Transformers substation

Bus bars of a transformer substation must not be directly grounded. They must be connected with rails by at least two insulated cables. Metal sheathing of feeder and return current cables must only then be connected with the rails or bus bar if an increase in anodic corrosion on other buried installations is absolutely excluded. The insulation of all return cables must therefore be monitored regularly. [Pg.350]

The core of the network is the region of the rail network in which the branch line of two transformer substations or of any other branch line is less than 2 km distant in a direct line. All branch lines outside the core of the network are termed outlying lines. In a branched rail network, not only the stretches of line within a circle with a radius of 2 km from the most negative return current point of a transformer substation belong to the core of the network, but also connecting branch lines that are less than 2 km from each other [1]. The area of a network core can be simply determined on a track plan with the help of a circular template as in Fig. 15-1. [Pg.350]

The curves in Fig. 15-5 are greatly simplified and only apply to one instant of time. In practice there are always several trams with varying current draw on a stretch of track. Currents and potentials are then subjected to wide time-dependent variations. Without protective measures, the pipe/soil potentials are usually always more negative in the outer regions of a tramway system and more positive in the vicinity of the transformer substation. In a wide intermediate region, potential changes occur in both directions. The current entrance and exit areas can be deter-... [Pg.359]

Figure 15-8 shows synchronous recordings of the voltage between the pipeline and the rails, of the pipe/soil potential f/cu cuso4 drained current in the region of a tramway transformer substation with and without various protective measures. Figure 15-8a records values without protective measures. If the rails are negative with respect to the pipeline (f/R s > 0), the pipe/soil potential becomes more positive. Stray current exit exists. From time to time, however, < 0. [Pg.360]

With forced stray current drainage, the current is returned from the pipeline to the rails by means of a grid-fed rectifier. The transformer-rectifier is connected into the stray current return conductor, the negative pole is connected with the installation to be protected and the positive pole is connected to the rails or the negative side of the bus bar in the transformer substation. [Pg.361]

Provide information on the site layout including any other associated risks, including transformers, substations and water treatment facilities. Identify designated rendezvous points ... [Pg.229]

N Switch gear building Houses a transformer/substation. Block building of approximately 2,300 ft ... [Pg.111]


See other pages where Transformers substation is mentioned: [Pg.276]    [Pg.351]    [Pg.358]    [Pg.360]    [Pg.360]    [Pg.362]    [Pg.364]    [Pg.428]    [Pg.192]    [Pg.488]    [Pg.118]    [Pg.1838]    [Pg.1839]    [Pg.276]    [Pg.328]    [Pg.351]    [Pg.358]    [Pg.360]    [Pg.360]    [Pg.362]    [Pg.364]    [Pg.62]    [Pg.62]    [Pg.63]    [Pg.477]   