Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Operating conditions for

From these data, it is possible either to size a desulfurization unit, or to set the operating conditions for an existing unit. [Pg.343]

The rate of spray is deterrnined by propellant concentration, the solvent used, and valve and vapor pressure. The pressure must be high enough to dehver the product at the desired rate under the required operating conditions. For example, a windshield ice remover that is likely to be used around 0°C must be formulated to provide an adequate pressure at that temperature. Spray dryness or wetness and droplet size depend upon propellant concentration. [Pg.345]

The CER engine is operated at two conditions to simulate typical on-road driving conditions. The less severe condition measures research octane number (RON) the more severe one measures motor octane number (MON). Table 1 summarizes the operating conditions for each test. [Pg.180]

Table 9. Operating Conditions for Hydrogen Production Electrolyzers ... Table 9. Operating Conditions for Hydrogen Production Electrolyzers ...
The predominant feeds for reforming are straight-mn naphthas from cmde stills. Naphthas from catalyst crackers and naphthas from code stills are also used. Typical compositions are summarized in Table 5. Typical operating conditions for catalytic reforming are 1.135—3.548 MPa (150—500 psi),... [Pg.179]

Table 2. Operating Conditions for an Atmospheric Pressure Fluidized-Bed Combustor ... Table 2. Operating Conditions for an Atmospheric Pressure Fluidized-Bed Combustor ...
Table 34 Operating Conditions for GLC Separation of Five-membered Heterocydes with More Than One Heteroatom ... Table 34 Operating Conditions for GLC Separation of Five-membered Heterocydes with More Than One Heteroatom ...
Piston-Rod Packing Proper piston-rod packing is important. Many types are available, and the most suitable is determined by the gas handled and the operating conditions for a particular unit. [Pg.933]

Typical Operating Conditions Table 19-26 presents some typical values oF important operating conditions For the separation oF several diFFerent types oF Feed materials. In considering candidate processes For a given separation job, the table can sometimes be help-Fiil in showing that materials oF similar properties and/or economic v ahie can be treated bv electrostatic separation. [Pg.1807]

TABLE 19-26 Typical Operating Conditions for Electrostatic Separations... [Pg.1807]

A Perkin-Elmer 5000 AAS was used, with an electrically heated quartz tube atomizer. The electrolyte is continuously conveyed by peristaltic pump. The sample solution is introduced into the loop and transported to the electrochemical cell. A constant current is applied to the electrolytic cell. The gaseous reaction products, hydrides and hydrogen, fonued at the cathode, are flowed out of the cell with the carrier stream of argon and separated from the solution in a gas-liquid separator. The hydrides are transported to an electrically heated quartz tube with argon and determined under operating conditions for hydride fonuing elements by AAS. [Pg.135]

Despite the recent efforts for settling operational conditions for metal and metalloid fractionation, conventional batch sequential extraction schemes lack automation and are rather time consuming and laborious. Two additional main problems are the phase overlapping and possible re-adsorption of released elements. [Pg.243]

On the load side, the interrupter is connected through a cable to the equivalent circuit, with the required quantities of lumped resistance and reactance, to represent the motor to be tested, under a locked rotor condition. The circuit would also represent an interruption immediately after a start, to check for the most onerous operating condition for the interrupter to generate the highest surges as discussed earlier. [Pg.578]

Step 1. Selection of normal operating conditions for the regenerator system. This sets normal air blower flow and head, and expander flow and head. If the proposed installation is being designed for an existing FCC unit, only a... [Pg.173]

Allowable Departure From Specified Operating Conditions for Ciass I Test... [Pg.419]

Similarly to Eq. (2.6), fCis a proportionality constant containing fixed operating conditions, for example incident electron current density, transmission of the analyzer at the kinetic energy Ea, efficiency of the detector at the kinetic energy Ea, and the probability of the Auger transition XYZ. [Pg.40]

Table 1. Typical Chromatographic Operating Conditions for an LC Packed Column... Table 1. Typical Chromatographic Operating Conditions for an LC Packed Column...
This column requires you to indicate "Yes or "No" to whether the treatment efficiency estimate is based on actual operating data. For example, you would check Yes if the estimate is based on monitoring of influent and effluent wastes under typical operating conditions. For sequential treatment, do not indicate "Yes" or "No" in column F for a treatment step unless you have provided a treatment estimate in column E. [Pg.49]

It should be noted that although optimum operating conditions for the Aaberg exhaust system might be accurately found under ideal working conditions, the following points should be considered ... [Pg.962]

Specific ventilation recommendations were included in the CDC guidelines. The recommendations for isolation rooms serve two purposes. The first is dilution of contaminant, in this case droplet nuclei in the isolation room, The second is isolation of the space occupied by known or suspected TB patients from adjacent areas. The CDC and Conroy, et al. present recommended operating conditions for isolation rooms. These three conditions are presented in the Different Forms and Boundaries Relative to Other Types section below. [Pg.1001]


See other pages where Operating conditions for is mentioned: [Pg.4]    [Pg.5]    [Pg.300]    [Pg.1106]    [Pg.171]    [Pg.303]    [Pg.393]    [Pg.425]    [Pg.202]    [Pg.361]    [Pg.77]    [Pg.375]    [Pg.458]    [Pg.483]    [Pg.546]    [Pg.1306]    [Pg.1352]    [Pg.1691]    [Pg.1852]    [Pg.427]    [Pg.515]    [Pg.7]    [Pg.101]    [Pg.84]    [Pg.123]    [Pg.355]    [Pg.266]    [Pg.263]    [Pg.273]    [Pg.584]   


SEARCH



Operant conditioning

Operating conditions

Operational condition

© 2024 chempedia.info