Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Indicator contaminants

Testing for the presence of permeated chemical contaminants requires that pieces (in the case of contaminated soil this would be typically those that visually indicate contamination) of the protective garments be sent to a laboratory for analysis. [Pg.157]

During the separation itself some trouble can occur concerning the back pressure. An increasing back pressure indicates contamination of the column and thus should be monitored. If this happens or if a visible contamination of the sorbent is noticed, a regeneration of the column is necessary. However, if the back pressure rises very rapidly the column may be clogged by denatured proteins. As a first attempt, the frits should be replaced by new ones, trying the top adapter first. [Pg.246]

Apart from the observation that the concentrations are generally higher than those measured previously, which indicates contamination during conditioning and manipulation, and the necessity of frequently renewing seawater for equilibration purposes, it can be seen that there are no changes in the metal concentrations for three months for lead and copper, or for five months for cadmium. Also, after five months storage, some loss of lead and... [Pg.51]

The process flow sheet was first tested for direct leaching of steel mill flue dust and production of zinc metal by electrowinning. The tests were performed in a continuously operating pilot plant, producing 10-20 kg/day zinc metal. The same pilot plant was then used for treating copper/zinc-rich brass mill flue dust in a closed loop operation, recycling all the zinc solvent extraction raffinate to the copper circuit leach section. In the zinc circuit leach section, only the amount of zinc rich dust necessary for neutralization of the copper solvent extraction raffinate was used. The results obtained from the pilot plant tests indicated contamination problems within the solvent extraction loops. The estimation of economic data showed a weak return on the assets compared with the alkali route, and sensitivity toward the raw material price. [Pg.620]

Chemical Composition of NPL. When tested as in 4.3 1, the result shall match the typical IR curve presented in Fig Etl6. The presence of additional absorption peaks shall require rejection if the indicative contamination is judged excessive by the analyst... [Pg.146]

A melting point in the lower part of this range generally indicates contamination with / -tolylsulfonylmethylamide, which may be removed as described in Note 6 however, this purification is not necessary since the presence of this amide does not interfere in the preparation of diazomethane. [Pg.99]

Note Following reconstitution, reagent should be used immediately. Any reagent remaining after reconstitution is stable at 2 to 8°C for 24 hours or for up to 1 month at -20°C or below. Reconstituted reagent can be frozen-thawed only once. Reconstituted reagent should be slightly opalescent. Yellow color indicates contamination or denaturation. Label vial with initials, date reconstituted, and expiration. [Pg.950]

Note 3 Reconstituted reagent should be slightly opalescent. Yellow color indicates contamination or denaturation. [Pg.961]

Values higher than the index values indicating contamination in the KLOKE list [HEIN and SCHWEDT, 1993] cannot be found. [Pg.354]

This type of sampling may also rely on immediate observations. For example, judgmental sampling is appropriate for investigating hot spots, such as stains, spills, or discoloration, which may indicate contamination. The knowledge of the operational modes or past practices at the project site may also serve as a basis for judgmental sampling. [Pg.65]

It should not be assumed that anomalous concentrations necessarily indicate contamination. Bolviken and Lag (1977) have described areas in Norway where the absence of vegetation is due to the toxic effects of high concentrations of metals in soils as a result of weathering of sulphide ores close to the surface. This is a natural process having nothing to do with contamination. [Pg.18]

The chromosomes constitution of cells, or cell hybrids, is an important criterion for monitoring the nature of cells in culture. It may help to indicate contamination of the cells of one species with those of another and enables the elucidation of the chromosomal location of various genetic markers. In vitro, however, cells often change their chromosome constitution and most cell lines no longer have the diploid number of chromosomes. Rather they are aneuploid and may have a wide range of chromosomes per cell (see 2.2)... [Pg.136]

The presence of stable frodi when the sample is shaken (with water if necessary) may indicate contamination with soap or detergents. Acidify the sample, shake again, and if froth still forms, a detergent rather than soap is present. Although of low toxicity, soap, detergents, and cleaning powders are frequently die cause of complaints of poisoning. [Pg.49]

Anade-Ckusenrearrai ement. Satisfactory A4-cholestene-3j -ol, m.p. 130.5-131° (from ethanol), can be prepared by the procedure of Burgstahler and Nordin a lower melting point indicates contamination with some of the 5oi-hydroxy isomer. A 50-ml. [Pg.166]

In the report by Santos et al. (1995) Po and °Pb concentrations in urine, hair and skin smear samples from individuals using phosphated fertilizers have been compared with a control group of occupationally unexposed individuals. Urine and hair samples of the test group showed slightly higher concentrations of "Po and °Pb than those observed for the control group. These concentrations remained, however, lower than those for uranium mine workers. Skin smear values indicated contamination by direct contact with dust from fertilizers and this may contribute to skin cancer induction in this risk population. [Pg.49]

The most common problem associated with analytical columns is column deterioration. Deterioration may appear as poor peak shapes, split peaks, shoulders, loss of resolution, decreased retention times, and high backpressure. These symptoms indicate contaminants that have accumulated on the frit or column inlet, or there are voids, channels, or a depression in the packing bed. Deterioration is more evident in higher efficiency columns. For example, a column with 3-pm packing is more susceptible to plugging than one with 5- or 10-pm packing. Proper column protection and sample preparation are essential to prolong a column s life and obtain its best performance. [Pg.1664]

A low boiling, silicon-containing fraction is also collected below 37°C (28 mm). The presence of a singlet at 0.10 ppm in the NMR of the product indicates contamination by this low boiling fraction. Small amounts of this impurity do not seem to interefere in subsequent reactions of the 1-bromo-l-ethoxycyclopropane. [Pg.214]

Doubly prototropic furans are known. The simplest (125) is unstable but can be obtained in 15% yield by treating tetra(bromomethyl)ethene with sodium hydroxide. The product lacks an IR band at 1725 cm-1 that had been noted in a different preparation, now thought to indicate contamination by acetic acid.242 Another such compound has structure 126, remarkable because the butadiene chromophores react strongly across the ring.243 No special sensitivity is reported, and aromatization would of course be prevented because of the inordinate strain imposed according to Bredt s rule. The plant Limlera obtusiloba Blume elaborates as a main component of its leaves a furan derivative known as obtusilactone244 structure 127 possesses... [Pg.300]


See other pages where Indicator contaminants is mentioned: [Pg.18]    [Pg.5]    [Pg.379]    [Pg.878]    [Pg.70]    [Pg.48]    [Pg.81]    [Pg.362]    [Pg.161]    [Pg.52]    [Pg.229]    [Pg.28]    [Pg.278]    [Pg.151]    [Pg.109]    [Pg.327]    [Pg.226]    [Pg.179]    [Pg.30]    [Pg.265]    [Pg.361]    [Pg.985]    [Pg.659]    [Pg.233]    [Pg.56]    [Pg.1765]    [Pg.155]   


SEARCH



Contamination, bacterial, Indicator

Ecosystem Responses to Mercury Contamination: Indicators of Change

Indicator contaminants case study examples

© 2024 chempedia.info