Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mass spectrometry phase

As the temperatures of the distillation cuts increase, the problems get more complicated to the point where preliminary separations are required that usually involve liquid phase chromatography (described earlier). This provides, among others, a saturated fraction and an aromatic fraction. Mass spectrometry is then used for each of these fractions. [Pg.53]

Other techniques for predicting the cetane number rely on chemical analysis (Glavinceski et al., 1984) (Pande et al., 1990). Gas phase chromatography can be used, as can NMR or even mass spectrometry (refer to 3.2.1.l.b and 3.2.2.2). [Pg.220]

An important application of these results lies in the analysis of food flavorings using a combination of gas-phase chromatography and mass spectrometry (121, 122). Similarly, metabolic products of chlo-methiazole have been characterized (123). [Pg.348]

Fast-Atom Bombardment (FAB) and Liquid-Phase Secondary Ion Mass Spectrometry (LSIMS) Ionization... [Pg.17]

The basic principles of fast-atom bombardment (FAB) and liquid-phase secondary ion mass spectrometry (LSIMS) are discussed only briefly here because a fuller description appears in Chapter 4. This chapter focuses on the use of FAB/LSIMS as part of an interface between a liquid chromatograph (LC) and a mass spectrometer (MS), although some theory is presented. [Pg.81]

LSIMS. liquid-phase secondary ion mass spectrometry... [Pg.446]

TaF has been characterized by ir, Raman, x-ray diffraction, and mass spectrometry (3,11,12). TaF has been used as a superacid catalyst for the conversion of CH to gasoline-range hydrocarbons (qv) (12) in the manufacture of fluoride glass and fluoride glass optical fiber preforms (13), and incorporated in semiconductor devices (14). TaF is also a catalyst for the Hquid-phase addition of HF to polychlorinated ethenes (15). The chemistry of TaF has been reviewed (1,16—19). Total commercial production for TaF is thought to be no more than a few hundred kilograms aimuaHy. [Pg.252]

Hypochlorous acid and chlorine monoxide coexist in the vapor phase (78—81). Vapor pressure measurements of aqueous HOCl solutions show that HOCl is the main chlorine species in the vapor phase over <1% solutions (82), whereas at higher concentrations, CI2O becomes dominant (83). The equihbtium constant at 25°C for the gas-phase reaction, determined by ir and uv spectrophotometry and mass spectrometry, is ca 0.08 (9,66,67,69). The forward reaction is much slower than the reverse reaction. [Pg.467]

Solid-phase microextraction (SPME) was used for headspace sampling. The FFA were extracted from the headspace with PA, Car/PDMS, and CW/DVB fibers. It was examined whether addition of salt (NaCl) and decreasing the pH by addition of sulphuric acid (H SO ) increased the sensitivity. FFA were analyzed using gas chromatography coupled to mass spectrometry in selected ion monitoring. [Pg.172]

A liquid chromatography-mass spectrometry (LC-MS) method that can quantitatively analyze urinar y normal and modified nucleosides in less than 30 min with a good resolution and sufficient sensitivity has been developed. Nineteen kinds of normal and modified nucleosides were determined in urine samples from 10 healthy persons and 18 breast cancer patients. Compounds were separ ated on a reverse phase Kromasil C18 column (2.1 mm I.D.) by isocratic elution mode using 20 mg/1 ammonium acetate - acetonitrile (97 3 % v/v) at 200 p.l/min. A higher sensitivity was obtained in positive atmospheric pressure chemical ionization mode APCI(-i-). [Pg.351]

The liquid chromatography - tandem mass spectrometry (LC/MS/MS) technique was proposed for the determination of corticosteroids in plasma and cerebrospinal fluid (CSF, liquor) of children with leucosis. Preliminai y sample prepai ation included the sedimentation of proteins, spinning and solid-phase extraction. MS detection was performed by scanning selected ions, with three chai acteristic ions for every corticosteroids. The limit of detection was found 80 pg/ml of plasma. [Pg.351]

