Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

PH-values

The effect is more than just a matter of pH. As shown in Fig. XV-14, phospholipid monolayers can be expanded at low pH values by the presence of phosphotungstate ions [123], which disrupt the stmctival order in the lipid film [124]. Uranyl ions, by contrast, contract the low-pH expanded phase presumably because of a type of counterion condensation [123]. These effects caution against using these ions as stains in electron microscopy. Clearly the nature of the counterion is very important. It is dramatically so with fatty acids that form an insoluble salt with the ion here quite low concentrations (10 M) of divalent ions lead to the formation of the metal salt unless the pH is quite low. Such films are much more condensed than the fatty-acid monolayers themselves [125-127]. [Pg.557]

Fig. XV-14. Surface pressure-area isotherms at 298 K for a DPPC monolayer on phos-photungstic acid (10 Af) at the pH values shown with 10 A/ NaCl added. (From Ref. 123.)... Fig. XV-14. Surface pressure-area isotherms at 298 K for a DPPC monolayer on phos-photungstic acid (10 Af) at the pH values shown with 10 A/ NaCl added. (From Ref. 123.)...
One potentially powerfiil approach to chemical imaging of oxides is to capitalize on the tip-surface interactions caused by the surface charge induced under electrolyte solutions [189]. The sign and the amount of the charge induced on, for example, an oxide surface under an aqueous solution is detenuined by the pH and ionic strength of the solution, as well as by the isoelectric point (lEP) of the sample. At pH values above the lEP, the charge is negative below this value. [Pg.1714]

The most often used subphase is water. Mercury and otlier liquids [12], such as glycerol, have also occasionally been used [13,14]. The water has to be of ultrapure quality. The pH value of tire subphase has to be adjusted and must be controlled, as well as tire ion concentration. Different amphiphiles are differently sensitive to tliese parameters. In general it takes some time until tire whole system is in equilibrium and tire final values of pressure and otlier variables are reached. Organic contaminants cannot always be removed completely. Such contaminants, as well as ions, can have a hannful influence on tire film preparation. In general, all chemicals and materials used in tire film preparation have to be extremely pure and clean. [Pg.2611]

FIGURE 27 2 The titration curve of glycine At pH values less than pKs H3NCH2CO2H is the major species present At pH values between pKs and pK z the principal species is the zwitter... [Pg.1117]

Table 8.18 pH Values for Buffer Solutions in Alcohol-Water Solvents at 25°C 8.109... [Pg.828]

Table 8.19 pH Values of Biological and Other Buffers for Control Purposes 8.110... [Pg.828]

TABLE 8.16 Composition and pH Values of Buffer Solutions (Continued)... [Pg.935]

The pH value is defined for an aqueous solution in an operational (arbitrary but reproducible) manner according to the Bates-Guggenheim convention ... [Pg.942]

The pH of an acidic solution, therefore, must be less than 7.00. A basic solution, on the other hand, will have a pH greater than 7.00. Figure 6.3 shows the pH scale along with pH values for some representative solutions. [Pg.143]

Calibrating the electrode presents a third complication since a standard with an accurately known activity for H+ needs to be used. Unfortunately, it is not possible to calculate rigorously the activity of a single ion. For this reason pH electrodes are calibrated using a standard buffer whose composition is chosen such that the defined pH is as close as possible to that given by equation 11.18. Table 11.6 gives pH values for several primary standard buffer solutions accepted by the National Institute of Standards and Technology. [Pg.492]

Polymers in Solution. Polyacrylamide is soluble in water at all concentrations, temperatures, and pH values. An extrapolated theta temperature in water is approximately —40° C (17). Insoluble gel fractions are sometimes obtained owing to cross-link formation between chains or to the formation of imide groups along the polymer chains (18). In very dilute solution, polyacrylamide exists as unassociated coils which can have an eUipsoidal or beanlike stmcture (19). Large aggregates of polymer chains have been observed in hydrolyzed polyacrylamides (20) and in copolymers containing a small amount of hydrophobic groups (21). [Pg.139]

Acid-Base Behavior. The relative acidity-basicity of the filler, generally determined by measuring the pH value of a slurry of a specific mass of filler in 100 mL of deionized water, can influence the behavior of a filler in some systems. For example, the curing behavior of some elastomers is sensitive to the pH value of carbon black. [Pg.367]

The basic flow sheet for the flotation-concentration of nonsulfide minerals is essentially the same as that for treating sulfides but the family of reagents used is different. The reagents utilized for nonsulfide mineral concentrations by flotation are usually fatty acids or their salts (RCOOH, RCOOM), sulfonates (RSO M), sulfates (RSO M), where M is usually Na or K, and R represents a linear, branched, or cycHc hydrocarbon chain and amines [R2N(R)3]A where R and R are hydrocarbon chains and A is an anion such as Cl or Br . Collectors for most nonsulfides can be selected on the basis of their isoelectric points. Thus at pH > pH p cationic surfactants are suitable collectors whereas at lower pH values anion-type collectors are selected as illustrated in Figure 10 (28). Figure 13 shows an iron ore flotation flow sheet as a representative of high volume oxide flotation practice. [Pg.50]

