Mass spectrometry sample introduction

Liquid membrane enrichment coupled to mass spectrometry. Membrane introduction mass spectrometry (MIMS) is an established method of sample... [Pg.579]

In this discussion, only inert gases such as argon or neon are used as examples because they are monatomic, which simplifies description of the excitation. The introduction of larger molecules into a discharge is discussed in later chapters concerning examination of samples by mass spectrometry. [Pg.30]

The advent of atmospheric-pressure ionization (API) provided a method of ionizing labile and nonvolatile substances so that they could be examined by mass spectrometry. API has become strongly linked to HPLC as a basis for ionizing the eluant on its way into the mass spectrometer, although it is also used as a stand-alone inlet for introduction of samples. API is important in thermospray, plasmaspray, and electrospray ionization (see Chapters 8 and 11). [Pg.61]

To examine a sample by inductively coupled plasma mass spectrometry (ICP/MS) or inductively coupled plasma atomic-emission spectroscopy (ICP/AES) the sample must be transported into the flame of a plasma torch. Once in the flame, sample molecules are literally ripped apart to form ions of their constituent elements. These fragmentation and ionization processes are described in Chapters 6 and 14. To introduce samples into the center of the (plasma) flame, they must be transported there as gases, as finely dispersed droplets of a solution, or as fine particulate matter. The various methods of sample introduction are described here in three parts — A, B, and C Chapters 15, 16, and 17 — to cover gases, solutions (liquids), and solids. Some types of sample inlets are multipurpose and can be used with gases and liquids or with liquids and solids, but others have been designed specifically for only one kind of analysis. However, the principles governing the operation of inlet systems fall into a small number of categories. This chapter discusses specifically substances that are normally liquids at ambient temperatures. This sort of inlet is the commonest in analytical work. [Pg.103]

The main advantages of the ms/ms systems are related to the sensitivity and selectivity they provide. Two mass analyzers in tandem significantly enhance selectivity. Thus samples in very complex matrices can be characterized quickly with Htde or no sample clean-up. Direct introduction of samples such as coca leaves or urine into an ms or even a gc/lc/ms system requires a clean-up step that is not needed in tandem mass spectrometry (28,29). Adding the sensitivity of the electron multiplier to this type of selectivity makes ms/ms a powerhil analytical tool, indeed. It should be noted that introduction of very complex materials increases the frequency of ion source cleaning compared to single-stage instmments where sample clean-up is done first. [Pg.405]

Every mass spectrometer consists of four principal components (Fig 1) (1) the source, where a beam of gaseous ions are produced from the sample (2) the analyzer, where the ion beam is resolved into its characteristic mass species (3) the detector, where the ions are detected and their intensities measured (4) the sample introduction system to vaporize and admit the sample into the ion source. There is a wide variety in each of these components and only those types which are relevant to analytical and organic mass spectrometry will be emphasized in this survey. The instrumentation... [Pg.37]

Haddon, W. E. and Harden, L. A., Advantages of particle beam sample introduction for analysis of thermally sensitive natural products by mass spectrometry , in Proceedings of the 39th ASMS Conference on Mass Spectrometry and Allied Topics, Nashville, TN, May 19-24, 1991, pp. 1316-1317. [Pg.185]

Moens L, Verreft P, Boonen S, Vanhaecke F and Dams R (1995) Solid sampling electrothermal vaporization for sample introduction in inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry. Spectrochim Acta 508 463-475. Mooijman KA, In t Veld PH, Hoekstra JA, Heisterkamp SH, Havelaar AH, Notermans SHW, Roberts D, Griepink B, Maier E (1992) Development of Microbiological Reference Materials. European Commission Report EUR 14375 EN, Community Bureau of Reference, Brussels. [Pg.46]

Gray AL (1985). Solid sample introduction by laser ablation for inductively coupled plasma source mass spectrometry. Analyst 110 551-556... [Pg.56]

The use of the particle-beam interface for introduction of samples into a mass spectrometer (PB-MS), without chromatographic separation, was shown by Bonilla [55] to be a useful method for analysis of semi-volatile and nonvolatile additives in PC and PC/PBT blends. The method uses the full power of mass spectrometry to identify multiple additives in a single matrix. The usefulness, speed and simplicity of this approach were illustrated for AOs, UVAs, FRs, slip agents and other additives. [Pg.362]

Also, direct determination of additives by means of laser desorption in solid polymeric materials rather than in polymer extracts has been reported [266], Takayama et al. [267] have described the direct detection of additives on the surface of LLDPE/(Chimassorb 944 LD and Irgafos P-EPQ) after matrix (THAP)-coating. As shown in Scheme 7.13, direct inlet mass spectrometry is also applicable to transfer TLC-MS and TLC-MS/MS analyses without the need for prior analysis. For direct sample introduction a small amount of the selected... [Pg.413]

