FTICR cyclotron resonance

Other types of mass spectrometer may use point, array, or both types of collector. The time-of-flight (TOF) instrument uses a special multichannel plate collector an ion trap can record ion arrivals either sequentially in time or all at once a Fourier-transform ion cyclotron resonance (FTICR) instrument can record ion arrivals in either time or frequency domains which are interconvertible (by the Fourier-transform technique). [Pg.201]

An added consideration is that the TOF instruments are easily and quickly calibrated. As the mass range increases again (m/z 5,000-50,000), magnetic-sector instruments (with added electric sector) and ion cyclotron resonance instruments are very effective, but their prices tend to match the increases in resolving powers. At the top end of these ranges, masses of several million have been analyzed by using Fourier-transform ion cyclotron resonance (FTICR) instruments, but such measurements tend to be isolated rather than targets that can be achieved in everyday use. [Pg.281]

FTICR. Fourier-transform ion cyclotron resonance GC/IRMS. gas chromatography isotope ratio mass spectrometry... [Pg.445]

To check the identity and purity of the products obtained in the above reactions it is not sufficient to analyze for the sulfur content since a mixture may incidentally have the same S content. Either X-ray diffraction on single crystals or Raman spectra of powder-like or crystalline samples will help to identify the anion(s) present in the product. However, the most convincing information comes from laser desorption Fourier transform ion cyclotron resonance (FTICR) mass spectra in the negative ion mode (LD mass spectra). It has been demonstrated that pure samples of K2S3 and K2S5 show peaks originating from S radical anions which are of the same size as the dianions in the particular sample no fragment ions of this type were observed [28]. [Pg.132]

Resolution does not affect the accuracy of the individual accurate mass measurements when no separation problem exists. When performing accurate mass measurements on a given component in a mixture, it may be necessary to raise the resolution of the mass spectrometer wherever possible. Atomic composition mass spectrometry (AC-MS) is a powerful technique for chemical structure identification or confirmation, which requires double-focusing magnetic, Fourier-transform ion-cyclotron resonance (FTICR) or else ToF-MS spectrometers, and use of a suitable reference material. The most common reference materials for accurate mass measurements are perfluorokerosene (PFK), perfluorotetrabutylamine (PFTBA) and decafluorotriph-enylphosphine (DFTPP). One of the difficulties of high-mass MS is the lack of suitable calibration standards. Reference inlets to the ion source facilitate exact mass measurement. When appropriately calibrated, ToF mass... [Pg.356]

B magnetic sector E = electric sector Q = quadrupole mass filter ToF = time-of-flight mass spectrometer IT = ion trap FTICR = Fourier-transform ion-cyclotron resonance. [Pg.386]

Currently PCR and mass spectrometry are performed by two separate instruments. However, there is no reason why PCR followed by simple automated cleanup and mass spectrometry cannot be incorporated into a single integrated instrument. Essentially every configuration of the modern ESI mass spectrometer has been used successfully for the analysis of PCR products, from the highest to the lowest resolution involving. Fourier transform ion cyclotron resonance (FTICR), triple quadrupole, quadrupole-time of flight (Q-TOF), and ion trap.22-24 MS discriminates between two structurally related PCR products by MW difference. Mass accuracy is needed to differentiate the... [Pg.28]

Different mass analysers can be combined with the electrospray ionization source to effect analysis. These include magnetic sector analysers, quadrupole filter (Q), quadrupole ion trap (QIT), time of flight (TOF), and more recently the Fourrier transform ion cyclotron resonance (FTICR) mass analysers. Tandem mass spectrometry can also be effected by combining one or more mass analysers in tandem, as in a triple quadrupole or a QTOF. The first analyzer is usually used as a mass filter to select parent ions that can be fragmented and analyzed by subsequent analysers. [Pg.237]

