Non-flowing pilot

Non-flowing pilot A pilot in which the fluid flows only just enough to enable a change in the position of the piston in the main valve it controls. During the relief cycle, there is no fluid going through the pilot. [Pg.52]

Here again, there are different designs on the market, but it is important to use non-flowing pilots so that during a relief cycle fluid does not flow through the pilot, causing impurities to damage it. [Pg.127]

The use of non-flowing pilots is highly recommended for liquids and especially flashing dual-flow applications where the amount of mixture (vapour/ liquid) is not exactly known. [Pg.127]

Primarily, it is important to always make sure to use a non-flowing pilot-type as otherwise the particles continue to flow through the pilot and will block it. [Pg.131]

In any case, it is imperative that the pilot be of a non-flowing design. A pilot is said to be non-flowing when it does not pass any fluid when the main valve state (opened or closed) does not change. The main valve may be open and flowing, but the non-flowing pilot will not flow until the valve has to... [Pg.266]

Figure 7-5B. Safety relief valve mechanism as connected to a non-flow (zero flow) pilot safety relief valve. By permission, Anderson Greenwood and Co. Figure 7-5B. Safety relief valve mechanism as connected to a non-flow (zero flow) pilot safety relief valve. By permission, Anderson Greenwood and Co.
On non-flowing-type pilot valves with a field test connection, the set pressure can be easily checked. It is recommended that the manufacturer s instructions, which should accompany the valve, be carefully followed. [Pg.40]

Thermally isolated non-flowing type pilot does not freeze up... [Pg.267]

The use of pilot-operated valves shall be considered for all backpressures above 30%. The pilot valves shall be of the non-flowing design. [Pg.273]

Pilot Type Flowing [ ] Non-flowing [ ] 22. Resilient Seat Seals ... [Pg.308]

Under carefully optimized conditions (internal flow rates, temperature, switch time, feed concentration and enantiomeric excess ee) the enantio-selective SMB-GC pilot unit furnished a total of 20 g of each enantiomer of enflurane with an enantiomeric excess of 96.6 % (time requirement not known) with N2 as carrier gas (Biressi et al., 2002b). Noteworthy is the low particle size of the non-acid-washed Chromosorb A (NAW) used ( 0.6 mm). Enflurane was introduced in the gaseous form (saturated in N2). The SMB-GC unit produced the largest amounts of single enflurane enantiomers presently available for testing of potential differences in biological activity. No comparison of throughput between the batchwise vs. the SMB process is as yet available. [Pg.295]

Barolo et al. (1998) developed a mathematical model of a pilot-plant MVC column. The model was validated using experimental data on a highly non-ideal mixture (ethanol-water). The pilot plant and some of the operating constraints are described in Table 4.13. The column is equipped with a steam-heated thermosiphon reboiler, and a water-cooled total condenser (with subcooling of the condensate). Electropneumatic valves are installed in the process and steam lines. All flows are measured on a volumetric basis the steam flow measurement is pressure- and temperature-compensated, so that a mass flow measurement is available indirectly. Temperature measurements from several trays along the column are also available. The plant is interfaced to a personal computer, which performs data acquisition and logging, control routine calculation, and direct valve manipulation. [Pg.99]

Elucidation of the non-local holistic nature of quantum theory, first discerned by Einstein [3] and interpreted as a defect of the theory, is probably the most important feature of Bohm s interpretation. Two other major innovations that flow from the Bohm interpretation are a definition of particle trajectories directed by a pilot wave and the physical picture of a stationary state. [Pg.77]

Koukou MK, Papayannakos N, Markatos NC, Bracht M, Van Veen HM, and Roskam A. Performance of ceramic membranes at elevated pressure and temperature Effect of non-ideal flow conditions in a pilot scale membrane separator. J. Membr. Sci. 1999 155(2) 241-259. [Pg.190]

This method is based on the Ohio State University Release Rate Apparatus. The specimen is injected into the environmental chamber through which a constant flow of air passes. The exposure of the specimen is determined by a radiant-heat source adjusted to produce the desired total flux on the specimen, which may be tested horizontally or vertically. Combustion may be initiated by non-piloted ignition, piloted ignition of evolved gases, or by point ignition of the surface. The changes in temperature and optical density of the gas leaving the chamber are monitored, and from the resultant data the release rate of heat and visible smoke are calculated. This aj aratus is also used to measure the rate of toxic gas release and consumption. [Pg.419]

There is also a tendency to manufacture standardized distillation apparatus, beginning with circulation stills, including also combinations of non-glass flasks and glass columns, and ending up with automatic continuous pilot plants with electro-magneticaUy operated reflux heads, level control and flow control devices (Fig. 142). The maintenance-free operation of such plants requires numerous glass valves. [Pg.222]

A schematic ofa pilot plant is shown in Figure 11.5. The pilot plant was 1500 mm wide, 900 mm long and 1500 mm high. Figure 11.6 shows the internal structure of the pilot plant in which 20 microreactors were set up in a constant-temperature bath. The inside of the pilot plant has a lower and upper step structure and it is composed of a flow control system, temperature and reaction control system and monitoring system. The flow control system consisted of non-pulsatile pumps and tanks in the lower step and electromagnetic valves and needle valves in the upper step. The withstand... [Pg.1257]

Investigations of crude oils with respect to hydrate control have thus been conducted for numerous years [9]. Most of them show results on plugging or non-plugging occurrence in laboratory facilities or pilot loops and do not allow us to preset flow conditions... [Pg.413]


See other pages where Non-flowing pilot is mentioned: [Pg.267]    [Pg.267]    [Pg.125]    [Pg.149]    [Pg.642]    [Pg.230]    [Pg.162]    [Pg.108]    [Pg.247]    [Pg.132]    [Pg.106]    [Pg.119]    [Pg.184]    [Pg.761]    [Pg.1272]    [Pg.1376]    [Pg.330]    [Pg.375]    [Pg.108]    [Pg.682]    [Pg.835]    [Pg.8]    [Pg.83]    [Pg.84]    [Pg.249]    [Pg.76]    [Pg.629]    [Pg.382]    [Pg.594]    [Pg.1725]    [Pg.567]   
See also in sourсe #XX -- [ Pg.40 , Pg.114 , Pg.115 ]