Smith and Udseth [154] first described SFE-MS in 1983. Direct fluid injection (DFT) mass spectrometry (DFT-MS, DFI-MS/MS) utilises supercritical fluids for solvation and transfer of materials to a mass-spectrometer chemical ionisation (Cl) source. Extraction with scC02 is compatible with a variety of Cl reagents, which allow a sensitive and selective means for ionising the solute classes of interest. If the interfering effects of the sample matrix cannot be overcome by selective ionisation, techniques based on tandem mass spectrometry can be used [7]. In these cases, a cheaper and more attractive alternative is often to perform some form of chromatography between extraction and detection. In SFE-MS, on-line fractionation using pressure can be used to control SCF solubility to a limited extent. The main features of on-line SFE-MS are summarised in Table 7.20. It appears that the direct introduction into a mass spectrometer of analytes dissolved in supercritical fluids without on-line chromatography has not actively been pursued. [Pg.451]

As SFC provides gaseous sample introduction to the plasma and thus near-100 % analyte transport efficiency, coupling SFC with plasma mass spectrometry offers the potential of a highly sensitive, element-selective chromatographic detector for many elements. Helium high-efficiency microwave-induced plasma has been proposed as an element-selective detector for both pSFC and cSFC [467,468] easy hyphenation of pSFC to AED has been reported [213]. [Pg.488]

Different analytical procedures have been developed for direct atomic spectrometry of solids applicable to inorganic and organic materials in the form of powders, granulate, fibres, foils or sheets. For sample introduction without prior dissolution, a sample can also be suspended in a suitable solvent. Slurry techniques have not been used in relation to polymer/additive analysis. The required amount of sample taken for analysis typically ranges from 0.1 to 10 mg for analyte concentrations in the ppm and ppb range. In direct solid sampling method development, the mass of sample to be used is determined by the sensitivity of the available analytical lines. Physical methods are direct and relative instrumental methods, subjected to matrix-dependent physical and nonspectral interferences. Standard reference samples may be used to compensate for systematic errors. The minimum difficulties cause INAA, SNMS, XRF (for thin samples), TXRF and PIXE. [Pg.626]

D. Beauchemin, D.C. Gregoire, D. Gunther, V. Karanassios, J.-M. Mermet and T.J. Woods (eds), Discrete Sample Introduction Techniques for Inductively Coupled Plasma Mass Spectrometry, Elsevier, Amsterdam (2000). [Pg.677]

Bjorn E, Freeh W, Hoffmann E, Liidke C (1998) Investigation and quantification of spectroscopic interferences from polyatomic species in inductively coupled plasma mass spectrometry using electrothermal vaporization or pneumatic nebulization for sample introduction. Spectrochim Acta 53B 1766... [Pg.237]

Elemental Speciation - New Approaches for Trace Element Analysis Discrete Sample Introduction Techniques for Inductively Coupled Plasma Mass Spectrometry... [Pg.779]

Direct introduction of a sample, either in solid or liquid state, in the ion source of a mass spectrometer may be achieved through two procedures the first one is based on the use of a direct insertion probe (DIP) the second one necessitates a direct exposure probe (DEP). Direct introduction followed by heating of the sample in the ion source of the mass spectrometer is also known as direct temperature resolved mass spectrometry (DTMS). [Pg.101]

In addition to GC/MS, high performance liquid chromatography (HPLC/MS) has been used to analyse natural resins in ancient samples, particularly for paint varnishes containing mastic and dammar resins [34]. A partial limitation of chromatographic techniques is that they do not permit the analysis of the polymeric fraction or insoluble fraction that may be present in the native resins or formed in the course of ageing. Techniques based on the direct introduction of the sample in the mass spectrometer such as direct temperature resolved mass spectrometry (DTMS), direct exposure mass spectrometry (DE-MS) and direct inlet mass spectrometry (DI-MS), and on analytical pyrolysis (Py-GC/MS), have been employed as complementary techniques to obtain preliminary information on the... [Pg.217]

Nevertheless, the introduction of time-of-flight (ToF) analysers for SIMS analyses at the beginning of the 1980s, as well as the recent development of liquid ion sources delivering cluster projectiles now permit the analysis of organic materials with high sensitivity and selectivity. Moreover, thanks to its excellent lateral resolution (in the order of micrometres), and its minimal sample preparation, ToF-SIMS has become the reference technique for chemical imaging by mass spectrometry. [Pg.433]


See other pages where Mass spectrometry sample introduction is mentioned: [Pg.434]    [Pg.2826]    [Pg.2827]    [Pg.403]    [Pg.97]    [Pg.9]    [Pg.598]    [Pg.321]    [Pg.320]    [Pg.734]    [Pg.736]    [Pg.57]    [Pg.378]    [Pg.397]    [Pg.406]    [Pg.409]    [Pg.412]    [Pg.473]    [Pg.538]    [Pg.649]    [Pg.40]    [Pg.371]    [Pg.36]    [Pg.104]    [Pg.43]    [Pg.78]    [Pg.98]    [Pg.126]   
See also in sourсe #XX -- [ Pg.322 ]

See also in sourсe #XX -- [ Pg.577 ]

See also in sourсe #XX -- [ Pg.108 ]




SEARCH



Direct sample introduction mass spectrometry

Direct sample introduction mass spectrometry materials

Mass spectrometry introduction

Mass spectrometry sample introduction system

Sample Introduction and Solvent Systems for Electrospray Mass Spectrometry

Sample introduction

Sample mass

Sample mass spectrometry

Sample spectrometry

© 2024 chempedia.info