Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Storage hazard

Inventories, See Chemicals Major hazards Storage Iron, 30... [Pg.603]

A lab method of prepn is described in Ref 6. Its toxicology, fire hazard, storage and handling are discussed in Ref 7. It was claimed (Ref 3) that the ignition sensitivity life of igniter compds contg cuprous acery-lide(or other metallic acetylides) is improved by the addition of small amounts of abietic acid... [Pg.3]

Toxicity, fire expln hazards, storage handling and shipping regulations are discussed in Ref 9... [Pg.71]

In order to minimize hazards, storage tanks for inflammable or toxic materials may be buried. Then they are provided with an overburden of 1.3 times the weight of water that the tank could hold in order to prevent floating after heavy rainfalls. [Pg.621]

Toxicity, fire 8c e spin hazards, storage 8c handling and shipping leguladons are diacussed in Ref 9... [Pg.71]

This database contains the complete text of over 130,000 Material Safety Data Sheets compiled by the Canadian Center for Occupational Health and Safety (CCOHS). This information was gathered from over 500 manufacturers and suppliers in the United States and Canada. Each record covers one chemical substance and provides trade and supplier name, description, chemical/physical properties, reactivity, health hazards, storage and disposal, personal protection, cleanup and disposal, and emergency first aid (CCINFOLINE, STN available on CD from CCOHS). [Pg.1434]

One Way Fire Wall Commonly used to subdivide a lighter hazard storage area from a higher hazard area. Designed to withstand a fire on one side only, and tied to structural members on the low hazard side. Clearance maintained between the one-way wall and steel on the high hazard side to prevent damage to the wall due to steel expansion. Two one-way fire walls installed back to back. Structural steel exposed on one side of each wall, and a specified minimum clearance provided between the two walls. [Pg.91]

Next to the legislation on OELs and BATs, the requirements of the Ordinance on Hazardous Substances apply as well as various other regulations at national level dealing with flammable liquids, water pollution, air pollution,major hazards,storage and transport, protective equipment and ventilation. [Pg.206]

Environmental Not thought to present an immediate ecological hazard Storage 1 yr shelf life when stored in a sealed container in cool, dark area 5-50 C do not allow to freeze Joncryl 56 [S.C. Johnson Polymer]... [Pg.447]

Precaution Airborne dust constitutes an explosion hazard Storage Store in cool, dry place away from direct sunlight, heat, spark, or flame... [Pg.888]

Engineering guidelines produced by Factory Mutual (FM) to help reduce the risk of property loss due to fire, weather, and/or electrical or mechanical equipment failure. They are based on input from loss experience, research results, consensus standards committees, equipment manufacturers, and other interested participants. The subjects covered include construction, sprinklers, water supply, extinguishing equipment, electrical equipment, boilers and industrial heating equipment, hazards, storage, miscellaneous, human factors, systems instrumentation and control, pressure vessels, mechanical, welding, and boiler and machinery. They may also be referred to as FM Global Property Loss Prevention Data Sheets. See also Factory Mutual (FM). [Pg.135]

Areas within a facility which use or store less than the exempt amounts of HPMs may be considered control areas and must be constructed with not less than one-hour partitions. The control area is a space within an occupancy which does not have to be considered a specific hazardous storage occupancy such as H-1, H-2, H-3 or H-7. There may be up to four individual control areas within a building however, the aggregate quantity of HPMs in a fab area (including control rooms) may not exceed the maximum amounts in UFC Table 5103-A (in 1994 UBC, pg. 1-160). [Pg.432]

The determination of hazards for LNG begins with an understanding of the properties of the fuel. The following characteristics are important to identifying LNG hazards storage parameters, tendency to form combustible mixture, ignition and explosion characteristics, means of controlling combustion and environmental effects. [Pg.1556]

However, when the rate of change of thermal overfill d(TO)av/dt is positive over a period of time, then a hazardous storage situation is building up part of the heat inflow is being stored in the hquid and is not being absorbed by evaporation and removed from the hquid. It should be noted that d(TO)av/dt is positive when the atmospheric pressure (and the reference pressure Po) is fading. [Pg.20]


See other pages where Storage hazard is mentioned: [Pg.86]    [Pg.277]    [Pg.1086]    [Pg.309]    [Pg.72]    [Pg.1017]    [Pg.2767]    [Pg.2827]    [Pg.441]    [Pg.27]    [Pg.141]    [Pg.288]    [Pg.694]    [Pg.95]    [Pg.201]    [Pg.223]    [Pg.42]    [Pg.264]   
See also in sourсe #XX -- [ Pg.33 ]




SEARCH



Hazardous storage

© 2024 chempedia.info