Exposed Hot Liquid Surfaces. Other partial-load heating losses may occur by radiation and convection from exposed liquid surfaces, as salt and lead baths (chap. 4), or from water baths (table 4.23 of reference 51). [Pg.187]


Results presented were determined at a partial load of the device (1-2 kW for the LHV of the hydrogen produced). At a burner off-gas (heating gas) inlet temperature of 350 °C, a S/C ratio of 1.5 and a pressure of 3 bar, full conversion of the methanol was achieved and 0.9 m3 h 1 hydrogen were produced. The hydrogen production rate was regarded as competitive with literature data. [Pg.369]

Heat pump operating costs can also be minimized by operating the chillers when the cost is least expensive, namely, at night when both the ambient temperature and the cost of electricity are low. Optimization can also be served by meeting partial loads by operating the chillers part of the time at maximum efficiency. Both of these strategies require storage, so that when the chillers are off, the chilled water or brine will continue to be available. As illustrated... [Pg.160]

Movement of fats and oils may be as the crude, partially refined, or finished oils and may be by rail tank cars, tank trucks, barges, and tanker ships. Rail tank cars are usually of the standard 60,566-L (16,000-gal 120,000-lb) or the jumbo 232,170-L (61,333-gal 460,000-lb) size. Standard cars are designed with a thermal expansion area of about 2% of the total capacity as a dome in the car. However, the rated capacity of the jumbo cars does not include any expansion space. Rather, these cars are equipped with a permanently installed bar marker located in the passageway, above which the quantity of oil should not be loaded. Heating coils can be installed for handling higher melting fats. [Pg.2629]

Figure S. Cross-section of the partially flooded heat loaded tube. Figure S. Cross-section of the partially flooded heat loaded tube.
The boiler is a product able to supply hot water in a central heating application. The appliance may be developed to provide the sanitary hot water. The performance parameters of the boiler are the nominal heating capacity in kW defined as full load mode and the nominal partial load capacity at 30% of nominal heating capacity. Tests are performed at standard conditions, which means supply plant temperatures outlet 80°C inlet 60°C and for condensing boilers, supply plant temperatures outlet 50°C and inlet 30°C. [Pg.718]

Whenever the occurence of amines has to be expected - for instance due to the presence of nitrous oxides or ammonia in the synthesis gas - a cation exchanger is normally provided in the predegassed raw methanol. Raw methanol is fed to the bottom half - usually between trays 8 and 10 counting from the top - of the prerun column which is equipped with a total of some 40 trays. Valve trays are normally used as they are characterized by a much better partial load behaviour than the cheaper sieve trays. The column is heated by a reboiler... [Pg.138]

Low current densities - Low partial load toleration - System dimensions and complexity (footprint) - Extensive gas purification - Corrosive liquid electrolyte - Corrosive environment ( acidic membrane) - High investment costs due to costly components (catalysts, current collectors, separator plates) - Laboratory and test phase - Long-term stability (mechanical) - Heat management... [Pg.200]

Where the test supphes data for an analytical evaluation of the package, measurements made during the test should be corrected for non-standard initial conditions of ambient temperature, insolation, internal heat load, pressure, etc. The effects of partial loading, i.e. less than full contents, on the package heat capacity and heat transfer should be assessed. [Pg.182]

Since the Ca-Br water splitting chemical reaction requires a heat source at 725 C to cause the CaBr2 + H2O CaO + 2HBr reaction to take place, that temperature must be maintained even if the water cracking plant is operating at only partial load. Therefore, for STAR-H2, another design constraint was imposed - the core outlet temperature of 800X at full load must also be maintained at all levels of partial load. [Pg.676]

Heat losses affect the fuel processor efficiency, especially at partial system load. This becomes obvious when taking into consideration that the reactors of the fuel processor require an elevated operating temperature. This temperature will not decrease at partial load. Therefore heat losses remain constant and become dominant at partial load of the system. Smaller system size has similar effects. [Pg.9]

It can be concluded that a stack concept with pure passive cooling is not advisable because the stack temperature varies strongly with the stack power and as a result the specified temperature range may be exceeded. Dependent on the stack power (full load, partial load) during normal operation additional cooling or heating is required. Therefore an active thermal management system is mandatory. [Pg.449]

At partial loads on aU units, regardless of the fuel fired, it is necessary to increase the excess air as the load is reduced. Burner dampers are designed not to close tightly in order to permit the air to protect the idle bumer(s) from overheating by radiant heat from nearby operating burners. [Pg.928]

There are two types of supercritical FPPs. One is the constant pressure FPP that starts heating and operates at partial load at the supercritical pressure. The other is the sliding pressure FPP that starts heating at a subcritical pressure, and operates at subcritical pressure at partial load. A steam-water separator and a drain tank are needed for the startup of the sliding pressure FPP. The sliding pressure FPP operates with better thermal efficiency at subcritical pressure at partial load than the constant pressure FPP. In Japan, nuclear power plants are used for base load, and the FPPs are used for daily load following. Minimum partial load is 30% for the constant pressure FPP and 25% for the sliding pressure one [41,42]. [Pg.22]


See other pages where Partial-Load Heating is mentioned: [Pg.187]    [Pg.187]    [Pg.27]    [Pg.625]    [Pg.105]    [Pg.306]    [Pg.330]    [Pg.307]    [Pg.209]    [Pg.65]    [Pg.200]    [Pg.216]    [Pg.343]    [Pg.349]    [Pg.355]    [Pg.203]    [Pg.339]    [Pg.147]    [Pg.676]    [Pg.707]    [Pg.212]    [Pg.249]    [Pg.77]    [Pg.198]    [Pg.46]    [Pg.105]    [Pg.335]    [Pg.99]    [Pg.399]    [Pg.283]    [Pg.283]    [Pg.460]    [Pg.157]    [Pg.346]   