Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Potential standard system

Many microorganisms represent attractive potential production systems for therapeutic proteins. They can usually be cultured in large quantities, inexpensively and in a short time, by standard... [Pg.105]

It is used orally for intestinal candidiasis, topically for oral, vaginal and cutaneous candidiasis and hospital treatment of progressive and potentially fatal systemic fungal infections. It is the gold standard of antifungal therapy. Flucytosine has supraadditive action with amphotericin B if the fungi is sensitive to both. It is also potentiated by rifampicin and minocycline. [Pg.343]

When dehydration occurs as a consecutive reaction, its effect on polarographic curves can be observed only, if the electrode process is reversible. In such cases, the consecutive reaction affects neither the wave-height nor the wave-shape, but causes a shift in the half-wave potentials. Such systems, apart from the oxidation of -aminophenol mentioned above, probably play a role in the oxidation of enediols, e.g. of ascorbic acid. It is assumed that the oxidation of ascorbic acid gives in a reversible step an unstable electroactive product, which is then transformed to electroinactive dehydroascorbic acid in a fast chemical reaction. Theoretical treatment predicted a dependence of the half-wave potential on drop-time, and this was confirmed, but the rate constant of the deactivation reaction cannot be determined from the shift of the half-wave potential, because the value of the true standard potential (at t — 0) is not accessible to measurement. [Pg.42]

Chloroaluminate Systems. In case of chloroaluminate ionic liquids, the potential of an aluminum electrode immersed in the acidic ionic liquids which contain AICI3 at more than 50 mol% is usually assumed as the potential standard. [Pg.32]

Modifications to Electron Beam System. The retarding potential field was introduced into our vector scan system by attaching a O-to-20 KV, 2 mAmp external power supply to the wafer holder. This is shown diagrammatically in Figure 2. Whereas the wafer is at ground potential in the standard system, in our modified system the net potential at the wafer can vary from 0 to 20 KV. Thus, the electrons are accelerated down the column at a standard operating potential, exit the final lens and are retarded by the variable electrostatic field near the wafer plane. [Pg.351]

Aller, L. Bennett, T. Lehr, J Petty, R. "DRASTIC A Standardized System for Evaluating Groundwater Pollution Potential using Hydrogeologic Settings" USEPA, Office of Research and Development Washington, D.C., 1985 384 pp. [Pg.104]

Systems based on standard single trip containers. Potentially any. Systems often rely on presence of a foil seal so as to remain closed while an alternative closure is fitted. Wisdom system. Contents withdrawn in measured amounts. Container inverted in system. Can also be used with keg type containers. [Pg.55]

This paper presents a standardized system which can be used to evaluate the ground-water pollution potential of any hydrogeologic setting in the United States. The system has been designed to use information which is available through a variety... [Pg.143]

This paper summarizes the efforts to produce a standardized system to evaluate ground water pollution potential. The project was designed to span two years. During the first year, the methodology was developed with the help of an advisory committee. [Pg.158]

A Standardized System for Evaluating Ground Water Pollution Potential Using Hydrogeologic Settings" USEPA No. 600/2-85/... [Pg.160]

There are commercial blast mitigation devices available which are potentially applicable to the destruction of recovered CWM. Nabco Incorporated is a manufacturer of containment vessels. Their standard system is transportable and qualified to contain 10 pounds of C4. Nabco also has a new vessel designed to withstand 26 pounds of C4. Shielding Technologies, Inc. and Weatherly-Dynasafe also manufacture comparable systems. The challenge involved with utilizing these systems lies in assured destruction of the explosive and the subsequent detoxification of the containment vessel. [Pg.85]

A test of the measurement accuracy of zeta potential is much more complicated because there is no zeta potential standard for concentrated systems. The absence of electroacoustic theory for concentrated systems creates additional complexity. Our experience is that CVC makes it possible to measure with almost the same accuracy as micro-electrophoresis. [Pg.194]

Aller, L, et al. (1985). Drastic, A Standard System for Evaluating Ground Water Pollution Potential Using Hydrogeologic Setting, USEPA, R. S. Kerr Environmental Research Laboratory, EPA/60012-851018. Ada, OK. [Pg.241]

The health rating is provided on the left at the 9 o clock position and is colored blue. The flammability rating is provided at the top or 12 o clock position and is colored red. The reactivity hazard is provided on the right at the 3 o clock position and is colored yellow. The relative rankings for each hazard are indicated in each quadrant. Special hazard identifiers are provided in the bottom quadrant at the 6 o clock position, which is usually white. Special hazard qualifiers generally include radioactivity, explosives, corrosive, water reactive, oxidizer, etc. The NFPA fire hazard identification scheme is somewhat limited as it only identifies relative potential hazards with the individual material. It does not identify the material itself or all of its potential reactions with other materials. See Figure C.3 for a depiction of this placard. See also Chemical Hazard Label Hazardous Materials Identification System (HMIS ) NFPA 704, Standard System for the Identification of the Hazards of Materials for Emergency Response. [Pg.126]

Prospective flax fiber tests include a standard test method for flax fiber bundle strength and elongation similar to the Stelometer, fiber length and distribution, fineness distribution via image analysis, wax content via NIR, density measurement, and numerous flax mat characterization tests. Prior work has indicated that NIR spectroscopy has potential for determining wax content in flax fibers (Sohn et al. 2006). Potential standards could exist for farmers to predict fiber content in stems in the field by near-infrared spectroscopy (Barton et al. 2002). The Composites Innovation Center (QC) in Winnipeg is working on a system to characterize flax fiber mats and subsequent composites. [Pg.80]

In general, the Ln + ions can be considered to be essentially redox inactive under most conditions. Halfwave potentials are available in nonaqueous solvents and, as can be seen in Table 5, they are significantly solvent dependent. The half-wave potentials are directly proportional to the reduction potential. The values are quoted relative to bis(biphenylchromium(T))/(0) as this can be used as an internal standard that eliminates problems with unknown junction potentials in systems where the reference electrode is in a different solvent. [Pg.39]


See other pages where Potential standard system is mentioned: [Pg.293]    [Pg.263]    [Pg.293]    [Pg.263]    [Pg.1368]    [Pg.148]    [Pg.149]    [Pg.77]    [Pg.230]    [Pg.99]    [Pg.128]    [Pg.101]    [Pg.30]    [Pg.444]    [Pg.225]    [Pg.609]    [Pg.518]    [Pg.107]    [Pg.146]    [Pg.838]    [Pg.278]    [Pg.63]    [Pg.1003]    [Pg.463]    [Pg.301]    [Pg.1397]    [Pg.43]    [Pg.510]    [Pg.157]   
See also in sourсe #XX -- [ Pg.293 ]




SEARCH



Potential standard

Potentials, standardization

Standard system

© 2024 chempedia.info