Mass analyzers interrogate and resolve ions produced by an ion source based on their m/z ratios. Several types of mass analyzers are utilized for proteomic analysis including time-of-flight (TOF) quadrupoles, ion traps, and Fourier transform ion cyclotron resonance (FTICR). Mass analyzers may be assembled in hybrid configurations. MS instruments such as quadrupole TOF and quadra-pole ion trap-FTICR facilitate diversified applications and achieved great success. [Pg.381]

DGE a AC AMS APCI API AP-MALDI APPI ASAP BIRD c CAD CE CF CF-FAB Cl CID cw CZE Da DAPCI DART DC DE DESI DIOS DTIMS EC ECD El ELDI EM ESI ETD eV f FAB FAIMS FD FI FT FTICR two-dimensional gel electrophoresis atto, 10 18 alternating current accelerator mass spectrometry atmospheric pressure chemical ionization atmospheric pressure ionization atmospheric pressure matrix-assisted laser desorption/ionization atmospheric pressure photoionization atmospheric-pressure solids analysis probe blackbody infrared radiative dissociation centi, 10-2 collision-activated dissociation capillary electrophoresis continuous flow continuous flow fast atom bombardment chemical ionization collision-induced dissociation continuous wave capillary zone electrophoresis dalton desorption atmospheric pressure chemical ionization direct analysis in real time direct current delayed extraction desorption electrospray ionization desorption/ionization on silicon drift tube ion mobility spectrometry electrochromatography electron capture dissociation electron ionization electrospray-assisted laser desorption/ionization electron multiplier electrospray ionization electron transfer dissociation electron volt femto, 1CT15 fast atom bombardment field asymmetric waveform ion mobility spectrometry field desorption field ionization Fourier transform Fourier transform ion cyclotron resonance... [Pg.11]

Ion detection is carried out using image current detection with subsequent Fourier transform of the time-domain signal in the same way as for the Fourier transform ion cyclotron resonance (FTICR) analyzer (see Section 2.2.6). Because frequency can be measured very precisely, high m/z separation can be attained. Here, the axial frequency is measured, since it is independent to the first order on energy and spatial spread of the ions. Since the orbitrap, contrary to the other mass analyzers described, is a recent invention, not many variations of the instrument exist. Apart from Thermo Fischer Scientific s commercial instrument, there is the earlier setup described in References 245 to 247. [Pg.57]

Principle. The principle of the ion cyclotron resonance was developed in the early 1930s by Lawrence and coworkers [252, 253]. The utilization of the ion cyclotron resonance (ICR) technique for mass spectrometry was introduced around 1950 by Sommer et al. [254, 255], and combination with the Fourier transform (FT) technique was developed by Comisarow and Marshall in 1974 [256], Coupling of external sources to an FTICR analyzer was first done in 1985 [257, 258],... [Pg.58]

Figure 2.19. Schematic of a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer (a) and a cylindrical cell (b). Reprinted from A. Westman-Brinkmalm and G. Brinkmalm (2002). In Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research, J. Silberring and R. Ekman (eds.) New York John Wiley Sons, 47-105. With... Figure 2.19. Schematic of a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer (a) and a cylindrical cell (b). Reprinted from A. Westman-Brinkmalm and G. Brinkmalm (2002). In Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research, J. Silberring and R. Ekman (eds.) New York John Wiley Sons, 47-105. With...
Fourier transform ion cyclotron resonance (FTICR) analyzer is excellent for MSn measurements (see Section 2.2.6), perhaps even more so, since the ions remain in the cell after detection. In principle one injection of ions is enough for a whole MSn sequence, including acquisition of a mass spectrum of each step. [Pg.96]

In addition to the diversity of ionisation techniques available, mass spectrometers offer a selection of mass analyser configurations. Of note are single (MS) and triple quadrupole (MS—MS) instruments, ion trap analysers (MS)n, time-of-flight (ToF) analysers, sector field analysers, and Fourier transform-ion cyclotron resonance (FTICR) instruments. [Pg.147]

Laser desorption (LD) Fourier transform ion cyclotron resonance MS (FTICR-MS) in the positive mode was applied for the analysis of... [Pg.263]

