Particulate matter conditions

Figure 2. Capillary-column gas chromatogram of the total polynuclear hydrocarbon fraction of air-particulate matter ). Conditions 11 m X 0.26 mm -i.d. glass capillary coated with SE-52 methylphenylsilicone stationary phase see Table 1 for... Figure 2. Capillary-column gas chromatogram of the total polynuclear hydrocarbon fraction of air-particulate matter ). Conditions 11 m X 0.26 mm -i.d. glass capillary coated with SE-52 methylphenylsilicone stationary phase see Table 1 for...
In operation, a spark source is normally first flushed with argon to remove loose particulate matter from any previous analysis. The argon flow is then reduced, and the cathode is preheated or conditioned with a short bum time (about 20 sec). The argon flow is then reduced once more, and the source is ran for sufficient time to build a signal from the sample. The spark is then stopped, and the process is repeated as many times as necessary to obtain a consistent series of analyses. The arc source operates continuously, and sample signal can be taken over long periods of time. [Pg.114]

The instrumental analyzer procedure, EPA Method 3A, is commonly used for the determination of oxygen and carbon dioxide concentrations in emissions from stationary sources. An integrated continuous gas sample is extracted from the test location and a portion of the sample is conveyed to one or more instrumental analyzers for determination of O9 and CO9 gas concentrations (see Fig. 25-30). The sample gas is conditioned prior to introduction to the gas analyzer by removing particulate matter and moisture. Sampling is conducted at a constant rate for the entire test run. Performance specifications and test procedures are provided in the method to ensure reliable data. [Pg.2199]

The concentration of indoor pollutants is a function of removal processes such as dilution, filtration, and destruction. Dilution is a function of the air exchange rate and the ambient air quality. Gases and particulate matter may also be removed from indoor air by deposition on surfaces. Filtration systems are part of many ventilahon systems. As air is circulated by the air-conditioning system it passes through a filter which can remove some of the particulate matter. The removal efficiency depends on particle size. In addition, some reactive gases like NOj and SOj are readily adsorbed on interior surfaces of a building or home. [Pg.385]

Sand conditioning. Particulate matter Medium-energy wet scrubbers. [Pg.508]

Particulate matter, in accordance with U.S. legislation, includes all substances (with the exception of unbound water) that under controlled conditions are present as solids (ash, carbon) or liquids in exhaust gases. [Pg.334]

The first method used for wear particle analysis is routine monitoring and trending of the solids content of machine lubricant. In simple terms the quantity, composition and size of particulate matter in the lubricating oil is indicative of the mechanical condition of the machine. A normal machine will contain low levels of solids with a size less than 10 microns. As the machine s condition degrades, the number and size of particulate matter will increase. [Pg.801]

When an ophthalmic ointment is manufactured, all raw material components must be rendered sterile before compounding unless the ointment contains an aqueous fraction that can be sterilized by heat, filtration, or ionizing radiation. The ointment base is sterilized by heat and appropriately filtered while molten to remove extraneous foreign particulate matter. It is then placed into a sterile steam-jacketed kettle to maintain the ointment in a molten state under aseptic conditions, and the previously sterilized active ingredients) and excipients are added aseptically. While still molten, the entire ointment may be passed through a previously sterilized colloid mill for adequate dispersion of the insoluble components. [Pg.452]

Emissions from hazardous waste combustors are regulated under two statutory authorities RCRA and the CAA. The MACT standards set emission limitations for dioxins, furans, metals, particulate matter, total chlorine, hydrocarbons/carbon monoxide, and destruction and removal efficiency (DRE) for organics. Once a facility has demonstrated compliance with the MACT standards by conducting its comprehensive performance test (CPT) and submitting its notification of compliance (NOC), it is no longer subject to the RCRA emission requirements with a few exceptions. RCRA-permitted facilities, however, must continue to comply with their permitted emissions requirements until they obtain modifications to remove any duplicative emissions conditions from their RCRA... [Pg.460]

The goal of setting operating requirements for hazardous waste combustion units is to ensure that the unit will operate in a way that meets the performance standards for organics, chlorine, particulate matter, and metal pollutants. The unit s permit will specify the operating conditions that have been shown to meet the performance standards for organics, chlorine gas, particulate matter, and metals. [Pg.462]


See other pages where Particulate matter conditions is mentioned: [Pg.525]    [Pg.41]    [Pg.379]    [Pg.371]    [Pg.287]    [Pg.292]    [Pg.2201]    [Pg.221]    [Pg.278]    [Pg.375]    [Pg.513]    [Pg.3]    [Pg.19]    [Pg.26]    [Pg.410]    [Pg.341]    [Pg.344]    [Pg.374]    [Pg.513]    [Pg.563]    [Pg.361]    [Pg.96]    [Pg.250]    [Pg.409]    [Pg.224]    [Pg.251]    [Pg.1159]    [Pg.234]    [Pg.147]    [Pg.406]    [Pg.144]    [Pg.462]    [Pg.896]    [Pg.117]    [Pg.200]    [Pg.287]    [Pg.132]    [Pg.42]    [Pg.222]    [Pg.714]   
See also in sourсe #XX -- [ Pg.354 ]