Operator spectral resolution

Nonresonance Raman spectra of the alternating LB films were measured by a total reflection method shown in Figure 23. The films were deposited on quartz prisms. The s-polarized beam of 647.1 nm from a Kr laser was incident upon the interface between the quartz and film at an angle of 45° from the quarz side, and totally reflected. Raman line scattered from the film in the direction of 45° from the surface was measured through a Spex Triplemate by a Photometries PM512 CCD detector with 512x512 pixels operated at -125 °C. The spectral resolution was about 5 cm 1. [Pg.180]

Finally, mention should be made of the new spectrophotometers based on an array of detectors (see Chapter 2). The operation of these spectrophotometers is much simpler, as they are not monochromators, each detector in the array being used to record a wavelength interval. However, these monochromators suffer from the drawback of poor spectral resolution. [Pg.15]

Diode resolution is an important consideration in a PDAD detector. It is calculated by dividing the wavelength range by the number of diodes in the array. This, in combination with the optical resolution, will affect the spectral resolution of the instrument (i.e., the wavelength in nm, between data points in an acquired spectrum). (Operation and Maintenance of the ZQ with MassLynx, Waters Corporation.)... [Pg.21]

Sensor Agency Satellite Operating Dates Resolution (m) Number of Bands Spectral Coverage (nm) Ref. [Pg.16]

All test solutions, except otherwise mentioned, were degassed by hree freeze-pump-thaw cycles with a vacuum line operated under 10 torr pressure. Problems of background fluorescence originating from sulfonates themselves could be adequately minimized by proper choice of probe/sulfonate ratios. The excitation wavelength was set at 340 nm. Emission spectra were obtained in constant energy mode. The spectral resolution was 3 nm. [Pg.91]

Because they can precisely measure wavelengths, FTIR spectrometers permit spectra and file storage using an instrument form at and certain rules so that spectra can be treated by instruments from other manufacturers. Each data point in the spectrum can be stored as an ACSII file. However, the software normalises the raw data and lowers the spectral resolution to obtain fewer calculated values (one point every 8 or 4 cm-1 - giving less than 1 Koctet/spectrum). The inverse operation can be used to give a proper corrected image of the spectrum. [Pg.181]

Commercial Fourier transform spectrometers operating at moderate resolution (1cm-1) require fractions of seconds to complete a scan of the interferometric mirror (scans may only take tens of milliseconds if only low spectral resolution is required). A new strategy must now be used to study the... [Pg.3]

We can now list some of the most important properties of the various types of operators and matrices Any hermitean, antihermitean, unitary, or idempotent operator has a spectral resolution where the eigenvectors form an ON-basis, so that... [Pg.8]

The linear operators on a vector space forms themselves a vector space, called operator space. In this context, the original vector space is called the carrier space for the operators. The operator space is sometimes normed, but usually not. Since operator products are defined, we have here a vector space where a product of vectors to give a vector is defined. Such a vector space is also called a linear algebra. Operations and functions can be defined in the operator space thus we can define superoperators for which the operator space is the carrier space. The hierarchy is not usually driven any further. Functions are usually named in analogy to their analytical counterparts. To be specific, assume that A has a spectral resolution... [Pg.9]

The resolvent R(z) is defined, for some particular operator A, as R(z) = (zi - A)-1. This analytic function of the parameter-dependent operator zi — A has the following property (assuming again the existence of a spectral resolution) ... [Pg.9]

Consider now a self-adjoint positive-definite operator A Its eigenvalues are all positive, and the positive square root can be defined in terms of the spectral resolution ... [Pg.77]

With regard to analysis, there could be a different set of operating parameters for the analyzer instrument that would result in improved calibration data. For example, for an FTIR spectrometer, one could decrease the spectral resolution to obtain a better spectral S/N for the same total scan time. Such a strategy could be advantageous if the spectral features being used for calibration have relatively low resolution. There could also be specific sets of instrument-operating parameters where the instrument response is noisy or unstable over time, in which case they can be changed to improve precision and stability of the analyzer data. [Pg.274]

FT-IR spectrometers have interferometers with scanning velocities enabling the collection of tens of spectra per second at a spectral resolution of 8 cnr1 or less. With faster data collection capabilities, FT-IR spectroscopy can be used to monitor and observe dynamic gas-phase processes. To observe such a process, interferograms are sequentially collected and stored in the memory of the system. The interferograms are then processed at the end of the data acquisition. The result of this operation is a three-dimensional data cube where each vertical slice of the cube is the spectrum for a time slice in the experiment equal to the interferogram acquisition time. [Pg.139]

P 26] Time-resolved FTIR spectroscopy was performed by operation of an infrared spectrometer in the rapid scan acquisition mode (see Figure 1.59) [110]. The effective time span between subsequent spectra was 65 ms. Further gains in time resolution can be achieved when setting the spectral resolution lower (here 8 cm4) or by using the step-scan instead of rapid-scan mode. [Pg.80]

A mirror is placed past the focusing lens to reflect the beam vertically into the flame and parallel to the spectrometer slits. The fluorescence is collected by a 10 cm focal length lens and focused onto the entrance slit of a Spex 1800-11 spectrometer operated in second order. The spectral resolution is 0.1 nm. [Pg.148]

Figure 2. BOXCARS spectrum of N1 over a 2.5-cm-diameter hexagonal fiat flame burner operating on CH,-air at 2110 K and 1-cm 1 spectral resolution. Dotted curve is the best computer fit at 2150 K, 0.8 cm 1 slit and 0.1 cm 1 Raman line-... Figure 2. BOXCARS spectrum of N1 over a 2.5-cm-diameter hexagonal fiat flame burner operating on CH,-air at 2110 K and 1-cm 1 spectral resolution. Dotted curve is the best computer fit at 2150 K, 0.8 cm 1 slit and 0.1 cm 1 Raman line-...
In the IR spectral region the noise characteristics, typical of the measurement system, have led to the development of multiplex detectors whose operation is based on the use of mathematical transformations such as the Fourier and the Hadamad. With these detection systems, an appropriate encoding (transformation) of the raw spectral signal is performed, which permits simultaneous monitoring of a wide spectral window with a single-channel sensor. A SNR (multiplex) advantage is achieved that is typically proportional to the square root of either the observation time or the number of spectral-resolution elements contained in that spectral window. [Pg.1]

This is an integral equation. To see this, introduce the spectral resolution of an inverse of an operator,... [Pg.23]


See other pages where Operator spectral resolution is mentioned: [Pg.1236]    [Pg.341]    [Pg.258]    [Pg.92]    [Pg.532]    [Pg.269]    [Pg.346]    [Pg.517]    [Pg.66]    [Pg.137]    [Pg.59]    [Pg.40]    [Pg.129]    [Pg.304]    [Pg.93]    [Pg.26]    [Pg.352]    [Pg.149]    [Pg.125]    [Pg.5]    [Pg.15]    [Pg.304]    [Pg.72]    [Pg.145]    [Pg.17]    [Pg.147]    [Pg.28]    [Pg.93]    [Pg.104]    [Pg.4]    [Pg.6]    [Pg.61]    [Pg.98]   