Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Flow regulation

Figure 14.4 Schematic diagram of the cliromatographic system used for the analysis of very low concentrations of sulfur compounds in ethene and propene CP, pressure regulator CF, flow regulator SL, sanrple loop R, restriction to replace column 2 VI, injection valve V2, tliree-way valve to direct the effluent of column 1 to either column 2 or the restriction column 1, non-polar- capillary column column 2, tliick-film capillary column SCD, sulfur chemiluminescence detector FID, flanre-ionization detector. Figure 14.4 Schematic diagram of the cliromatographic system used for the analysis of very low concentrations of sulfur compounds in ethene and propene CP, pressure regulator CF, flow regulator SL, sanrple loop R, restriction to replace column 2 VI, injection valve V2, tliree-way valve to direct the effluent of column 1 to either column 2 or the restriction column 1, non-polar- capillary column column 2, tliick-film capillary column SCD, sulfur chemiluminescence detector FID, flanre-ionization detector.
Nilsson C, Reidy CA, Dynesius M et al (2005) Fragmentation and flow regulation of the world s large river systems. Science 308 405 08... [Pg.37]

Dynesius M, Nilsson C (1994) Fragmentation and flow regulation of river systems in the Northern third of the World. Science 266 753-762... [Pg.37]

Keefer, B.G. and D.G. Doman, Flow Regulated Pressure Swing Adsorption System, U.S. Patent No. RE38,493E, 2004. [Pg.319]

Ward JV, Stanford JA (1995) Ecological connectivity in alluvial river ecosystems and its disruption by flow regulation. Regulated Rivers Res Manag 11 105-119... [Pg.44]

Precautions should be taken to avoid flashbacks. Flashbacks result from improperly mixed fuel and air, such as when the flow regulators on the instrument are improperly set or when air is drawn back through the drain line of the premix burner. Manuals supplied with the instruments when they are purchased give more detailed information on the subject of safety. [Pg.258]

The spatula with a funnel and flow regulator can be used for weighing into very small crucibles or narrow-necked containers. The flow regulator is adjustable and holds back coarse granules assuring an even flow of fine substance. [Pg.88]

The methods of flow regulation and control are particularly critical. [Pg.140]

Flow regulation mainly concerns residual flow and hydropeaking. Residual flow reaches are affected by the lack of natural flow patterns and by decreased water... [Pg.214]

Fishes in Alpine floodplains are limited to cold stenothermic species such as the brown trout, and many alpine lakes are currently stocked to sustain the fishery. Water abstraction and flow regulation severely constrain the management of the fishery in Alpine waters today. The effects of climate change on the fishery are difficult to predict but could facilitate the upward migration of more cool water fishes in the future. The implications of these new fishes on aquatic food webs are not certain but could be substantial. [Pg.218]

Flow regulators at the column head should not have parts that would contribute to background. A simple needle valve is sufficient. [Pg.264]

Even the sample loop should be controlled to the same pressure as the column side to minimize pressure upsets when switching the valve. Frazer et al. (9) found that pressure and flow regulation on all inlets as well as the appropriate micrometering valves (variable restrictors) used to dynamically balance the carrier gas flow and pressure allowed them to switch a 20 foot by 1/8-inch column in or out of a multivalve, multicolumn system with a resulting change in the baseline signal of less than 5 iV. [Pg.305]

Temperature programming also has demands on other parts of the chromatographic system. These have already been discussed in the areas of carrier gas purity, flow regulation, and injection systems. In addition, columns must be stable at the top temperature of the program ramp and should have a low vapor pressure (low bleed). [Pg.332]


See other pages where Flow regulation is mentioned: [Pg.44]    [Pg.234]    [Pg.678]    [Pg.878]    [Pg.238]    [Pg.278]    [Pg.73]    [Pg.74]    [Pg.22]    [Pg.199]    [Pg.224]    [Pg.42]    [Pg.16]    [Pg.121]    [Pg.106]    [Pg.148]    [Pg.64]    [Pg.183]    [Pg.6]    [Pg.194]    [Pg.200]    [Pg.200]    [Pg.201]    [Pg.214]    [Pg.248]    [Pg.78]    [Pg.44]    [Pg.107]    [Pg.339]    [Pg.295]    [Pg.25]    [Pg.450]    [Pg.271]    [Pg.600]   
See also in sourсe #XX -- [ Pg.313 ]

See also in sourсe #XX -- [ Pg.40 ]




SEARCH



Blood flow regulation

Carrier gas and flow regulation

Cerebral blood flow regulation

Gas Pressure Regulator and Flow Meter

Metabolic pathway/metabolite flow regulation

Metabolite flow regulation

Regulation of Blood Flow by HbSNO

Regulation of Energy Flow and Heat Production

Regulation of blood flow through tissues

Regulation of thermal conditions under fast chemical reactions in turbulent flows

© 2024 chempedia.info