In continuous production, product is inspected by taking samples from the line which are then examined while the line continues producing product. In such cases you will need a means of holding product produced between sampling points until the results of the tests and inspections are available. You will also need a means of releasing product when the results indicate that the product is acceptable. So a Product Release Procedure or Held Product Procedure may be necessary. The standard implies, however, that if you have released product under positive recall procedures you do not need to hold product while in-process inspection and tests are performed. The reference to clause 4.10.3(a) is also ambiguous because the inspections and tests carried out in accordance with the quality plan or documented procedures may not cover those necessary to verify product on receipt into the plant. It would be wise to hold any product until you have... [Pg.385]

Control of non-conforming product - Establish procedures for rework, reject, or release under concession... [Pg.232]

Quality control is that part of good manufacturing practice concerned with sampling, specifications, and testing. Its organization, documentation, and release procedures ensure that the necessary and relevant tests are actually carried out, that materials are not released for use and products released for sale or supply, until their quality has been judged to be satisfactory. [Pg.42]

A report from a 1990 ASCPT/DIA/APS/FDA-sponsored workshop entitled 7n vitro/In vivo Testing and Correlation for Oral Controlled/Modified Release Dosage Forms (1990) concluded that, while the science and technology may not always permit meaningful IVIVC, the development of an IVIVC was an important objective on a product-by-product basis. Procedures for development, evaluation, and application of an IVIVC were described. Validation of dissolution specifications by a bioequivalence study involving two batches of product with dissolution profiles at the upper and lower dissolution specifications was suggested. [Pg.448]

Only upon the successful completion of the integration testing and documentation review should product release be authorized. Once an application software program is released, it should be placed under formal configuration/ version control, and any revisions must follow the requirements of a change control procedure. [Pg.607]

Some acidic fruit juices are not fully appreciated by consumers and are to be de-acidified by sugar or alkali addition. Whereas the use of CaCC>3 is not recommended since the release of C02 induces foaming and poor pH control, that of Ca(OH)2 may cause some precipitation problems in the final product. Such procedures may be limited by legislation and, even if they have so far conferred no sensory dislike, may involve chemophobic reactions in the general consumer, who is averse to any chemical addition in natural products (Vera et al., 2003). [Pg.321]

Systems that define the ability to document and trace modifications to the current product or process Release procedures... [Pg.359]

Design Qualification (DQ) is the first validation element of a new facility system or equipment, where adherence to the user s specifications and to GMP rules is demonstrated. Installation Qualification (IQ) follows with the verification of adequacy of the area, installation of equipment pipelines, utilities, instrumentation, and conformity of the material used to the project specifications. At the Operational Qualification (OQ) phase, carried out after installation of all equipment, it is verified whether the system, when in operation, complies with the acceptance criteria defined in the validation plan. Once the OQ phase is successfully finalized it is possible to proceed with the calibration procedures, operation and cleaning, operator training, and preventive maintenance program. After IQ and OQ are concluded, it is time for the Performance Qualification (PQ), with the aim of verifying that what was designed, built, and operated results in a product that meets the expected specifications. Production and QC personnel are specially trained for these assessments. The tests can be done with the product of interest or a placebo, and are related to all operations, from raw material reception to product release (EC, 2001). [Pg.359]

A facile synthesis of enantiopure tricyclic furyl derivatives employing 4-vinyl-2,3-dihydrofuran via Diels-Alder cycloaddition reaction was reported <02TL7983>. A new capture-ROMP-release procedure for chromatography-free purification of N-hydroxysuccinimide Mitsunobu reactions was reported by Hanson, who used a Mitsunobu reaction to capture a variety of alcohols onto a norbomenyl A-hydroxysuccinirmde monomer. Treatment of this monomer under ROM-polymerization then generated a water-soluble polymer that was readily separable from other by-products. Subsequent reaction with hydrazine was utilized to release the O-alkylhydroxylamines in good purity from the water-soluble polymer <020L1007>. [Pg.176]

Secondary metabolites produced by plant cell culture are commonly accumulated in the cells. With few exceptions such as Capsicum frutescens, Thalictrum minus (9) and Vanilla planifolia (Knorr, D. and Romagnoli, L., Univ. of Delaware, unpublished data) cultures, which release valuable compounds such as capsaicin, berberine and vanillin, respectively, into the medium, procedures to induce product release are required to develop continuous production processes. Reported permeabilization methods include treatment with dimethylsulfoxide (DMSO), isopropanol, toluene, phenethyl alcohol or chloroform (9, 28). But as Fontanel and Tabata (9) pointed out, such treatments with organic solvents are severe and other methods of permeabilization need to be developed. [Pg.72]

The first publication about the computer translation of chemical names was published by Garfield in 1961. In that article, he described the conversion of names into chemical formulas and initiated the path toward N2S algorithm development.45 Developments in 1967 at CAS provided internal procedures for the automatic conversion of CAS names into chemical diagrams.46 47 The first commercially available software program was CambridgeSoft s Name=Struct released in 1999,48 now patented,49 which was followed shortly by ACD/Labs ACD/Name to Structure product released in 2000.50 Two more commercial products are available Chemlnnovation s NameExpert51 and... [Pg.28]

Failure to maintain procedures to ensure that the device design is correctly translated into production specifications. For example, the [redacted] software source code version 1.6 did not go through a formally documented design transfer process. The source code s electronic file transfer to the master chip before production release was not documented and the approved sonrce code version 1.6 (hardcopy or electronic file) was not retained nnder Docnment Controls. [Pg.920]

Sampling procedures provide an overview of the type of sampling that is conducted. They need to state, for instance, whether the samples are taken for process control, for product release, or for environmental reasons. The procedures alert us to what particulars to look for in the field when we do the walk-through. We can ask those who sample how they were trained to sample and if they are familiar with the procedures. We can compare what the procedures state to what we observe and then note any discrepancies. It is not uncommon to find differences between what is written and what is practiced. These differences may have important economic, safety, or environmental consequences. [Pg.77]

The first synthesis reported by Merrifield produced the desired tetrapeptide (Leu-Ala-Gly-Val).f l Amino acids, dipeptides, and tripeptides were all detected in the crude product released from the resin. Through continued improvements of the method, the high speed of the amino acid incorporation and automation, the solid-phase peptide synthetic methodology has become the method of choice for most laboratories synthesizing peptides. Shortly after the introduction of the solid-phase procedure it was used to synthesize insulin. This impressive achievement awakened the biochemical community to the promise of synthetic chemistry and initiated a period in which large numbers of peptide analogues were prepared and analyzed. [Pg.8]

Authorized procurement and release procedures should be in place, to ensure that appropriate pharmaceutical products are sourced from approved suppliers and distributed by approved entities. [Pg.188]


See other pages where Product release procedure is mentioned: [Pg.87]    [Pg.284]    [Pg.87]    [Pg.284]    [Pg.316]    [Pg.99]    [Pg.485]    [Pg.83]    [Pg.20]    [Pg.66]    [Pg.98]    [Pg.341]    [Pg.49]    [Pg.374]    [Pg.398]    [Pg.381]    [Pg.168]    [Pg.189]    [Pg.817]    [Pg.17]    [Pg.49]    [Pg.84]    [Pg.16]    [Pg.126]    [Pg.734]    [Pg.2260]    [Pg.822]    [Pg.1532]    [Pg.81]    [Pg.90]    [Pg.99]    [Pg.170]    [Pg.416]   