Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mass liquid-phase

However, a note of caution should be added. In many multiphase reaction systems, rates of mass transfer between different phases can be just as important or more important than reaction kinetics in determining the reactor volume. Mass transfer rates are generally higher in gas-phase than liquid-phase systems. In such situations, it is not so easy to judge whether gas or liquid phase is preferred. [Pg.45]

In the first class, azeotropic distillation, the extraneous mass-separating agent is relatively volatile and is known as an entrainer. This entrainer forms either a low-boiling binary azeotrope with one of the keys or, more often, a ternary azeotrope containing both keys. The latter kind of operation is feasible only if condensation of the overhead vapor results in two liquid phases, one of which contains the bulk of one of the key components and the other contains the bulk of the entrainer. A t3q)ical scheme is shown in Fig. 3.10. The mixture (A -I- B) is fed to the column, and relatively pure A is taken from the column bottoms. A ternary azeotrope distilled overhead is condensed and separated into two liquid layers in the decanter. One layer contains a mixture of A -I- entrainer which is returned as reflux. The other layer contains relatively pure B. If the B layer contains a significant amount of entrainer, then this layer may need to be fed to an additional column to separate and recycle the entrainer and produce pure B. [Pg.81]

As the temperatures of the distillation cuts increase, the problems get more complicated to the point where preliminary separations are required that usually involve liquid phase chromatography (described earlier). This provides, among others, a saturated fraction and an aromatic fraction. Mass spectrometry is then used for each of these fractions. [Pg.53]

When oil and gas are produced simultaneously into a separator a certain amount (mass fraction) of each component (e.g. butane) will be in the vapour phase and the rest in the liquid phase. This can be described using phase diagrams (such as those described in section 4.2) which describe the behaviour of multi-component mixtures at various temperatures and pressures. However to determine how much of each component goes into the gas or liquid phase the equilibrium constants (or equilibrium vapour liquid ratios) K must be known. [Pg.243]

Densification during liquid-phase sintering occurs in tliree stages. Initially, liquid fonns at particle intersections and redistributes tliroughout the particulate mass under the influence of the capillary action. Shear stresses due to the... [Pg.2771]

The methods listed thus far can be used for the reliable prediction of NMR chemical shifts for small organic compounds in the gas phase, which are often reasonably close to the liquid-phase results. Heavy elements, such as transition metals and lanthanides, present a much more dilficult problem. Mass defect and spin-coupling terms have been found to be significant for the description of the NMR shielding tensors for these elements. Since NMR is a nuclear effect, core potentials should not be used. [Pg.253]

Fast-Atom Bombardment (FAB) and Liquid-Phase Secondary Ion Mass Spectrometry (LSIMS) Ionization... [Pg.17]

The basic principles of fast-atom bombardment (FAB) and liquid-phase secondary ion mass spectrometry (LSIMS) are discussed only briefly here because a fuller description appears in Chapter 4. This chapter focuses on the use of FAB/LSIMS as part of an interface between a liquid chromatograph (LC) and a mass spectrometer (MS), although some theory is presented. [Pg.81]

Mixtures passed through special columns (chromatography) in the gas phase (GC) or liquid phase (LC) can be separated into their individual components and analyzed qualitatively and/or quantitatively. Both GC and LC analyzers can be directly coupled to mass spectrometers, a powerful combination that can simultaneously separate and identify components of mixtures. [Pg.252]

It is worth noting that some of these methods are both an inlet system to the mass spectrometer and an ion source at the same time and are not used with conventional ion sources. Thus, with electrospray, the process of removing the liquid phase from the column eluant also produces ions of any emerging mixture components, and these are passed straight to the mass spectrometer analyzer no separate ion source is needed. The particle beam method is different in that the liquid phase is removed, and any residual mixture components are passed into a conventional ion source (often electron ionization). [Pg.263]

LSIMS. liquid-phase secondary ion mass spectrometry... [Pg.446]

Equation 28 and its liquid-phase equivalent are very general and valid in all situations. Similarly, the overall mass transfer coefficients may be made independent of the effect of bulk fiux through the films and thus nearly concentration independent for straight equilibrium lines ... [Pg.23]

OL Height of one overall liquid-phase mass-transfer unit m ft... [Pg.589]

Vl Liquid-phase mass-transfer coefficient for dilute systems kmoP[(s-m )(kmoPm )] or ni/s (lbmol)/[(h-tF)(lbmol/tt )J or tt/h... [Pg.589]

Transfer of material between phases is important in most separation processes in which two phases are involved. When one phase is pure, mass transfer in the pure phase is not involved. For example, when a pure liqmd is being evaporated into a gas, only the gas-phase mass transfer need be calculated. Occasionally, mass transfer in one of the two phases may be neglec ted even though pure components are not involved. This will be the case when the resistance to mass transfer is much larger in one phase than in the other. Understanding the nature and magnitudes of these resistances is one of the keys to performing reliable mass transfer. In this section, mass transfer between gas and liquid phases will be discussed. The principles are easily applied to the other phases. [Pg.600]