Octadecyl sulfate sodium salt (Ci8H37-0-S03 Na+) was examined by laser desorption (LD) Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) in the negative mode resulting in [M - H] ions. Little fragmentation was observed under these conditions [28]. [Pg.342]

The development of mass spectrometric techniques, such as fast atom bombardment mass spectrometry (FAB-MS), ° ° Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS), ° and tandem mass spectrometry (MS"), ° allowed enantiodiscrimination of chiral ion-dipole complexes the gas phase. These techniques and others will be illustrated in detail in the next Section 3. [Pg.155]

In the present review, a new variation on an existing experimental method will be used to show how accurate unimolecular dissociation rate constants can be derived for thermal systems. For example, thermal bimolecular reactions are amenable to study by use of several, now well-known, techniques such as (Fourier transform) ion cyclotron resonance spectrometry (FTICR), flowing afterglow (FA), and high-pressure mass spectrometry (HPMS). In systems where a bimolecular reaction leads to products other than a simple association adduct, the bimolecular reaction can always be thought of as containing a unimolecular... [Pg.43]

The instruments used for the experimental work detailed in this review are several high-pressure mass spectrometers (HPMS) and a Fourier transform ion cyclotron resonance spectrometer (FTICR). Each of the instruments was constructed, to a considerable degree, in-house at the University of Waterloo, and each contains features unique to its type of apparatus. The instruments in general and the unique features of the Waterloo apparatus in particular are described below. [Pg.44]

More recently, Audier and McMahon have shown that the unimolecular dissociation spectrum of transient ions can be directly obtained from a simple manipulation of a series of FTICR spectra. The data arising from this approach very closely resemble those obtained from metastable dissociations in conventional sector spectrometers (MIKES), and it has been consequently dubbed metastable ion cyclotron resonance (MICR) spectrometry. Very briefly, the method functions as follows ... [Pg.65]

The same group studied the lithium cation basicities of a series of compounds of the general formula R R R PO, i.e. phosphine oxides, phosphinates, phosphonates and phosphates, by using Fourier Transform Ion Cyclotron Resonance (FTTCR) mass spectrometry. A summary of their results is shown in Figure 4. The effect of methyl substitution on LCA as well as the correlation between LCA and PA was also investigated by Taft, Yanez and coworkers on a series of methyldiazoles with an FTICR mass spectrometer. They showed that methyl substituent effects on Li binding energies are practically additive. [Pg.211]

General Methods. The instrument that will be used to execute the gas-phase experimental portion of the proposed research is a Finnigan 2001 dual-cell Fourier transform ion cyclotron resonance mass spectrometer (FTMS or FTICR), equipped with both electron impact (FI) and electrospray ionization (FSl). FTMS is a high-resolution, high-sensitivity technique that allows the entrapment and detection of gas-phase species. Gas-phase ions are trapped in a magnetic field, much like a reactant sits in a flask in solution. The instrument is a mass spectrometer therefore, we will often refer to the mass-to-charge (m/z) ratio of ions, which is the method we use to identify species. (M-l) or (M-H) refers to a molecule M that has been deprotonated for example, HjO has an (M-f) ion of m/z 17 (HO ). [Pg.466]

In 1974, Comarisov and Marshall60 developed Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). This technique allows mass spectrometric measurements at ultrahigh mass resolution (R = 100000-1000000), which is higher than that of any other type of mass spectrometer and has the highest mass accuracy at attomole detection limits. FTICR-MS is applied today together with soft ionization techniques, such as nano ESI (electrospray ionization) or MALDI (matrix assisted laser/desorption ionization) sources. [Pg.21]


See other pages where FTICR cyclotron resonance is mentioned: [Pg.189]    [Pg.542]    [Pg.395]    [Pg.16]    [Pg.38]    [Pg.38]    [Pg.269]    [Pg.244]    [Pg.665]    [Pg.547]    [Pg.461]    [Pg.122]    [Pg.42]    [Pg.88]    [Pg.431]   