Liquid chromatography/mass spectrometry quality

TiUer, P.R. El FaUah, Z. Wilson, V. Huysman, J. Patel, D. Qualitiative assessment of leachables using data-dependent liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry. Rapid Commun. Mass Spectrom. 1997, 11, 1570-1574. [Pg.1101]

As FIA-MS and liquid chromatography mass spectrometry (LC-MS) become more pervasive in the analysis of compound libraries, open-access instrumentation is increasingly used in HTOS laboratories as well as in support of general medicinal chemistry. These open-access systems are most often used for reaction monitoring and optimization, and in some cases, for library quality control and synthesis product purification. [Pg.192]

See also Liquid Chromatography Chiral Liquid Chromatography-Mass Spectrometry. Pharmaceutical Analysis Drug Purity Determination. Quality Assurance Quality Control. [Pg.2729]

See a/so Clinical Analysis Sample Handling. Gas Chromatography Mass Spectrometry. Liquid Chromatography Liquid Chromatography-Mass Spectrometry. Mass Spectrometry Ionization Methods Ovenriew Atmospheric Pressure Ionization Techniques Time-of-Flight Selected Ion Monitoring Stable Isotope Ratio. Peptides. Proteins Traditional Methods of quence Determination. Quality Assurance Internal Standards. [Pg.2916]

High performance liquid chromatography (HPLC)-grade water (Honeywell Burdick and Jackson [Morristown, NJ] or other high quality liquid chromatography-mass spectrometry [LC/MS]-grade water). [Pg.5]

Smith, G.A., et ai. (2003) Liquid chromatography mass spectrometry (LC-MS) based method for the analysis of algai toxins. In Proceedings—Water Quality Technology Conference, 554-558... [Pg.471]

To conduct training courses for analysts of NRLs. A continuous series of laboratory workshops have been organized, (e.g., on immunoassays, high-performance liquid chromatography, and gas chromatography-mass spectrometry). A workshop held in 1991 at RIVM focused on -agonists whereas a workshop in March 1994 at RIVM focused on quality assurance (70). [Pg.376]

Tang, L., Fitch, W. L., Alexander, M. S., and Dolan, J. W. (2000). Expediting the method development and quality control of reversed-phase liquid chromatography electrospray ionization mass spectrometry for pharmaceutical analysis by using an LC/MS performance test mix. Anal. Chem. 72 5211-5218. [Pg.81]

A selective, sensitive, and rapid hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry was developed for the determination of donepezil in human plasma [32], Donepezil was twice extracted from human plasma using methyl-ferf-butyl ether at basic pH. The analytes were separated on an Atlantis HILIC Silica column with the mobile phase of acetonitrile ammonium formate (50 mM, pH 4.0) (85 15, v/v) and detected by tandem mass spectrometry in the selective reaction monitoring mode. The calibration curve was linear (r = 0.9994) over the concentration range of 0.10-50.0 ng/ ml and the lower limit of quantification was 0.1 ng/ml using 200 /d plasma sample. The CV and relative error for intra- and inter-assay at four quality control levels were 2.7% to 10.5% and —10.0% to 0.0%, respectively. There was no matrix effect for donepezil and cisapride. The present method was successfully applied to the pharmacokinetic study of donepezil after oral dose of donepezil hydrochloride (10 mg tablet) to male healthy volunteers. [Pg.141]


See other pages where Liquid chromatography/mass spectrometry quality is mentioned: [Pg.94]    [Pg.23]    [Pg.183]    [Pg.212]    [Pg.251]    [Pg.180]    [Pg.243]    [Pg.223]    [Pg.343]    [Pg.792]    [Pg.51]    [Pg.25]    [Pg.121]    [Pg.65]    [Pg.2136]    [Pg.26]    [Pg.126]    [Pg.167]    [Pg.720]    [Pg.199]    [Pg.75]    [Pg.213]    [Pg.44]    [Pg.935]    [Pg.210]    [Pg.211]    [Pg.71]    [Pg.39]    [Pg.230]    [Pg.231]    [Pg.23]    [Pg.55]    [Pg.61]    [Pg.766]    [Pg.117]    [Pg.139]    [Pg.85]    [Pg.360]    [Pg.466]    [Pg.633]   