For the liquid-phase mass-transfer coefficient /cl, the effects of total system pressure can be ignored for all practical purposes. Thus, when using Kq and /cl for the design of gas absorbers or strippers, the primary pressure effects to consider will be those which affect the equilibrium curves and the values of m. If the pressure changes affect the hydrodynamics, then Icq, and a can all change significantly. [Pg.610]

With regard to the liqiiid-phase mass-transfer coefficient, Whitney and Vivian found that the effect of temperature upon coiild be explained entirely by variations in the liquid-phase viscosity and diffusion coefficient with temperature. Similarly, the oxygen-desorption data of Sherwood and Holloway [Trans. Am. Jnst. Chem. Eng., 36, 39 (1940)] show that the influence of temperature upon Hl can be explained by the effects of temperature upon the liquid-phase viscosity and diffusion coefficients. [Pg.610]

It is important to recognize that the effects of temperature on the liquid-phase diffusion coefficients and viscosities can be veiy large and therefore must be carefully accounted for when using /cl or data. For liquids the mass-transfer coefficient /cl is correlated in terms of design variables by relations of the form... [Pg.610]

Fits some, but not all, data. Low mass transfer rate. = mean molecular weight of dispersed phase tf= formation time of drop. k[, i = mean dispersed liquid phase M.T. coefficient kmole/[s - m" (mole fraction)]. [Pg.613]

Z. 5-25-Y, large huhhles = AA = 0.42 (NG..) Wi dy > 0.25 cm Dr luterfacial area 6 fig volume dy [E] Use with arithmetic concentration difference, ffg = fractional gas holdup, volume gas/total volume. For large huhhles, k is independent of bubble size aud independent of agitation or liquid velocity. Resistance is entirely in liquid phase for most gas-liquid mass transfer. [79][91] p. 452 [109] p. 119 [114] p. 249... [Pg.615]

Extrapolation of KgO data for absorption and stripping to conditions other than those for which the origin measurements were made can be extremely risky, especially in systems involving chemical reactions in the liquid phase. One therefore would be wise to restrict the use of overall volumetric mass-transfer-coefficient data to conditions not too far removed from those employed in the actual tests. The most reh-able data for this purpose would be those obtained from an operating commercial unit of similar design. [Pg.625]

Equations (13-111) to (13-114), (13-118) and (13-119), contain terms, Njj, for rates of mass transfer of components from the vapor phase to the liquid phase (rates are negative if transfer is from the liquid phase to the vapor phase). These rates are estimated from diffusive and bulk-flow contributions, where the former are based on interfacial area, average mole-fraction driving forces, and mass-... [Pg.1291]

More often than not the rate at which residual absorbed gas can be driven from the liqmd in a stripping tower is limited by the rate of a chemical reaction, in which case the liquid-phase residence time (and hence, the tower liquid holdup) becomes the most important design factor. Thus, many stripper-regenerators are designed on the basis of liquid holdup rather than on the basis of mass transfer rate. [Pg.1352]


See other pages where Mass liquid-phase is mentioned: [Pg.149]    [Pg.149]    [Pg.2826]    [Pg.253]    [Pg.257]    [Pg.261]    [Pg.287]    [Pg.200]    [Pg.542]    [Pg.589]    [Pg.589]    [Pg.589]    [Pg.589]    [Pg.602]    [Pg.604]    [Pg.604]    [Pg.617]    [Pg.624]    [Pg.1050]    [Pg.1291]    [Pg.1291]    [Pg.1320]    [Pg.1349]   
See also in sourсe #XX -- [ Pg.80 , Pg.81 , Pg.82 , Pg.86 , Pg.91 , Pg.108 , Pg.127 , Pg.134 , Pg.167 , Pg.178 ]




SEARCH



Diffusion liquid-phase mass

Heat and Mass Exchange Intensification in Fast Liquid-phase Processes

Liquid chromatography-mass mobile phase

Liquid chromatography-mass phase

Liquid chromatography-mass spectrometry mobile phase

Liquid phase mass transfer problems

Liquid-Phase Mass Transfer with Chemical Reactions

Liquid-phase chemical reaction rates, mass transfer effects

Liquid-phase mass balance

Mass Balances for the Gas and Liquid Bulk Phases

Mass balance liquid phase differential reactor

Mass transfer coefficient liquid phase

Mass transfer coefficient liquid phase diffusivity effect

Reverse-phase liquid chromatography mass spectrometry

Reversed-phase liquid chromatography-mass

Reversed-phase liquid chromatography-mass spectrometry

© 2024 chempedia.info