The Inductively Coupled Plasma (ICP) has become the most popular source for multielement analysis via optical spectroscopy since the introduction of the first commercial instruments in 1974. About 6000 ICP-Optical Emission Spectrometry (ICP-OES) instruments are in operation throughout the world. [Pg.633]

The basic instrumentation used for spectrometric measurements has already been described in the previous chapter (p. 277). Methods of excitation, monochromators and detectors used in atomic emission and absorption techniques are included in Table 8.1. Sources of radiation physically separated from the sample are required for atomic absorption, atomic fluorescence and X-ray fluorescence spectrometry (cf. molecular absorption spectrometry), whereas in flame photometry, arc/spark and plasma emission techniques, the sample is excited directly by thermal means. Diffraction gratings or prism monochromators are used for dispersion in all the techniques including X-ray fluorescence where a single crystal of appropriate lattice dimensions acts as a grating. Atomic fluorescence spectra are sufficiently simple to allow the use of an interference filter in many instances. Photomultiplier detectors are used in every technique except X-ray fluorescence where proportional counting or scintillation devices are employed. Photographic recording of a complete spectrum facilitates qualitative analysis by optical emission spectrometry, but is now rarely used. [Pg.288]

Different analytical techniques such as ICP-OES (optical emission spectrometry with inductively coupled plasma source), XRF (X-ray fluorescence analysis), AAS (atomic absorption spectrometry) with graphite furnace and flame GF-AAS and FAAS, NAA (neutron activation analysis) and others, are employed for the trace analysis of environmental samples. The main features of selected atomic spectrometric techniques (ICP-MS, ICP-OES and AAS) are summarized in Table 9.20.1 The detection ranges and LODs of selected analytical techniques for trace analysis on environmental samples are summarized in Figure 9.15.1... [Pg.298]

Atomic emission spectrometry (AES) is also called optical emission spectrometry (OES). It is the oldest atomic spectrometric multielement method which originally involved the use of flame, electric arc or spark excitation. Recently there has been considerable innovation in new sources plasma sources and discharges under reduced pressure. Littlejohn et al. (1991) have reviewed recent advances in the field of atomic emission spectrometry, including fundamental processes and instrumentation. [Pg.253]

Furthermore, it is desired that atomization and excitation occur in an inert chemical environment to minimize possible interferences. Different flame, spark, and arc somces have been used as the excitation sources since the beginning of the twentieth century however, none of these approximates the fiiU fist of conditions fisted above. It was not until mid-1960s when the analytically useful plasma sources were developed, subsfantially improving fhe capabilities of OES. The first commercially available inductively coupled plasma optical emission spectrometry (ICP-OES) was introduced in 1974 and since then the revival of OES can be noted. [Pg.6083]

Millard D. L., Shan H. C. and Kirkbright G. F. (1980) Optical emission spectrometry with an inductively coupled radiofrequency argon plasma source and sample introduction with a graphite rod electrothermal vaporization device. [Pg.321]

Decker R. J. (1980) Some analytical characteristics of a three electrode DC argon plasma source for optical emission spectrometry, Spectroehim Acta, Part B 35 19—35. [Pg.330]

During the 1980s, a rapidly increasing number of methods have been published for mercury determination by AES (often called OES = optical emission spectrometry) after excitation/ionization in a gas plasma, usually argon. The plasma source most frequently used is an ICP, but also other kinds of plasma sources are used, e.g. alternating current plasma (ACP), direct current plasma (DCP), and microwave-induced plasma (MIP). AES has a wide multi-element capability the linear range extends over 4-6 orders of magnitude. [Pg.427]

Preferred methods in trace determination of the elements include atomic absorption spectrometry (AAS), optical emission spectrometry (OES) with any of a wide variety of excitation sources [e.g., sparks, arcs, high-frequency or microwave plasmas (inductively coupled plasma, ICP microwave induced plasma, MIP capacitively coupled micro-wave plasma, CMP), glow discharges (GD). hollow cathodes, or laser vaporization (laser ablation)], as well as mass spectrometry (again in combination with the various excitation sources listed), together with several types of X-ray fluorescence (XRF) analysis [51]. [Pg.17]

Radionuclides in methodological studies of determination methods are sometimes useful. These are the measurement processes associated with the determination stage of a combined analytical procedure. Sources of systematic error in atomic absorption spectroscopy, optical emission spectrometry, and electrochemical methods, as well as optimization of the determination procedures have been examined. [Pg.136]


See other pages where Optical emission spectrometry sources is mentioned: [Pg.221]    [Pg.615]    [Pg.125]    [Pg.162]    [Pg.28]    [Pg.199]    [Pg.8]    [Pg.44]    [Pg.125]    [Pg.282]    [Pg.28]    [Pg.199]    [Pg.6083]    [Pg.86]    [Pg.375]    [Pg.241]    [Pg.6082]    [Pg.274]    [Pg.695]    [Pg.1085]    [Pg.5181]    [Pg.99]    [Pg.897]    [Pg.86]    [Pg.375]    [Pg.9]    [Pg.145]    [Pg.26]    [Pg.671]    [Pg.3]   
See also in sourсe #XX -- [ Pg.13 , Pg.14 , Pg.15 ]