Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Noise array

One of the rationales for the noise arrays and cross-product designs advocated by Taguchi and discussed in Section 2.1 is to deliberately... [Pg.38]

Some of these differences reflect different philosophical approaches to data analysis. Taguchi s analysis of robust design experiments is frequently conducted in terms of a performance statistic, such as a signal-to-noise ratio, that is calculated for each point of the design array using data obtained from the environmental (noise) array about that point. [Pg.71]

AN EXAMPLE OF A CROSS-PRODUCT ARRAY FACTORS A, B AND C FORM THE CONTROL ARRAY (AN L4), FACTORS X, Y AND Z FORM THE (ROTATED) NOISE ARRAY (ALSO AN L4). EACH OF THE ARRAYS HAS SETTINGS I - IV. NUMBERS 15 THROUGH 22 ARE FICTIVE RESPONSE VALUES... [Pg.157]

The recent advent of large size and low noise array detectors for the near-infrared range and of powerful and fast real-time data handling computers has made feasible wide scale surveys of the astronomical sky up to 2.2 /on from the grotmd. [Pg.227]

As any conventional probe, acoustic beam pattern of ultrasound array probes can be characterized either in water tank with reflector tip, hydrophone receiver, or using steel blocks with side-drilled holes or spherical holes, etc. Nevertheless, in case of longitudinal waves probes, we prefer acoustic beam evaluation in water tank because of the great versatility of equipment. Also, the use of an hydrophone receiver, when it is possible, yields a great sensitivity and a large signal to noise ratio. [Pg.823]

Ferroelectric—polymer composite devices have been developed for large-area transducers, active noise control, and medical imaging appHcations. North American Philips, Hewlett-Packard, and Toshiba make composite medical imaging probes for in-house use. Krautkramer Branson Co. produces the same purpose composite transducer for the open market. NTK Technical Ceramics and Mitsubishi Petrochemical market ferroelectric—polymer composite materials (108) for various device appHcations, such as a towed array hydrophone and robotic use. Whereas the composite market is growing with the invention of new devices, total unit volume and doUar amounts are small compared to the ferroelectric capacitor and ferroelectric—piezoelectric ceramic markets (see Medical imaging technology). [Pg.209]

To give increased sensitivity when the analysis is not limited by chemical noise, eg, in the ms/ms mode, array detectors (15) have been developed. [Pg.540]

There are important figures of merit (5) that describe the performance of a photodetector. These are responsivity, noise, noise equivalent power, detectivity, and response time (2,6). However, there are several related parameters of measurement, eg, temperature of operation, bias power, spectral response, background photon flux, noise spectra, impedance, and linearity. Operational concerns include detector-element size, uniformity of response, array density, reflabiUty, cooling time, radiation tolerance, vibration and shock resistance, shelf life, availabiUty of arrays, and cost. [Pg.420]

Fig. 2. Behavior of electron-field emission at room temperature from Spindt-type arrays of 5000 tips per mm, beginning and ending with ultrahigh vacuum (UHV), eg, ultracontrol (UC) (a) water (b) hydrogen and (c) oxygen, where the dashed line indicates noise. To convert Pa to torr, divide by 133.3. Fig. 2. Behavior of electron-field emission at room temperature from Spindt-type arrays of 5000 tips per mm, beginning and ending with ultrahigh vacuum (UHV), eg, ultracontrol (UC) (a) water (b) hydrogen and (c) oxygen, where the dashed line indicates noise. To convert Pa to torr, divide by 133.3.
Noise Control Sound is a fluctuation of air pressure that can be detected by the human ear. Sound travels through any fluid (e.g., the air) as a compression/expansion wave. This wave travels radially outward in all directions from the sound source. The pressure wave induces an oscillating motion in the transmitting medium that is superimposed on any other net motion it may have. These waves are reflec ted, refracted, scattered, and absorbed as they encounter solid objects. Sound is transmitted through sohds in a complex array of types of elastic waves. Sound is charac terized by its amplitude, frequency, phase, and direction of propagation. [Pg.788]

In many ways, today s optical and infrared detectors are nearly perfect, with high quantum efficiency, low readout noise, high dynamic range and large arrays of pixels. However, as good as the detectors are, there are limitations that must be understood and respected in order to produce the best astronomical instm-ments and thereby, the best science. [Pg.123]

In real curvature sensors, a vibrating membrane mirror is placed at the telescope focus, followed by a collimating lens, and a lens array. At the extremes of the membrane throw, the lens array is conjugate to the required planes. The defocus distance can be chosen by adjusting the vibration amplitude. The advantage of the collimated beam is that the beam size does not depend on the defocus distance. Optical fibers are attached to the individual lenses of the lens array, and each fiber leads to an avalanche photodiode (APD). These detectors are employed because they have zero readout noise. This wavefront sensor is practically insensitive to errors in the wavefront amplitude (by virtue of normahzing the intensity difference). [Pg.190]

In order to apply RBL or GRAFA successfully some attention has to be paid to the quality of the data. Like any other multivariate technique, the results obtained by RBL and GRAFA are affected by non-linearity of the data and heteroscedast-icity of the noise. By both phenomena the rank of the data matrix is higher than the number of species present in the sample. This has been demonstrated on the PCA results obtained for an anthracene standard solution eluted and detected by three different brands of diode array detectors [37]. In all three cases significant second eigenvalues were obtained and structure is seen in the second principal component. [Pg.301]


See other pages where Noise array is mentioned: [Pg.40]    [Pg.71]    [Pg.193]    [Pg.195]    [Pg.490]    [Pg.247]    [Pg.40]    [Pg.71]    [Pg.193]    [Pg.195]    [Pg.490]    [Pg.247]    [Pg.580]    [Pg.1234]    [Pg.2963]    [Pg.391]    [Pg.391]    [Pg.207]    [Pg.207]    [Pg.216]    [Pg.63]    [Pg.290]    [Pg.113]    [Pg.142]    [Pg.426]    [Pg.427]    [Pg.428]    [Pg.431]    [Pg.432]    [Pg.435]    [Pg.436]    [Pg.398]    [Pg.374]    [Pg.53]    [Pg.258]    [Pg.200]    [Pg.148]    [Pg.150]    [Pg.287]    [Pg.57]    [Pg.353]    [Pg.120]    [Pg.30]   
See also in sourсe #XX -- [ Pg.43 ]




SEARCH



Flexible Sensor Array for a Robotic Fingertip Using Organic Thin Film Transistors (OTFT) with Minimum Interconnects and Improved Noise Tolerance

Noise focal plane array

Noise photodiode array absorbance detector

© 2024 chempedia.info