Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Interval recording

Obviously do not risk safety while driving in order to make your record if you cannot adhere to the 15-minute intervals record a note of your feelings during the drive afterwards. [Pg.172]

Time interval recorded Tannic acid at 7 °C (% of scale) Tannic acid at 18 °C (% of scale) Catechin at 7°C (% of scale) Catechin at 18 °C (% of scale)... [Pg.278]

PR interval, QRS interval, R amplitude, and QT/QTc interval recorded every 15 to 30 minutes for the first 4 hours and hourly thereafter for 8 hours Times may vary based on toxicokinetic parameters... [Pg.887]

A calibration programme should be available and should provide information such as calibration standards and limits, responsible persons, calibration intervals, records and actions to be taken when problems are identified. [Pg.114]

Determination of the temperature interval at which each contributory reaction occurs TG can provide a rapid and effective method of qualitatively establishing a pattern of reactivity and determining whether an overall change proceeds as a single process or through a sequence of consecutive steps. Mass losses at each step, as a fraction of the total, can be used as a qualitative indication of reaction stoichiometries and the temperature interval recorded. Such preliminary conclusions should be regarded as requiring analytical or structural confirmation, EGA, or x-ray diffraction. [Pg.156]

Figure 4.22 Ventricular activation time by age in lead V1, each curve corresponding to the indicated percentile level ( = mean). The ventricular activation time interval recorded in lead VI increases after birth up to age 3-7 days, then decreases during infancy, reaching a plateau level by age 1-3 years, until adolescence. Figure 4.22 Ventricular activation time by age in lead V1, each curve corresponding to the indicated percentile level ( = mean). The ventricular activation time interval recorded in lead VI increases after birth up to age 3-7 days, then decreases during infancy, reaching a plateau level by age 1-3 years, until adolescence.
Products that have not gelled or solidified and are covered by points test interval, record, viscosity and viscosity sensitivity may be used by a customer for a further period of 6 months. Other pre-defined periods may be used for test intervals. [Pg.114]

The key factors in snccessful statistical process control are selection of an appropriate control standard, selecting an appropriate monitoring interval, recording and analyzing the control standard resnlts, and recording appropriate information in the instrument log. A control standard shonld be selected on the basis of its ability to accurately monitor the performance of the instmment. It shonld be sensitive to instrument performance, be available in large qnantities, and be... [Pg.983]

At work, interval recording is often the most practical approach to observing and recording critical behaviors. A checklist of critical behaviors is used and the observer merely watches an individual work for a set period of time and checks off "safe" or "at-risk" for each behavior on the list. The number of "safe" and "at-risk" checkmarks can be totaled and used to calculate the percentage of "safe" behaviors recorded in a particular interval. This is the approach recommended by Krause et al. (1996) and McSween (1995). [Pg.141]

Figure 5 provides an example of AE monitoring data from 22.01.1997 to 03,03.1997, in terms of time history of the main plant parameters (fig.Sa), as well as of the AE RMS values (fig. 5b). Normally, very little or no events were recorded, with the exception of the above period, in which an AE activity, very much concentrated in time and space, could be observed a sharp step in cumulative AE events takes place in a short, well defined time interval. A smaller sharp step in EA events had been observed a few days earlier, in the same position. [Pg.78]

Figure C 1.5.7. Surface-eiilianced Raman spectra of a single rhodamine 6G particle on silver recorded at 1 s intervals. Over 300 spectra were recorded from this particle before tlie signals disappeared. The nine spectra displayed here were chosen to highlight several as yet unexplained sudden changes in botli frequency and intensity. Reprinted witli pennission from Nie and Emory [ ]. Copyright 1997 American Association for tlie Advancement of Science. Figure C 1.5.7. Surface-eiilianced Raman spectra of a single rhodamine 6G particle on silver recorded at 1 s intervals. Over 300 spectra were recorded from this particle before tlie signals disappeared. The nine spectra displayed here were chosen to highlight several as yet unexplained sudden changes in botli frequency and intensity. Reprinted witli pennission from Nie and Emory [ ]. Copyright 1997 American Association for tlie Advancement of Science.
Control of Dyeing Equipment. Over the years, the dyer and machinery manufacturer have appHed any mechanical or electrical equipment that would enable them, day after day, to produce repeatable dyeings of top quaHty. First, thermometers were installed in dye lines these soon evolved into thermocouples with remote recording. Other improvements were soon developed, such as automatic four-way valves with variable-interval controls, flow controls, pressure recorders, hydrauHc and air pressure sets on roUers, pH controls, etc. [Pg.371]

The historical data is sampled at user-specified intervals. A typical process plant contains a large number of data points, but it is not feasible to store data for all points at all times. The user determines if a data point should be included in the list of archive points. Most systems provide archive-point menu displays. The operators are able to add or delete data points to the archive point hsts. The samphng periods are normally some multiples of their base scan frequencies. However, some systems allow historical data samphng of arbitraiy intei vals. This is necessaiy when intermediate virtual data points that do not have the scan frequency attribute are involved. The archive point lists are continuously scanned bv the historical database software. On-line databases are polled for data. The times of data retrieval are recorded with the data ootained. To consei ve storage space, different data compression techniques are employed by various manufacturers. [Pg.773]

Sticking of valve stems is common if solids are present in the steam. The steam mast be without sohds. (Note comments later under loss of power.) It is important that units operating on a steady load for long periods be checked for sticking stems at regular intervals. The records show that in several cases deposits have caused the stem of both the governor valve and the trip valve to stick when there was a loss of load. The effect of the loss of load was destructive overspeed. [Pg.2505]

Locate the RTDs at the likely hot spots, as at the joints of the busbars. Figure 14.2 illustrates the likely locations of the RTDs. The test may be carried out as noted earlier and temperature readings tabulated at 30-minute or l-hour intervals, whichever is more appropriate. The temperature rise, estimated with the highest temperature recorded by any of the RTDs, would refer to the ambient... [Pg.427]


See other pages where Interval recording is mentioned: [Pg.38]    [Pg.362]    [Pg.106]    [Pg.157]    [Pg.632]    [Pg.91]    [Pg.3597]    [Pg.197]    [Pg.793]    [Pg.175]    [Pg.44]    [Pg.141]    [Pg.240]    [Pg.38]    [Pg.362]    [Pg.106]    [Pg.157]    [Pg.632]    [Pg.91]    [Pg.3597]    [Pg.197]    [Pg.793]    [Pg.175]    [Pg.44]    [Pg.141]    [Pg.240]    [Pg.222]    [Pg.38]    [Pg.541]    [Pg.882]    [Pg.207]    [Pg.445]    [Pg.265]    [Pg.2]    [Pg.466]    [Pg.508]    [Pg.512]    [Pg.17]    [Pg.422]    [Pg.375]    [Pg.112]    [Pg.378]    [Pg.708]    [Pg.1324]    [Pg.43]    [Pg.312]    [Pg.345]   
See also in sourсe #XX -- [ Pg.141 ]




SEARCH



Timed interval recording, detection method

© 2024 chempedia.info