Unlike the stable molecule N2O, the sulfur analogue N2S decomposes above 160 K. In the vapour phase N2S has been detected by high-resolution mass spectrometry. The IR spectrum is dominated by a very strong band at 2040 cm [v(NN)]. The first ionization potential has been determined by photoelectron spectroscopy to be 10.6 eV. " These data indicate that N2S resembles diazomethane, CH2N2, rather than N2O. It decomposes to give N2 and diatomic sulfur, S2, and, hence, elemental sulfur, rather than monoatomic sulfur. Ab initio molecular orbital calculations of bond lengths and bond energies for linear N2S indicate that the resonance structure N =N -S is dominant. [Pg.82]

Sulfurous acid has never been isolated as a pure compound, although it has recently been detected in the gas phase by neutralization reionization mass spectrometry (NRMS) following the facile dissociative ionization (70 eV) of either diethyl sulfite or ethanesulfonic acid " ... [Pg.717]

Cr OCh has been observed in the gaseous phase by means of mass spectrometry/ ... [Pg.1023]

This technique provides quantitative information about tautomeric equilibria in the gas phase. The results are often complementary to those obtained by mass spectrometry (Section VII,E). In principle, gas-phase proton affinities, as determined by ICR, should provide quantitative data on tautomeric equilibria. The problem is the need to correct the measured values for the model compounds, generally methyl derivatives, by the so-called N-, 0-, or S-methylation effect. Since the difference in stability between tautomers is generally not too large (otherwise determination of the most stable tautomer is trivial) and since the methylation effects are difficult to calculate, the result is that proton affinity measurements allow only semi-quantitative estimates of individual tautomer stabilities. This is a problem similar to but more severe than that encountered in the method using solution basicities (76AHCS1, p. 20). [Pg.52]

ONLINE REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY-CAPILLARY ZONE ELECTROPHORESIS - MASS SPECTROMETRY... [Pg.211]

Mass spectrometry (MS) is increasingly being combined with reverse phase HPLC or CZE in order to add an additional dimension to the data that a traditional detection system would not provide. A two-dimensional EC-CZE system with mass... [Pg.211]

C. Aguilar, I. Feirer, R Bonnll, R. M. Marce and D. Barcelo, Monitoring of pesticides in river water based on samples previously stored in polymeric cartridges followed by on-line solid-phase extraction-liquid cliromatography-diode array detection and confirmation by atmospheric pressure chemical ionization mass spectrometry . Anal. Chim. Acta 386 237-248 (1999). [Pg.374]


See other pages where Mass spectrometry phase is mentioned: [Pg.1331]    [Pg.2390]    [Pg.2390]    [Pg.586]    [Pg.61]    [Pg.253]    [Pg.261]    [Pg.287]    [Pg.49]    [Pg.201]    [Pg.509]    [Pg.535]    [Pg.135]    [Pg.630]    [Pg.247]    [Pg.64]    [Pg.193]    [Pg.415]    [Pg.436]    [Pg.50]    [Pg.51]    [Pg.189]    [Pg.299]    [Pg.253]    [Pg.337]   
See also in sourсe #XX -- [ Pg.105 ]




SEARCH



Cationization Mass Spectrometry for Condensed-Phase Samples

Headspace solid phase microextraction-gas chromatography-mass spectrometry

Liquid chromatography-mass spectrometry mobile phase

Mass spectrometry , gas-phase

Mass spectrometry mobile phase conditions with

Mass spectrometry samples solid-phase extraction

Mass spectrometry solid phase synthesis

Mass spectrometry solid-phase peptide

Mass spectrometry solid-phase peptide synthesis

Mobile phase mass spectrometry

Reverse-phase liquid chromatography mass spectrometry

Reversed-phase liquid chromatography-mass spectrometry

Solid-phase extraction-mass spectrometry

Vapor phase decomposition inductively coupled plasma mass spectrometry

© 2024 chempedia.info