Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Integrated Pulsed Amperometric Detection IPAD

Figure 4 Typical potential step sequence in (A) pulsed amperometric detection (PAD) and (B) integrated pulsed amperometric detection (IPAD) of peptides. Figure 4 Typical potential step sequence in (A) pulsed amperometric detection (PAD) and (B) integrated pulsed amperometric detection (IPAD) of peptides.
Figure 4.2 Usual potential waveforms employed in PAD [22, 32], (a) Triple-pulse PAD, (b) quadruple pulse PAD, and (c) triangular scan integrated pulsed amperometric detection (IPAD), fjg, detection potential oxidation potential for electrode conditioning E,, reduc-... Figure 4.2 Usual potential waveforms employed in PAD [22, 32], (a) Triple-pulse PAD, (b) quadruple pulse PAD, and (c) triangular scan integrated pulsed amperometric detection (IPAD), fjg, detection potential oxidation potential for electrode conditioning E,, reduc-...
Optimized Integrated Pulsed Amperometric Detection (IPAD) Waveform for Thiocompounds and Summary of Parameter Functions... [Pg.497]

HPCEC, High-performance cation exchange chromatography IPAD, Integrated pulse amperometric detection ISWD,... [Pg.100]

RP-HPLC, reversed-phase HPLC IPAD, integrated pulse amperometric detection Au, gold working electrode pSPE, pre-anodlzed screen printed electrode. [Pg.102]

Summary of the Analytical Figures of Merit Achievable with High-Performance Liquid Chromatography with Integrated Pulsed Amperometric Detection (HPLC-IPAD). These Data were Collected by Injecting Each Compound Separately with a Mobile Phase Chosen to Yield Similar k Values for Each Compound... [Pg.498]

FIGURE 10.17 Detection of thiocompounds in various samples by High-performance anion-exchange chromatography with integrated pulsed amperometric detection (HPLC-IPAD). Samples were (A) grapefruit juice, (B) watermelon, and (C) chicken liver. Condition Ci8, 1-mm SepStik column 99.6% 100 mM phosphate buffer (pH 3)/0.4% acetonitrile 65 p,L/min 0.5 p,L injection volume and detection, IPAD waveform in Table 10.3. Peaks a, GSH b, methionine and c, GSSG. (Reprinted from LaCourse, W.R. and Owens, G.S., Anal. Chim. Acta, 307, 301, 1995. With permission.)... [Pg.514]

It is used in IC systems when the amperometric process confers selectivity to the determination of the analytes. The operative modes employed in the amperometric techniques for detection in flow systems include those at (1) constant potential, where the current is measured in continuous mode, (2) at pulsed potential with sampling of the current at dehned periods of time (pulsed amperometry, PAD), or (3) at pulsed potential with integration of the current at defined periods of time (integrated pulsed amperometry, IPAD). Amperometric techniques are successfully employed for the determination of carbohydrates, catecholamines, phenols, cyanide, iodide, amines, etc., even if, for optimal detection, it is often required to change the mobile-phase conditions. This is the case of the detection of biogenic amines separated by cation-exchange in acidic eluent and detected by IPAD at the Au electrode after the post-column addition of a pH modiher (NaOH) [262]. [Pg.409]


See other pages where Integrated Pulsed Amperometric Detection IPAD is mentioned: [Pg.214]    [Pg.763]    [Pg.1219]    [Pg.378]    [Pg.496]    [Pg.82]    [Pg.482]    [Pg.214]    [Pg.763]    [Pg.1219]    [Pg.378]    [Pg.496]    [Pg.82]    [Pg.482]    [Pg.169]    [Pg.1297]    [Pg.95]    [Pg.446]    [Pg.513]   
See also in sourсe #XX -- [ Pg.93 ]

See also in sourсe #XX -- [ Pg.82 ]




SEARCH



Amperometric detection

Amperometric detection IPAD)

Detection integrated

Detection integrated pulsed

Detection pulsed

Integral detection

Pulsed amperometric detection

© 2024 chempedia.info