At Lake Texcoco, Mexico, bicarbonate is available in the alkaline waters from soda ash [497-19-8] (sodium carbonate) deposits (see Alkali and CHLORINE products). This supply of carbon is adequate for growing Spirulina maxima which tolerates alkaline pH values in the range 9—11 (37,38). Combustion gases have been used to grow this organism, but this carbon source is not available in many regions (49). [Pg.464]

Eor purposes of product identification and quaUty control it is useful not only to employ the abovementioned analytical methods but also to measure physical constants such as the density, refractive index, melting point, and pH value of the material. [Pg.509]

Purified hGH is a white amorphous powder in its lyophilized form. It is readily soluble (concentrations >10 mg/mL) in dilute aqueous buffers at pH values above 7.2. The isoelectric point is 5.2 (3) and the generally accepted value for the extinction coefficient at 280 nm is 17,700 (Af-cm) (4),... [Pg.195]

Accuracy and Interpretation of Measured pH Values. The acidity function which is the experimental basis for the assignment of pH, is reproducible within about 0.003 pH unit from 10 to 40°C. If the ionic strength is known, the assignment of numerical values to the activity coefficient of chloride ion does not add to the uncertainty. However, errors in the standard potential of the cell, in the composition of the buffer materials, and ia the preparatioa of the solutioas may raise the uacertaiaty to 0.005 pH unit. [Pg.465]

Other problems occur in the measurement of pH in unbuffered, low ionic strength media such as wet deposition (acid rain) and natural freshwaters (see Airpollution Groundwatermonitoring) (13). In these cases, studies have demonstrated that the principal sources of the measurement errors are associated with the performance of the reference electrode Hquid junction, changes in the sample pH during storage, and the nature of the standards used in caHbration. Considerable care must be exercised in all aspects of the measurement process to assure the quaHty of the pH values on these types of samples. [Pg.466]

The activity of the hydrogen ion is affected by the properties of the solvent in which it is measured. Scales of pH only apply to the medium, ie, the solvent or mixed solvents, eg, water—alcohol, for which the scales are developed. The comparison of the pH values of a buffer in aqueous solution to one in a nonaqueous solvent has neither direct quantitative nor thermodynamic significance. Consequently, operational pH scales must be developed for the individual solvent systems. In certain cases, correlation to the aqueous pH scale can be made, but in others, pH values are used only as relative indicators of the hydrogen-ion activity. [Pg.467]


See other pages where PH-values is mentioned: [Pg.606]    [Pg.2786]    [Pg.118]    [Pg.561]    [Pg.1117]    [Pg.1298]    [Pg.828]    [Pg.850]    [Pg.933]    [Pg.934]    [Pg.1166]    [Pg.151]    [Pg.170]    [Pg.284]    [Pg.492]    [Pg.307]    [Pg.37]    [Pg.251]    [Pg.486]    [Pg.389]    [Pg.207]    [Pg.207]    [Pg.52]    [Pg.53]    [Pg.465]   
See also in sourсe #XX -- [ Pg.2 , Pg.5 ]

See also in sourсe #XX -- [ Pg.130 ]

See also in sourсe #XX -- [ Pg.2 , Pg.5 ]

See also in sourсe #XX -- [ Pg.46 , Pg.56 , Pg.264 , Pg.305 , Pg.307 ]

See also in sourсe #XX -- [ Pg.2 , Pg.254 ]

See also in sourсe #XX -- [ Pg.4 , Pg.23 ]

See also in sourсe #XX -- [ Pg.319 ]

See also in sourсe #XX -- [ Pg.270 , Pg.274 ]

See also in sourсe #XX -- [ Pg.208 , Pg.295 , Pg.306 , Pg.307 , Pg.308 , Pg.309 , Pg.310 , Pg.312 , Pg.313 , Pg.314 , Pg.315 , Pg.320 , Pg.780 , Pg.1093 , Pg.1278 , Pg.1306 , Pg.1463 , Pg.1511 ]

See also in sourсe #XX -- [ Pg.741 , Pg.742 ]




SEARCH



Acids and pH Value

At various pH values

Blood pH value

Buffer Solutions Giving Round Values of pH at

Calculations of pH Values in Aqueous Solutions

Changes in pH value

Eluant concentration and pH value

Eluent Concentration and pH Value

Eluents concentration and pH value

Gastric pH value

Hydrogen ion and pH value

Independence of pH values

Ions at various pH values

Natural waters, pH values

PH and pK values

PH value indicators

PH value of blood

PH value of soil

PH value of the isoelectric point

PH value of water

PH value solvent

PH values buffer

PH values, soil

Passivity of Aluminium and pH Values

Reference Value pH Standard

Sample pH value

The pH value, buffering and neutralization capacity of water

Typical pH Values of Biological Materials

Typical pH Values of Biological Materials and Foods

Variation of pH Value

Water pH values

© 2024 chempedia.info