However, for water analysis, reverse-phase liquid chromatography is more suitable but its coupling with GC has some drawbacks because of the partly aqueous effluent. Several systems have been developed (88, 89) and applied to determine pollutants in water. [Pg.361]

Another possibility of constructing a chiral membrane system is to prepare a solution of the chiral selector which is retained between two porous membranes, acting as an enantioselective liquid carrier for the transport of one of the enantiomers from the feed solution of the racemate to the receiving side (Fig. 1-5). This system is often referred to as membrane-assisted separation. The selector should not be soluble in the solvent used for the elution of the enantiomers, whose transport is driven by a gradient in concentration or pH between the feed and receiving phases. As a drawback common to all these systems, it should be mentioned that the transport of one enantiomer usually decreases when the enantiomer ratio in the permeate diminishes. Nevertheless, this can be overcome by designing a system where two opposite selectors are used to transport the two enantiomers of a racemic solution simultaneously, as it was already applied in W-tube experiments [171]. [Pg.15]

In general, high selectivities can be obtained in liquid membrane systems. However, one disadvantage of this technique is that the enantiomer ratio in the permeate decreases rapidly when the feed stream is depleted in one enantiomer. Racemization of the feed would be an approach to tackle this problem or, alternatively, using a system containing the two opposite selectors, so that the feed stream remains virtually racemic [21]. Another potential drawback of supported enantioselective liquid membranes is the application on an industrial scale. Often a complex multistage process is required in order to achieve the desired purity of the product. This leads to a relatively complicated flow scheme and expensive process equipment for large-scale separations. [Pg.132]

One drawback of the spring is the need for relatively low shaft speeds because of a natural tendency of the components to distort at high surface speeds. This makes the spring push harder on one side of the seal than the other, resulting in an uneven liquid film between the faces. This causes excessive leakage and wears at the seal. [Pg.946]

The most widely used reference electrode, due to its ease of preparation and constancy of potential, is the calomel electrode. A calomel half-cell is one in which mercury and calomel [mercury(I) chloride] are covered with potassium chloride solution of definite concentration this may be 0.1 M, 1M, or saturated. These electrodes are referred to as the decimolar, the molar and the saturated calomel electrode (S.C.E.) and have the potentials, relative to the standard hydrogen electrode at 25 °C, of 0.3358,0.2824 and 0.2444 volt. Of these electrodes the S.C.E. is most commonly used, largely because of the suppressive effect of saturated potassium chloride solution on liquid junction potentials. However, this electrode suffers from the drawback that its potential varies rapidly with alteration in temperature owing to changes in the solubility of potassium chloride, and restoration of a stable potential may be slow owing to the disturbance of the calomel-potassium chloride equilibrium. The potentials of the decimolar and molar electrodes are less affected by change in temperature and are to be preferred in cases where accurate values of electrode potentials are required. The electrode reaction is... [Pg.551]

The conversion of RBr will decline when the catalyst-rich liquid phase is reused, mainly due to the accumulation of NaBr and lose of catalyst. This drawback should be overcome before the technique of solid-Hquid-liquid catalysis to be commercialized. [Pg.184]

A slight disadvantage of the concept is phase separation, as the phases are thoroughly inter-mixed. In contrast to liquid/liquid dispersion, the gas/liquid separation should be, however, not nearly as troublesome. Another more serious drawback stems from the disperse nature of the systems involving a size distribution of the initial bubbles in the continuous liquid, which can be rather broad. By this... [Pg.580]

Another major drawback stems from the disperse nature of the system itself involving a size distribution of the bubbles in the continuous liquid, which can be broad. The interface is not as defined as for two-phase continuous reactors, as described in Section 5.1.1. However, in the case of making foams, regular micro flow structures, such as hexagon flow, were described [22]. [Pg.590]

An LCD is a ubiquitous electronic display. Now, it is widely distributed among human daily life, like mobile phones, TV, and personal computers. The LCD has, however, a drawback, i.e., slower response than a plasma display or an electroluminescene display. Recently we have first succeeded in combination of a nanoparticle technology with the LCD technology, which realized fast response of the LCD [45,235,236]. Thus we have found a phenomenon, i.e., a frequency modulation of the LCD doped with metallic nanoparticles. Since the frequency modulation, or electro-optic property depends on the kind of metals, we have prepared AgPd bimetallic nanoparticles protected with a typical liquid crystal molecule, 4-cyano-4 -pentylbiphenyl (5CB) to investigate the electro-optic property [45,235,236]. [Pg.71]

In this chapter, we describe some of the more widely used and successful kinetic techniques involving controlled hydrodynamics. We briefly discuss the nature of mass transport associated with each method, and assess the attributes and drawbacks. While the application of hydrodynamic methods to liquid liquid interfaces has largely involved the study of spontaneous processes, several of these methods can be used to investigate electrochemical processes at polarized ITIES we consider these applications when appropriate. We aim to provide an historical overview of the field, but since some of the older techniques have been reviewed extensively [2,3,13], we emphasize the most recent developments and applications. [Pg.333]

Although the Lewis cell was introduced over 50 years ago, and has several drawbacks, it is still used widely to study liquid-liquid interfacial kinetics, due to its simplicity and the adaptable nature of the experimental setup. For example, it was used recently to study the hydrolysis kinetics of -butyl acetate in the presence of a phase transfer catalyst [21]. Modeling of the system involved solving mass balance equations for coupled mass transfer and reactions for all of the species involved. Further recent applications of modified Lewis cells have focused on stripping-extraction kinetics [22-24], uncatalyzed hydrolysis [25,26], and partitioning kinetics [27]. [Pg.335]

This review has highlighted the wide range of techniques, which have been used to investigate reaction kinetics at liquid-liquid interfaces. While significant progress has been made in the last few years, in particular, many of the techniques currently in use have a number of drawbacks, and there is considerable scope for the introduction of further techniques which can match the criteria proposed in Section I. [Pg.356]

Touching on drawbacks of vapour-liquid method, we should note that among those there is a lack of control of the thickness of condensed liquid layer on detector surface which may result (for fairly thick liquid layers) in diffusion retardation of oxygen chemisorbtion. The diffusion... [Pg.209]

C, is one of the most critical parameters in TSP operation, and should be optimised for different samples, wherever possible. This is considered to be a considerable drawback in routine operation of unknown polymer/additive extracts. Too low a vaporiser temperature results in the solute and solvent spraying into the ionisation source in their liquid form, without formation of gas-phase ions. Too high a vaporiser temperature causes premature evaporation of the solute and solvent before the outlet of the capillary is reached. This causes an unstable, pulsing ion beam. As ion formation in TSP operation depends very critically on the extent of desolvation and the energy of the nebulised droplets, it is clear that an inappropriate vaporiser temperature will cause loss of sensitivity. [Pg.377]


See other pages where Liquid drawbacks is mentioned: [Pg.2826]    [Pg.333]    [Pg.1800]    [Pg.51]    [Pg.125]    [Pg.410]    [Pg.289]    [Pg.143]    [Pg.6]    [Pg.25]    [Pg.28]    [Pg.258]    [Pg.13]    [Pg.219]    [Pg.167]    [Pg.43]    [Pg.500]    [Pg.55]    [Pg.44]    [Pg.54]    [Pg.650]    [Pg.181]    [Pg.183]    [Pg.17]    [Pg.267]    [Pg.76]    [Pg.136]    [Pg.140]    [Pg.261]    [Pg.210]    [Pg.574]    [Pg.34]    [Pg.184]    [Pg.269]    [Pg.320]    [Pg.503]    [Pg.539]   