Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Indicators data analysis

Based on the bench-scale data, two coal-to-acetylene processes were taken to the pilot-plant level. These were the AVCO and Hbls arc-coal processes. The Avco process development centered on identifying fundamental process relationships (29). Preliminary data analysis was simplified by first combining two of three independent variables, power and gas flow, into a single enthalpy term. The variation of the important criteria, specific energy requirements (SER), concentration, and yield with enthalpy are indicated in Figure 12. As the plots show, minimum SER is achieved at an enthalpy of about 5300 kW/(m /s) (2.5 kW/cfm), whereas maximum acetylene concentrations and yield are obtained at about 7400 kW/(m /s) (3.5 kW/cfm). An operating enthalpy between these two values should, therefore, be optimum. Based on the results of this work and the need to demonstrate the process at... [Pg.391]

Measuring employee understanding of appropriate quality objectives is again a subjective process. Through the data analysis carried out to meet the requirements of clause 4.1.5 and 4.2.8 you will have produced metrics that indicate whether your quality objectives are being achieved. If they are being achieved you could either assume your employees understand the quality objectives or you could conclude that it doesn t matter. However, it does matter as the standard requires a measurement. Results alone are insufficient evidence. The results may have been achieved by pure chance and in six months time your performance may have declined significantly. The only way to test... [Pg.148]

Figure 5. Guanine-nucleotide-dependent receptor interconversion from LRG" to LR. Penneabilized cells (10 /mL) (no GTPyS 1 ml Mg " ) were allowed to bind FLPEP for 1 min. Data analysis begins with the addition of antibody to fluorescein (after 60 s, but not indicated). At 90 s (indicated), GTPyS is added to induce interconversion to the rapidly dissociating state. The guanine nucleotide concentrations are shown (saturated at 10" If). The solid lines are the fit to the onestep model shown in the inset, and the k for the fit is shown at the end of each solid line. Data... Figure 5. Guanine-nucleotide-dependent receptor interconversion from LRG" to LR. Penneabilized cells (10 /mL) (no GTPyS 1 ml Mg " ) were allowed to bind FLPEP for 1 min. Data analysis begins with the addition of antibody to fluorescein (after 60 s, but not indicated). At 90 s (indicated), GTPyS is added to induce interconversion to the rapidly dissociating state. The guanine nucleotide concentrations are shown (saturated at 10" If). The solid lines are the fit to the onestep model shown in the inset, and the k for the fit is shown at the end of each solid line. Data...
An experimental design Is sometimes taken to be a "test matrix" that Indicates the conditions associated with each test measurement. However, for statistical purposes the test matrix must reflect both the "experimental design" and the "data analysis" characteristics that are required to Identify separately the magnitudes of the different... [Pg.67]

In order to reduce unnecessary data queries, the statistics group should be consulted early in the clinical database development process to identify variables critical for data analysis. Optimally, the statistical analysis plan would already be written by the time of database development so that the queries could be designed based on the critical variables indicated in the analysis plan. However, at the database development stage, usually only the clinical protocol exists to guide the statistics and clinical data management departments in developing the query or data management plan. [Pg.21]

In this chapter, we focus on recent and emerging technologies that either are or soon will be applied commercially. Older technologies are discussed to provide historic perspective. Brief discussions of potential future technologies are provided to indicate current development directions. The chapter substantially extends an earlier publication (Davis et al., 1996a) and is divided into seven main sections beyond the introduction Data Analysis, Input Analysis, Input-Output Analysis, Data Interpretation, Symbolic-Symbolic Interpretation, Managing Scale and Scope of Large-Scale Process Operations, and Comprehensive Examples. [Pg.9]

Figures 8 and 9 show the first order kinetic plots for the isomerization and crosslinking reactions, respectively. In the data analysis the area of the isoimide peak was measured between consistent limits chosen to exclude any contribution from the 1775 cm imide band. These data were generated by measuring the area of the appropriate peak in a baseline corrected spectrum and ratioing this area to that of a reference peak (which was invarient during the experiment) in the same spectrum. This concentration indicative number was then ratioed to the concentration ratio observed on the initial scan. Plots of the log of the ratio of the concentration of the functionality at time "t" to the concentration of the functionality at t = 0 were then constructed. In order to insure that the trends in the data were not artifacts of this procedure or of the baseline correction routine, we also plotted the data in terms of peak intensity in absorbance units and observed the same trends but with more scatter in the data. Figures 8 and 9 show the first order kinetic plots for the isomerization and crosslinking reactions, respectively. In the data analysis the area of the isoimide peak was measured between consistent limits chosen to exclude any contribution from the 1775 cm imide band. These data were generated by measuring the area of the appropriate peak in a baseline corrected spectrum and ratioing this area to that of a reference peak (which was invarient during the experiment) in the same spectrum. This concentration indicative number was then ratioed to the concentration ratio observed on the initial scan. Plots of the log of the ratio of the concentration of the functionality at time "t" to the concentration of the functionality at t = 0 were then constructed. In order to insure that the trends in the data were not artifacts of this procedure or of the baseline correction routine, we also plotted the data in terms of peak intensity in absorbance units and observed the same trends but with more scatter in the data.
Using the conventional data analysis methods of PCA, DFA, and HCA, studies have indicated that the role of PyMS in microbiology may extend beyond... [Pg.329]

