Multi-channel configurations

The determination of several analytes in the same sample is commonplace in some areas, particularly in clinical chemistry. Multi-parameter designs are thus of great Interest to the automation of laboratory procedures, to which commercially available analysers, with the exception of some rather specific examples, are perfectly suited. In continuous segmented analysers, the term [Pg.141]

Automatic multi-channel continuous segmented analysers are based on the foliowing basic principles (Fig. 5.10)  [Pg.142]

The second option is typically represented by the Technicon SMAC (Sequential Multiple Analyzer plus Computer) I and II, which are expensive and complex analytical systems capable of determining up to 20 parameters per sample at a rate of 150 samples per hour [27]. These analysers consist of the following components, all of which are governed by a central computer  [Pg.142]

Because of Its high cost and labour demands —It requires the almost continuous attention of one or two operators— the SMAC Is only affordable by large hospitals requiring high throughputs. [Pg.143]


Kinetic measurements with bipolar electrochemical cells were made using the same experimental setup as with single-pellet cells described in Section III.2.H and seen in Figure 7. Two types of bipolar electrochemical cells have been developed in our laboratory, a ring-shaped and a multi-channel configuration. As shown in Figure 28,... [Pg.239]

Highlights potential hazards from adjacent non-related systems (e.g. heating pipes near sensitive electronic equipment, hot air leaks, drips from pipes, multi-channels through same connectors, EMI effects on multi-channel configurations, etc.). [Pg.291]

For a short description of the aims of experimental concentration cycling with respect to citraconic acid formation, see [13]. It is also demonstrated there that the response to rectangular concentration pulses for a given reactor configuration of a multi-channel-stack micro reactor can be improved by increasing the number of platelets and channels (while reducing their diameter). Such behavior was shovm for an incompressible fluid, i.e. is not solely related to the above-mentioned reaction. [Pg.322]

The input multiplexer was designed to allow multi-channel capability and was configured to monitor both potential and current noise fluctuations sequentially on a maximum of eight pairs of samples. [Pg.38]

The shape resonances have been described by Feshbach in elastic scattering cross-section for the processes of neutron capture and nuclear fission [7] in the cloudy crystal ball model of nuclear reactions. These scattering theory is dealing with configuration interaction in multi-channel processes involving states with different spatial locations. Therefore these resonances can be called also Feshbach shape resonances. These resonances are a clear well established manifestation of the non locality of quantum mechanics and appear in many fields of physics and chemistry [8,192] such as the molecular association and dissociation processes. [Pg.25]

Y. Komninos, C.A. Nicolaides, Multi-channel reaction matrix theory and configuration-interaction in the discrete and in the continuous spectrum. Inclusion of closed channels and derivation of quantum defect theory, Z. Phys. D 4 (1987) 301. [Pg.98]

In another configuration of instmmentation, irradiation of white light onto the electrode surface and detection of reflected light by the use of a multi-channel detector (such as CCD or photo-diode array) through a grating monochromator makes multi-channel measurement possible [21]. [Pg.57]

Traditionally, the design of the injection channel has always been in the form of a cross. A limitation of this configuration is that it is only capable of providing discrete, fixed-volume samples. However, some applications require the delivery of different sample volumes to the detection and separation processes. The unique multi-T configuration injection system [3] has the ability to simulate the functions of the cross, double-T, and triple-T systems through appropriate manipulations of the electric field within its various channels. Figure 7 shows the experimental and numerical simulation results of the proposed multi-T form injection system. [Pg.843]

In contrast, the branch feed configuration employs feed lines that are nominally of equal length. Therefore the phase relationships of the radiating elements are maintained over a wide span of frequencies. This provides vertical patterns with stable beam tilt, a requirement for multi-channel applications. [Pg.1552]

Lloyd, G.D. et al. Re-configurable, multi-channel, high-speed FBG strain sensing system for vibration analysis in oil risers. 17th Intern. Conf. on Optical Fibre Sensors (OFS-17), Bruges, Belgium, SPIE-Vol. 5855 (2005) pp. 218-221... [Pg.365]

In addition to the planar geometry, inorganic membranes can also be produced in flat disk, tubular (dead-end or not), monolithic multi-channel, or hollow fiber configurations as shown in Figure 1.6. Disk membranes are often used in the laboratory because they can easily be fabricated by the conventional pressing method. In the case of tubes, they can be assembled in a module containing a number of tubes connected to a single manifold system. [Pg.9]

Hydrogenation of a methyl styrene to cumene Multi channel stmcture with T-configuration Useful for gas/ liquid or Uquid /liquid reactions... [Pg.28]


See other pages where Multi-channel configurations is mentioned: [Pg.141]    [Pg.171]    [Pg.72]    [Pg.141]    [Pg.171]    [Pg.72]    [Pg.224]    [Pg.235]    [Pg.345]    [Pg.28]    [Pg.172]    [Pg.202]    [Pg.490]    [Pg.192]    [Pg.230]    [Pg.231]    [Pg.36]    [Pg.685]    [Pg.166]    [Pg.259]    [Pg.71]    [Pg.75]    [Pg.80]    [Pg.52]    [Pg.250]    [Pg.457]    [Pg.1832]    [Pg.12]    [Pg.20]    [Pg.263]    [Pg.44]    [Pg.408]    [Pg.291]    [Pg.73]    [Pg.101]    [Pg.130]   