Packing comparisons

Figure 9-28. Packing comparison at design point for IntaJox ceramic saddles, metal pall rings, and metal IntaJox . Reproduced by permission of American Institute of Chemical Engineers, Strigle, R. F., Jr. and Rukovena, F., Chemical Engineering Progress, Mar. (1979) p. 86 all rights reserved. Figure 9-28. Packing comparison at design point for IntaJox ceramic saddles, metal pall rings, and metal IntaJox . Reproduced by permission of American Institute of Chemical Engineers, Strigle, R. F., Jr. and Rukovena, F., Chemical Engineering Progress, Mar. (1979) p. 86 all rights reserved.
Ithough knowledge-based potentials are most popular, it is also possible to use other types potential function. Some of these are more firmly rooted in the fundamental physics of iteratomic interactions whereas others do not necessarily have any physical interpretation all but are able to discriminate the correct fold from decoy structures. These decoy ructures are generated so as to satisfy the basic principles of protein structure such as a ose-packed, hydrophobic core [Park and Levitt 1996]. The fold library is also clearly nportant in threading. For practical purposes the library should obviously not be too irge, but it should be as representative of the different protein folds as possible. To erive a fold database one would typically first use a relatively fast sequence comparison lethod in conjunction with cluster analysis to identify families of homologues, which are ssumed to have the same fold. A sequence identity threshold of about 30% is commonly... [Pg.562]

Pulsed Columns. The efficiency of sieve-plate or packed columns is increased by the appHcation of sinusoidal pulsation to the contents of the column. The weU-distributed turbulence promotes dispersion and mass transfer while tending to reduce axial dispersion in comparison with the unpulsed column. This leads to a substantial reduction in HETS or HTU values. [Pg.75]

Inorganic membranes (29,36) are generaUy more stable than their polymeric counterparts. Mechanical property data have not been definitive for good comparisons. IndustriaUy, tube bundle and honeycomb constmctions predominate with surface areas 20 to 200 m. Cross-flow is generaUy the preferred mode of operation. Packing densities are greater than 1000 /m. Porous ceramics, sintered metal, and metal oxides on porous carbon support... [Pg.154]

LB films of 1,4,8,11,15,18-hexaoctyl-22,25-bis-(carboxypropyl)-phthalocyanine (2), an asymmetrically substituted phthalocyanine, were stable monolayers formed at the water—air interface that could be transferred onto hydrophilic siUca substrates (32—34). When a monolayer film of the phthalocyanine derivative was heated, there was a remarkable change in the optical spectmm. This, by comparison to the spectmm of the bulk material, indicated a phase transition from the low temperature herringbone packing, to a high temperature hexagonal packing. [Pg.533]

Comparisons by von Stockar and Wilke [Ind. Eng. Chem. Fundam., 16, 89 (1977)] between the rigorous and the classical adiabatic design methods for packed towers indicate that the simple adiabatic method underestimates the packing depths by as much as a factor of 1.25 to 1.5. Thus, when using the (dassical adiabatic method, one should consider the possible need to apply a design safety factor. [Pg.1360]

A comparison of the axial-dispersion coefficients obtained in oscil-lating-spiral and dense-bed crystalhzers is given in Table 22-5. The dense-bed column approaches axial-dispersion coefficients similar to those of densely packed ice-washing cohimns. [Pg.1994]

Generalizations are not as easy for structured packings as for random packings. See the following subsection, Comparison to Trays, for study type structured packing data. [Pg.88]

Kister points out that, in the final analysis, design comparisons of packing versus trays must be evaluated... [Pg.88]

Equations (2) and (4) allow the permissible extra-column dispersion to be calculated for a range of capillary and packed columns. To allow comparison, data was included for a GC column, in addition to LC columns. The results are shown in Table 1. [Pg.289]

Table 9.7 summarizes the comparison of SEC column performance with regard to particle size of the packing material. The author tried to create this table using the test results of different manufacturers of styrene-divinyl-benzene columns. [Pg.279]

Another advantage of HdC is its generosity in terms of mobile-phase selection. The polymer size and solution properties of a polymer can be studied using HdC, especially OTHdC, in almost any solvent. In SEC, by comparison, the packing material and mobile phase have to be selected to prevent the nonsize exclusion effect. Because the instrumentation of HdC is similar to SEC, and the packing material and columns have become available commercially, this technique will gain in popularity. [Pg.608]

Table 1.1 Comparison of packed columns for analytical chromatography... Table 1.1 Comparison of packed columns for analytical chromatography...
In the elucidation of retention mechanisms, an advantage of using enantiomers as templates is that nonspecific binding, which affects both enantiomers equally, cancels out. Therefore the separation factor (a) uniquely reflects the contribution to binding from the enantioselectively imprinted sites. As an additional comparison the retention on the imprinted phase is compared with the retention on a nonimprinted reference phase. The efficiency of the separations is routinely characterized by estimating a number of theoretical plates (N), a resolution factor (R ) and a peak asymmetry factor (A ) [19]. These quantities are affected by the quality of the packing and mass transfer limitations, as well as of the amount and distribution of the binding sites. [Pg.154]

Packed column SFC has also been applied to preparative-scale separations [42], In comparison to preparative LC, SFC offers reduced solvent consumption and easier product recovery [43]. Whatley [44] described the preparative-scale resolution of potassium channel blockers. Increased resolution in SFC improved peak symmetry and allowed higher sample throughput when compared to LC. The enhanced resolution obtained in SFC also increases the enantiomeric purity of the fractions collected. Currently, the major obstacle to widespread use of preparative SFC has been the cost and complexity of the instrumentation. [Pg.306]


See other pages where Packing comparisons is mentioned: [Pg.517]    [Pg.517]    [Pg.517]    [Pg.517]    [Pg.135]    [Pg.299]    [Pg.2367]    [Pg.95]    [Pg.39]    [Pg.150]    [Pg.254]    [Pg.426]    [Pg.491]    [Pg.347]    [Pg.606]    [Pg.1321]    [Pg.1360]    [Pg.1477]    [Pg.2181]    [Pg.447]    [Pg.445]    [Pg.92]    [Pg.333]    [Pg.264]    [Pg.14]    [Pg.129]    [Pg.246]    [Pg.360]    [Pg.431]    [Pg.447]    [Pg.32]    [Pg.377]    [Pg.609]   
See also in sourсe #XX -- [ Pg.656 ]




SEARCH



Comparison Between Packed Bed and Coating in Micro Tubes Applied to Methanol Steam Reforming

Comparison of Packed and Fluidized Beds

Comparison of Packed and Tray Columns

Comparison of Random Packings from Different Generations

Packed towers performance comparison, example

Packings comparison with other highly