704]    [Pg.702]    [Pg.609]    [Pg.599]    [Pg.290]    [Pg.292]    [Pg.914]    [Pg.248]    [Pg.1219]    [Pg.343]    [Pg.376]    [Pg.313]    [Pg.333]    [Pg.224]    [Pg.154]    [Pg.760]    [Pg.704]    [Pg.702]    [Pg.609]    [Pg.599]    [Pg.290]    [Pg.292]    [Pg.914]    [Pg.248]    [Pg.1219]    [Pg.343]    [Pg.376]    [Pg.90]    [Pg.395]    [Pg.277]    [Pg.394]    [Pg.105]    [Pg.211]    [Pg.369]    [Pg.492]    [Pg.508]    [Pg.1736]    [Pg.29]    [Pg.552]    [Pg.253]    [Pg.200]    [Pg.172]    [Pg.479]    [Pg.139]   
See also in sourсe #XX -- [ Pg.313 ]




SEARCH



Purgatives

Purge

© 2024 chempedia.info