Preston, R, The Theory and Design of Plate Glass Polishing Machines," Society of Glass Technology—Journal, Vol. 11,No. 42,1927,pp. 214-256. [Pg.268]

TABLE III. REPRESENTATIVE SPHERE AND TORIC POLISHING MACHINE CHARACTERISTICS, 1930 - 1980... [Pg.99]

Table III illustrates the progress which has been made in polishing machines over the last fifty years. Table III illustrates the progress which has been made in polishing machines over the last fifty years.
The wafers are Chen physically mounted Co a mechanical polishing machine, using a sodium bicarbonate, 5% chlorine, water and colloidal silica slurry. [Pg.348]

Floors should be scrubbed and polished using a floor-polishing machine. No wax is to be used. [Pg.230]

Preston FW. The theory and design of plate glass polishing machines. J Soc Glass Technol 1927 11 214-256. [Pg.168]

Chemical Mechanical Polishing (CMP) has emerged over the last decade as an enabling technology within the semiconductor industry. It has allowed the widespread application of high density multilevel interconnects, and has also found use in applications such as shallow trench isolation (STI). There will soon be almost 2000 polishing machines being used for CMP world wide. [Pg.73]

In all of the above discussion, the focus has been entirely on the local conditions where the point on the wafer, an abrasive particle and the pad meet. In practice, the system is substantially more complicated, with much effort directed toward producing a clean, uniform and manufacturable process. Thus the polishing machine usually produces a complex wafer motion, including wafer rotation, which averages polish conditions which vary with position across the wafer. In addition, the pad and the asperities created also have position dependence for which complex wafer paths and conditioning procedures are used. These useful and necessary techniques enhance the performance of the technology but also obscure the behavior of individual polishing events. [Pg.76]

Ans. Beriberi was once thought to be an infectious disease. It is characterized by neurological disorders. The disease was unknown until the early 19th century when rice polishing machines were invented. These machines removed the brown outer hull of the rice seed. The cure was discovered when the addition of the outer hull to the diet completely reversed the symptoms. The critical component of rice hulls is thiamin, which is the cofactor in decarboxylations. The blood of those having the deficiency contains elevated levels of pyruvate, which must be decarboxylated in order to enter the TCA cycle. [Pg.490]

The CMP process has a higher possibility of defects than other processes because it uses abrasive in slurry. It especially causes scratches therefore, controlling the defects is important. To repress scratches attributed to slurry, filter is generally placed at the supply system, circulation loop, and point of use (POU). These factors can be mixed diversely according to the polishing machine s structure or processing condition selection. However, other materials are also influenced because of the correlation when a factor... [Pg.7]

We have run experiments where only high pH water is supplied in the polishing machine and shown that without the presence of some colloidal silica, the removal rate goes to nil. This would imply that the aUcaU silicate salts from a somewhat protective skin over the siUcon surface. Likewise, the lower the pH, the lower the removal rate. One further proof that a chemical reaction is involved is the... [Pg.167]

Pressure, temperature, and flow rate are considered together here as they are all interconnected in their effect on most polishing machines. When pressure is increased. [Pg.167]

This test is conducted on coarse aggregates that are used for surfacing mixes. The PSV test determines the resistance of the coarse aggregate to the polishing action of vehicle tyres. The test consists of two parts in the first part, test specimens are subjected to a polishing action in an accelerated polishing machine. In the second part of the test, the state of polish reached by each specimen is measured using the Pendulum tester apparatus. The PSV is then calculated from the friction determinations. [Pg.69]

Approximately 36 to 46 aggregate particles of size 7.2/10 mm are carefully placed in a single layer in a mould with their flattest surface lying on the bottom. The interstices between the aggregates are filled with fine sand. The quantity of sand used is such that only three quarters of the depth of the interstices is filled. Then, the mould is in-filled with an epoxy resin and any surplus is removed with a spatula. After the resin has hardened, the specimen is cleaned thoroughly to remove any sand and is transferred to the polishing machine. [Pg.69]


See other pages where Polishing machine is mentioned: [Pg.157]    [Pg.871]    [Pg.770]    [Pg.770]    [Pg.243]    [Pg.135]    [Pg.169]    [Pg.378]    [Pg.826]    [Pg.226]    [Pg.226]    [Pg.147]    [Pg.617]    [Pg.617]    [Pg.617]    [Pg.57]    [Pg.149]    [Pg.826]    [Pg.16]    [Pg.449]    [Pg.174]    [Pg.4]    [Pg.4]    [Pg.241]    [Pg.1474]    [Pg.167]    [Pg.341]    [Pg.178]    [Pg.957]    [Pg.524]    [Pg.374]    [Pg.79]   