Table I is a list of physical properties of materials which were of special concern, along with target values felt to indicate useful levels in a particular application. From the beginning it was predicted that one of the biggest problems would be to balance Properties A and E, usually considered mutually exclusive. It was also assumed that Properties B and E were highly correlated. Statistically designed experiments and data analysis were chosen to determine most efficiently the formulations which would give the best combination of all the target properties. Table I is a list of physical properties of materials which were of special concern, along with target values felt to indicate useful levels in a particular application. From the beginning it was predicted that one of the biggest problems would be to balance Properties A and E, usually considered mutually exclusive. It was also assumed that Properties B and E were highly correlated. Statistically designed experiments and data analysis were chosen to determine most efficiently the formulations which would give the best combination of all the target properties.
Melroy and co-workers88 recently reported on the EXAFS spectrum of Pb underpotentially deposited on silver (111). In this case, no Pb/Ag scattering was observed and this was ascribed to the large Debye-Waller factor for the lead as well as to the presence of an incommensurate layer. However, data analysis as well as comparison of the edge region of spectra for the underpotentially deposited lead, lead foil, lead acetate, and lead oxide indicated the presence of oxygen from either water or acetate (from electrolyte) as a backscatterer. [Pg.302]

Most recently, we have been able to obtain the in situ surface EXAFS spectrum of a half-monolayer of underpotentially deposited copper on a bulk Pt(lll) single crystal pretreated with iodine. The spectrum shown in Fig. 23 is a bit noisy (due to limited number of scans) but at least five well-defined oscillations can be observed. Preliminary data analysis indicates that the copper adatoms sit on threefold hollow sites with copper neighbors at 2.80 0.03 A. This distance is very close to the Pt—Pt distance in the (111) direction and indicates the presence of a commensurate... [Pg.302]

Equations 12.4.22 and 12.4.24 indicate that the observed reaction order will differ from the intrinsic reaction order in the presence of intraparticle and/or external mass transfer limitations. To avoid drawing erroneous conclusions about intrinsic reaction kinetics, we must be careful to either eliminate these limitations by proper choice of experimental conditions or to properly take them into account in our data analysis. [Pg.479]

Figure 10.1. USAXS observation during straining of an SBS block copolymer. Right monitor Intensity maxima on an ellipse. Raw-data coordinate system (x,y) and radial cuts for data analysis are indicated. Middle Videotaping of sample. Left Stress-strain curve. Control booth of beamline BW4, HASYLAB, Hamburg... Figure 10.1. USAXS observation during straining of an SBS block copolymer. Right monitor Intensity maxima on an ellipse. Raw-data coordinate system (x,y) and radial cuts for data analysis are indicated. Middle Videotaping of sample. Left Stress-strain curve. Control booth of beamline BW4, HASYLAB, Hamburg...
An additional consideration for sample preparation is to ensure that the final sample solution is miscible with the HPLC eluent and will not alter or degrade the column.62 The total time needed for sample preparation may be longer than that required to conduct chromatographic separation and therefore becomes is the rate-determining step for the analysis.63 A survey cited by several authors indicated that on average chromatography separation accounts for about 15% of the total analysis time, sample preparation, about 60%, and data analysis and reporting, 25%.64 66... [Pg.350]

The more polar components have been characterised by FTICR—MS and HPLC-ESI-MS, and include excess PEG [CH30(E0)nH and HO(EO) Hl starting materials, confirmation of which was obtained by comparison with commercial standards [29]. ESI—MS, FTICR—MS and H NMR data analysis also indicated the presence of the Si—O—C byproduct 3, abbreviated to MDOH-0-(E0)ra-CH2CH=CH2, shown in Fig. 2.8.7. The formation of 3 can occur through side reactions of the... [Pg.247]

As the title Practical Data Analysis in Chemistry indicates, there are different facets to the book ... [Pg.1]


See other pages where Indicators data analysis is mentioned: [Pg.1977]    [Pg.285]    [Pg.128]    [Pg.16]    [Pg.213]    [Pg.189]    [Pg.348]    [Pg.65]    [Pg.143]    [Pg.111]    [Pg.210]    [Pg.448]    [Pg.46]    [Pg.95]    [Pg.262]    [Pg.10]    [Pg.182]    [Pg.44]    [Pg.343]    [Pg.545]    [Pg.135]    [Pg.421]    [Pg.468]    [Pg.205]    [Pg.254]    [Pg.137]    [Pg.146]    [Pg.100]    [Pg.132]    [Pg.186]    [Pg.22]    [Pg.66]    [Pg.97]    [Pg.110]    [Pg.293]   
See also in sourсe #XX -- [ Pg.590 , Pg.591 , Pg.592 , Pg.593 ]




SEARCH



Indicators analysis

© 2024 chempedia.info