In order to define the r), - and r 2-exponents, it is necessary to dispose a second equation, besides relation (31) for the evaluation of r.-radius, and relation (27) for the definition of the difference (T t —ri2). For this purpose we used the values of the composite moduli evaluated for various particle-volume fractions of iron-epoxy particulates determined experimentally and given in Ref.I4>. [Pg.168]

In the evaluation of toxic characteristics of an inhalable environmental chemical (e.g., carbon monoxide, volatile chemical, or aerosol/particulate), determination of acute inhalation toxicity is an initial study step. It provides information on health hazards likely to arise from short-term exposure by inhalation. Data from an acute test help to establish a dose regimen in subchronic (and other) studies, and may provide additional information on a chemical s mode of toxic action. [Pg.477]

The particulate class represents particles or droplets which more or less rapidly settle out of air, and is also the easiest class to measure. For a source particulate determination, that is, if the particulates in the flue gases of a chimney or exhaust gases of a vent stack are to be sampled, then special holes are required in the ductwork. Probes with associated equipment and a means of reaching the sampling holes are necessary. More details of this procedure are given in connection with aerosol determination. [Pg.37]

Solid-Phase Extractions In a solid-phase extraction the sample is passed through a cartridge containing solid particulates that serve as the adsorbent material. For liquid samples the solid adsorbent is isolated in either a disk cartridge or a column (Figure 7.17). The choice of adsorbent is determined by the properties of the species being retained and the matrix in which it is found. Representative solid adsorbents... [Pg.212]

This experiment describes the construction of an air sampler using an aquarium pump, a flow meter, a filter holder, and bottles that serve as traps for analytes. Applications include the determinations of SO2, NO2, HCHO, and suspended particulate matter. [Pg.225]

Two simple air samplers are described as well as their use for determining particulates in air. [Pg.225]

A gravimetric method in which the mass of a particulate analyte is determined following its separation from its matrix. [Pg.234]

Finally, in particulate gravimetry the analyte is determined following its removal from the sample matrix by filtration or extraction. The determination of suspended solids is one example of particulate gravimetry. [Pg.234]

Gravimetric methods based on precipitation or volatilization reactions require that the analyte, or some other species in the sample, participate in a chemical reaction producing a change in physical state. For example, in direct precipitation gravimetry, a soluble analyte is converted to an insoluble form that precipitates from solution. In some situations, however, the analyte is already present in a form that may be readily separated from its liquid, gas, or solid matrix. When such a separation is possible, the analyte s mass can be directly determined with an appropriate balance. In this section the application of particulate gravimetry is briefly considered. [Pg.262]

Extraction Eiltering limits particulate gravimetry to solid particulate analytes that are easily separated from their matrix. Particulate gravimetry can be extended to the analysis of gas-phase analytes, solutes, and poorly filterable solids if the analyte can be extracted from its matrix with a suitable solvent. After extraction, the solvent can be evaporated and the mass of the extracted analyte determined. Alternatively, the analyte can be determined indirectly by measuring the change in a sample s mass after extracting the analyte. Solid-phase extractions, such as those described in Ghapter 7, also may be used. [Pg.263]

Total airborne particulates are determined using a high-volume air sampler equipped with either cellulose fiber or glass fiber filters. Samples taken from urban environments require approximately 1 h of sampling time, but samples from rural environments require substantially longer times. [Pg.264]

When the analyte is already present in a particulate form that is easily separated from its matrix, then a particulate gravimetric analysis may be feasible. Examples include the determination of dissolved solids and the determination of fat in foods. [Pg.266]

The %w/w fat in candy bars is determined by an indirect particulate gravimetric analysis. Supercritical GO2 is used to extract the fat from the sample, and the change in the sample s weight is used to determine the fat content. [Pg.266]

Accuracy Under normal conditions relative errors of 1-5% are easily obtained with UV/Vis absorption. Accuracy is usually limited by the quality of the blank. Examples of the type of problems that may be encountered include the presence of particulates in a sample that scatter radiation and interferents that react with analytical reagents. In the latter case the interferant may react to form an absorbing species, giving rise to a positive determinate error. Interferents also may prevent the analyte from reacting, leading to a negative determinate error. With care, it maybe possible to improve the accuracy of an analysis by as much as an order of magnitude. [Pg.409]

