Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Origin-specific analysis

We argue in this chapter that an implementation analysis should inform the entire life cycle of a standard, from the original specification, through derivation, to its implementation, use, review, and eventual revision or withdrawal. It will also be helpful to anticipate future uses such as the use of compliance assessments to compare regions and nations (where these are not in place already). [Pg.45]

There is increasing evidence that pesticides have contaminated extensive areas of the world not directly treated with pesticides. In many instances, the translocation can be attributed to food or water as the transmission vehicle. Another medium of dispersal of pesticides is the atmosphere. Analyses of rainwater and dust have revealed the presence of chloro-organic substances in all samples examined. Identification of specific pesticides has demonstrated that at least some of the chloro-organic compounds are pesticidal in origin. An analysis of dust, whose distant origin was documented by meteorological evidence, proved that pesticide-laden dust can be transported over great distances via the atmosphere and can be deposited over land surfaces remote from the point of application. [Pg.171]

Pearson, A., McNichol, A. P., Benitez-Nelson, C., Hayes, J. M., andEghnton, T. I. (2001). Origins of lipid biomarkers in Santa Monica Basin surface sediment A case study using compoimd-specific analysis. Geochim. Cosmochim. Acta 65, 3123—3137. [Pg.767]

Enantio-IRMS also offers a direct method to detect conclusively a blend of enantio-pure chiral flavour compounds with synthetic racemates. An origin-specific enantiomeric ratio may be imitated but not yet detectable, neither by enantioselective analysis nor by IRMS-measurements. However, in the case of enantio-IRMS a simulated origin-specific enantiomeric distribution is proved by different 5 C-levels of the detected enantiomers. [Pg.693]

A congener-specific analysis of a commercial PCB preparation and the PCB composition of a human milk sample were reported originally by Safe et al. (1985b). Recent studies have demonstrated the analysis of non-ortho coplanar and mono-ortho coplanar PCBs in breast milk (Dewailly et al. 1991) and coplanar PCBs in serum and adipose tissue (Patterson et al. 1994). Determination of these congeners (PCBs 77, 126, 169) is useful in assessing the toxic potential of breast milk for infants. [Pg.673]

That is, if water sorption occurs on two types of sites, a polymer site and a pol3rmer-water site, the influence of the former will predominate as P and the amount of sorbed water simultaneously approach zero. A plot of vs P with a slope of k] (the inverse of Equation 2), as shown in Figure 1, is tangent to the experimental Isotherm at the origin. The analysis outlined allows a unique specification of x interaction parameter, through use of the limiting (Henry s Law) approximation of the Flory-Hugglns theory ( 3). That is... [Pg.443]

Before any planned changes are made, including organizational and safety control structure changes, their impact on safety must be evaluated. Whether this process is expensive depends on how the original hazard analysis was performed and particularly how it was documented. Part of the rationale behind the design of intent specifications was to make it possible to retrieve the information needed. [Pg.397]

The test certificates for such analysis should mention the reference of order (name of client, order number, a copy of original specifications), production batch number, date of manufacture, and manufacturer s code—for ease of identification of the reaction units, process plants, operation sequence, or conditions maintained during production on the date of manufacture in future. These will be useful if any communication (complaint or compliment) is received about the product. [Pg.28]

From a general point of view, ion pair LC systems can be expected to give a performance and durability comparable to other bonded-phase systems. However, a small proportion of the ion pair reagent may become irreversibly bound to the stationary phase, possibly to free silanol groups, and if so the column cannot be regenerated to its original condition. In practice, this means that once a column has been used for an ion pair separation it should be retained for the specific analysis in question. Attempts to reuse the column for conventional reversed-phase chromatography may lead to unexpected and spurious results. [Pg.2585]

Interconnections consist of multiplexers and nets. Initially, nets are used to interconnect functional units and registers as indicated in the original specification (the data-flow graph). Multiplexers are used for nets with more than one source. Path analysis and lifetime information are also used to generate the correct interconnection. [Pg.93]

The mineral salts were reagent grade (Merck pro analysis). Their aqueous solutions were purified by foaming in a stream of N2 before use. Radioactive " CaCl2 was supplied by Amersham (England). Its original specific activity was of the order of 100-200 mCi g It has been diluted isotopically to a specific activity equal to 3-4 mCi g" ... [Pg.208]

Complex environmental samples originate from diverse matrices (the predominant material of which the sample to be analyzed is composed). These matrices, usually either water or soil/sediment, can contain as many as 50 to 100 organic components at widely varying concentrations. The EPA approach to the analysis of these samples involves the analysis of specific (or target) compounds and the use of authentic standards for quality control. The current number of standards in the EPA repository is about 1500, and their analysis is covered by various approved methods. [Pg.295]

Development of useful shortcut methods by intuitive and evolutionary mental analysis alone must surely be extremely fulfilling. We will see later how other devel-opmentally oriented individuals are able to build upon the original shortcut method ideas to create variations on the theme for specific applications. [Pg.400]

The following analysis enables one to calculate the diameter of a pipeline transporting any compressible fluid. The required inputs are volumetric flow rate, the specific gravity of the gas relative to air, flow conditions, compressibility factor Z where Z is defined by nZRT = PV, the pressure at the point of origin and the destination, the pipe length, and pipe constants such as effective roughness. The working equations have been obtained from the literature. Since the friction factor... [Pg.514]


See other pages where Origin-specific analysis is mentioned: [Pg.379]    [Pg.380]    [Pg.693]    [Pg.379]    [Pg.380]    [Pg.693]    [Pg.279]    [Pg.102]    [Pg.157]    [Pg.266]    [Pg.21]    [Pg.498]    [Pg.517]    [Pg.57]    [Pg.188]    [Pg.152]    [Pg.31]    [Pg.252]    [Pg.397]    [Pg.347]    [Pg.443]    [Pg.1532]    [Pg.105]    [Pg.135]    [Pg.930]    [Pg.46]    [Pg.108]    [Pg.92]    [Pg.13]    [Pg.178]    [Pg.1791]    [Pg.241]    [Pg.298]    [Pg.338]    [Pg.115]    [Pg.327]    [Pg.2]   
See also in sourсe #XX -- [ Pg.379 ]




SEARCH



Specific Analysis

© 2024 chempedia.info