Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Other Modules

Hollow fibers or capillary modules have not yet found an industrial application in pervaporation or vapor-permeation processes. A few data have been reported where organic capillary structures with an outside diameter of 0.5 to 1 mm have been coated with silicon and used in organophilic separation. With the flow on the shell side permeate pressure losses inside the bore of the fiber control the process. For specific organophilic applications, these pressure losses may be tolerable. For hydrophilic processes, however, the useful length of a module would be of the order of 20 to 30 cm only, even at an inner diameter of the capillary of 1 mm. Such a module, including housing and connection in any industrial application, is more costly than a plate module. So far no potting material is available that combines the necessary chemical and mechanical stability at the operation temperature and pressure of a dehydration plant. [Pg.187]

Microfibers with an inner diameter of 20 pm and a wall thickness of 10 to 20 pm have been proposed, too. The specific flux through such a homogeneous membrane would be low, but outbalanced by high packing density and low membrane costs. The fiber length would be of the order of 20 cm, arranged in a modified module, in which the fibers would be potted in the axial direction into the wall of a tube. So far no reports are known on any application of such a module. [Pg.187]


First, the reconcihation can be done separately around each module. Each module is studied alone. The measurements are reconciled to the individual module constraints without consideration of any other module with common streams. For example, the first module in the figure is reconciled, and the measurements corresponding to... [Pg.2569]

Command modules communicate with other modules through a local area network (LAN). Through this LAN, command modules receive information from the local control modules and store data. These data can be stored from a week to two years, depending on the recording interval and the number of points to be monitored. Unlike host-based systems, which use a central computer to interrogate each command module individually, the computer interface can tap into the network like any other command module. [Pg.466]

Characterisation Typical data that may be provided to describe the physical and chemical characteristics of the drug substance are shown in Figure 6.3. The description of the drug product should include the recipe detailing all the other ingredients (excipients) that are used to formulate the final product. It is vital to provide adequate data on the dissolution behaviour of the drug product, as the reviewer may wish to tie this in with pharmacokinetic or bioavailability data submitted in the other modules. [Pg.103]

In addition to supplementation or dietary intake of the xanthophylls, several other modulators that influence the MPOD response of subjects to supplementation with xanthophylls were reported (Mares et al. 2006). Larger waist circumference and the presence of diabetes predicted a decrease of MPOD. In contrast to earlier findings, iris color was not related to MPOD. No dependence of MPOD on age was revealed in this study but this may be because of its lower age limit of 53 years. [Pg.266]

The continuous sinusoidal composition change that occurs during spinodal decomposition can be considered to be a modulation of the solid structure. It is now known that many structures employ modulation in response to compositional or crystallographic variations, and in such cases the material flexibly accommodates changes without recourse to defect populations. (Other modulations, in, for example, magnetic moments or electron spins, although important, will not be discussed here.)... [Pg.192]

The real structures of these phases are more complex. The coordination of the Ti atoms is always six, but the coordination polyhedron of sulfur atoms around the metal atoms is in turn modulated by the modulations of the Sr chains. The result of this is that some of the TiS, polyhedra vary between octahedra and a form some way between an octahedron and a trigonal prism. The vast majority of compositions give incommensurately modulated structures with enormous unit cells. As in the case of the other modulated phases, and the many more not mentioned, composition variation is accommodated without recourse to defects. ... [Pg.197]

Fig. 8.5 Interaction between the expert system and the other modules of the intelligent system. [Pg.124]

A modular electrolyser contains a number of discreet modules consisting of anode, membrane and cathode. These sealed modules can be individually removed from the electrolyser without the other modules being affected. The key to this type of design is to ensure a good electrical contact between adjacent modules. [Pg.242]

The main elements of the used input output model ISIS are described in the following. At the core of ISIS is a statistical input output model (IO model) used to examine the structural impacts of the various strategies. Other modules for employment effects, qualification structure and job conditions, regional effects and environmental effects were developed or added to analyse other dimensions of sustainability. The results of the scenario calculations from the IO model, i.e., production changes as a result of the different strategies, serve as inputs for the other modules. [Pg.537]

The calibration order is detector => pump => autosampler (as the detector is often used to calibrate other modules). [Pg.293]

The expert system is comprised of a series of modules encompassing the many varied aspects of decision-making. Information from each of these modules is available to other modules to make decisions where they require interrelated knowledge. [Pg.34]

For example, the first module. Confidence Level, is key to many of the decisions that will be made in other modules. The first query by the computer asks the user whether the resulting analytical data will be used for enforcement or litigation actions. If the answer is yes, then a high level of confidence will be needed and the user is advised of this assignment. If the answer is no, then the user is asked to specify how important he/she views the accuracy and precision of the data. [Pg.34]

Many problems that arise in the application of adsorption chromatography can be related to the slow attainment of equilibrium distribution of the omnipresent water and other modulators tetween eluent and stationary phase. With suitable precautions, such as moisture control, reproducible work is possible with both silica and alumina as the stationary phase. [Pg.56]


See other pages where Other Modules is mentioned: [Pg.97]    [Pg.538]    [Pg.2027]    [Pg.2043]    [Pg.336]    [Pg.280]    [Pg.705]    [Pg.191]    [Pg.24]    [Pg.18]    [Pg.331]    [Pg.184]    [Pg.358]    [Pg.297]    [Pg.715]    [Pg.867]    [Pg.27]    [Pg.41]    [Pg.541]    [Pg.123]    [Pg.80]    [Pg.95]    [Pg.292]    [Pg.67]    [Pg.258]    [Pg.268]    [Pg.193]    [Pg.203]    [Pg.212]    [Pg.110]    [Pg.215]    [Pg.292]    [Pg.58]    [Pg.166]    [Pg.708]    [Pg.762]    [Pg.12]   


SEARCH



Other Modulation Techniques

Other Modulator Efforts PR, MR, AR, PPAR, FXR and LXR

Other Module Configurations

Other Sample Modulation Measurements with Step-Scan Interferometers

Other Types of Modulated Structures

Physiological modulators effectors, other

© 2024 chempedia.info