The speciation scheme of Batley and Florence requires eight measurements on four samples. After removing insoluble particulates by filtration, the solution is analyzed for the concentration of anodic stripping voltammetry (ASV) labile metal and the total concentration of metal. A portion of the filtered solution is passed through an ion-exchange column, and the concentrations of ASV metal and total metal are determined. A second portion of the filtered solution is irradiated with UV light, and the concentrations of ASV metal... [Pg.539]

Source sampling of particulates requites isokinetic removal of a composite sample from the stack or vent effluent to determine representative emission rates. Samples are coUected either extractively or using an in-stack filter EPA Method 5 is representative of extractive sampling, EPA Method 17 of in-stack filtration. Other means of source sampling have been used, but they have been largely supplanted by EPA methods. Continuous in-stack monitors of opacity utilize attenuation of radiation across the effluent. Opacity measurements are affected by the particle size, shape, size distribution, refractive index, and the wavelength of the radiation (25,26). [Pg.384]

A second factor determining module selection is resistance to fouling. Membrane fouling is a particularly important problem in Hquid separations such as reverse osmosis and ultrafiltration. In gas separation appHcations, fouling is more easily controlled. Hollow-fine fibers are notoriously prone to fouling and can only be used in reverse osmosis appHcations if extensive, costiy feed-solution pretreatment is used to remove ah. particulates. These fibers caimot be used in ultrafiltration appHcations at ah. [Pg.74]

E. A. Wolfe, Gas Flow Rate and Particulate Matter Determination of Gaseous Effluents, Bay Area Air Pollution Control District 1480, San Erancisco, Calif., 1961. [Pg.307]

U. S. EPA Regulations on Standards ofPeformanceforNeir Stationay Sources, 40 CER 60, Appendix A, Reference Methods, Washington, D.C., 1993. ASTM D3685-92, Standard Test Methodfor Sampling and Determination of Particulate Matter in Stack Gases, American Society for Testing Materials, Philadelphia, Pa., 1992. [Pg.307]

Crystallite Size. From the width of the peaks the computer can determine the size of the crystaUites in the sample. The smaller the crystaUite size, the broader are the diffraction peaks. This kind of analysis is important for determining particulate size of certain materials (eg, sUica) where a range of crystaUite size may be a health hazard if inhaled into the lungs. [Pg.380]

Examination of equation 5 shows that if there are no chemical reactions, (R = 0), or if R is linear in and uncoupled, then a set of linear, uncoupled differential equations are formed for determining poUutant concentrations. This is the basis of transport models which may be transport only or transport with linear chemistry. Transport models are suitable for studying the effects of sources of CO and primary particulates on air quaUty, but not for studying reactive pollutants such as O, NO2, HNO, and secondary organic species. [Pg.380]

Aerosol Dynamics. Inclusion of a description of aerosol dynamics within air quaUty models is of primary importance because of the health effects associated with fine particles in the atmosphere, visibiUty deterioration, and the acid deposition problem. Aerosol dynamics differ markedly from gaseous pollutant dynamics in that particles come in a continuous distribution of sizes and can coagulate, evaporate, grow in size by condensation, be formed by nucleation, or be deposited by sedimentation. Furthermore, the species mass concentration alone does not fliUy characterize the aerosol. The particle size distribution, which changes as a function of time, and size-dependent composition determine the fate of particulate air pollutants and their... [Pg.382]


See other pages where Particulates, determination is mentioned: [Pg.142]    [Pg.38]    [Pg.315]    [Pg.426]    [Pg.107]    [Pg.397]    [Pg.142]    [Pg.38]    [Pg.315]    [Pg.426]    [Pg.107]    [Pg.397]    [Pg.8]    [Pg.185]    [Pg.198]    [Pg.215]    [Pg.265]    [Pg.270]    [Pg.586]    [Pg.776]    [Pg.140]    [Pg.373]    [Pg.384]    [Pg.384]    [Pg.384]    [Pg.73]    [Pg.150]    [Pg.544]    [Pg.554]    [Pg.299]    [Pg.319]    [Pg.248]   


SEARCH



Determination of particulate organic carbon

Determination of particulate organic carbon and nitrogen

Determination of particulate organic nitrogen

Gravimetric Determination of Smoke Particulates

Particulate matter determination

Particulate organic carbon, determination

Particulate organic nitrogen, determination

Particulates, determination organic content