Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fourier transform infrared spectroscopy surface

Transmission Fourier Transform Infrared Spectroscopy. The most straightforward method for the acquisition of in spectra of surface layers is standard transmission spectroscopy (35,36). This approach can only be used for samples which are partially in transparent or which can be diluted with an in transparent medium such as KBr and pressed into a transmissive pellet. The extent to which the in spectral region (typically ca 600 4000 cm ) is available for study depends on the in absorption characteristics of the soHd support material. Transmission ftir spectroscopy is most often used to study surface species on metal oxides. These soHds leave reasonably large spectral windows within which the spectral behavior of the surface species can be viewed. [Pg.285]

Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy. Attenuated total redectance (atr) ftir spectroscopy is based on the principle of total internal redection (40). Methods based on internal redection in the uv and visible regions of the spectmm are also common in addition to those in the ir region. The implementation of internal redection in the ir region of the spectmm provides a means of obtaining ir spectra of surfaces or interfaces, thus providing moleculady-specific vibrational information. [Pg.286]

At present, most workers hold a more realistic view of the promises and difficulties of work in electrocatalysis. Starting in the 1980s, new lines of research into the state of catalyst surfaces and into the adsorption of reactants and foreign species on these surfaces have been developed. Techniques have been developed that can be used for studies at the atomic and molecular level. These techniques include the tunneling microscope, versions of Fourier transform infrared spectroscopy and of photoelectron spectroscopy, differential electrochemical mass spectroscopy, and others. The broad application of these techniques has considerably improved our understanding of the mechanism of catalytic effects in electrochemical reactions. [Pg.553]

There are several other techniques Uke the fluorescent dye displacement assays, footprinting, Fourier transform infrared spectroscopy. X-ray crystallography, electron microscopy, confocal microscopy, atomic force microscopy, surface plasmon resonance etc used for hgand-DNA interactions that are not discussed here. [Pg.173]

Gaboury, S. R. Urban, M. W. Analysis of Gas-Plasma-Modified Poly(Dimethylsiloxane) Elastomer Surfaces. Attenuated-Total-Reflectance-Fourier Transform Infrared Spectroscopy. In Structure-Property Relations in Polymers Urban, M. W., Graver, C. D., Eds. Advances in Chemistry Series 236 American Chemical Society Washington, DC, 1993 pp 777-790. [Pg.698]

Fourier transformed infrared spectroscopy(FTIR) Parkin-aim 6X2000 Surface chemis y, adsorbed species, reaction mechanism Trained Free... [Pg.354]

The 11 nm-sized Ti02 were crystallized using either hydrothermal or thermal methods from 100 nm, amorphous gel spheres. The Ti02 crystal and agglomerate sizes were determined by X-ray diffraction (Philip 1080) and transmission electron microscopy (JEOL JEM 2010), respectively. The surface area and chemistry of the nanostructured Ti02 were analyzed by nitrogen physisorption (Coulter SA 3100) and Fourier transform infrared spectroscopy (FTIR, Perkin-Elmer GX 2000). Metal catalyst was deposited by incipient... [Pg.375]

Zeitner, W. A., E. C. Yost, M. L. Machesky, M. I. Tejedor-Tejedor, and M. A. Anderson (1986), "Characterization of Anion Binding on Goethite Using Titration Calorimetry and Cylindrical Internal Reflec-tion-Fourier Transform Infrared Spectroscopy", in J. A. Davis and K. F. Hayes, Eds., Geochemical Processes at Mineral Surfaces, Am. Chem. Soc., Washington, 142-161. [Pg.418]

Spectroscopic techniques may provide the least ambiguous methods for verification of actual sorption mechanisms. Zeltner et al. (Chapter 8) have applied FTIR (Fourier Transform Infrared) spectroscopy and microcalorimetric titrations in a study of the adsorption of salicylic acid by goethite these techniques provide new information on the structure of organic acid complexes formed at the goethite-water interface. Ambe et al. (Chapter 19) present the results of an emission Mossbauer spectroscopic study of sorbed Co(II) and Sb(V). Although Mossbauer spectroscopy can only be used for a few chemical elements, the technique provides detailed information about the molecular bonding of sorbed species and may be used to differentiate between adsorption and surface precipitation. [Pg.7]

Most earlier papers dealt with the mercury electrode because of its unique and convenient features, such as surface cleanness, smoothness, isotropic surface properties, and wide range of ideal polarizability. These properties are gener y uncharacteristic of solid metal electrodes, so the results of the sohd met electrolyte interface studies are not as explicit as they are for mercury and are often more controversial. This has been shown by Bockris and Jeng, who studied adsorption of 19 different organic compounds on polycrystaUine platinum electrodes in 0.0 IM HCl solution using a radiotracer method, eUipsometry, and Fourier Transform Infrared Spectroscopy. The authors have determined and discussed adsorption isotherms and the kinetics of adsorption of the studied compounds. Their results were later critically reviewed by Wieckowski. ... [Pg.16]

Fourier transform Infrared spectroscopy has been shown to be an excellent tool for surface and Interface studies (.2), In this paper, the application of reflection/absorption Fourier transform Infrared spectroscopy (FTIR-RA) for studying the degradation of amine-cured epoxy and polybutadiene coatings on cold-rolled steel after exposure to a warm, humid environment is reported. [Pg.101]

Probing Metalloproteins Electronic absorption spectroscopy of copper proteins, 226, 1 electronic absorption spectroscopy of nonheme iron proteins, 226, 33 cobalt as probe and label of proteins, 226, 52 biochemical and spectroscopic probes of mercury(ii) coordination environments in proteins, 226, 71 low-temperature optical spectroscopy metalloprotein structure and dynamics, 226, 97 nanosecond transient absorption spectroscopy, 226, 119 nanosecond time-resolved absorption and polarization dichroism spectroscopies, 226, 147 real-time spectroscopic techniques for probing conformational dynamics of heme proteins, 226, 177 variable-temperature magnetic circular dichroism, 226, 199 linear dichroism, 226, 232 infrared spectroscopy, 226, 259 Fourier transform infrared spectroscopy, 226, 289 infrared circular dichroism, 226, 306 Raman and resonance Raman spectroscopy, 226, 319 protein structure from ultraviolet resonance Raman spectroscopy, 226, 374 single-crystal micro-Raman spectroscopy, 226, 397 nanosecond time-resolved resonance Raman spectroscopy, 226, 409 techniques for obtaining resonance Raman spectra of metalloproteins, 226, 431 Raman optical activity, 226, 470 surface-enhanced resonance Raman scattering, 226, 482 luminescence... [Pg.457]

V(IV) complexes that are coordinated by six sulfur donor atoms are also known. For example, [AsPh4]2[V(mnt)3] (mnt = maleonitriledithiolate) displays three redox features on cyclic voltammetry, which correspond to the reversible V(V/IV), V(IV/III), and quasireversible V(III/II) couples at 0.17, —0.87, and —2.12 V versus Cp2Fe/CH2Cl2 [55]. The surface normalized incident Fourier transform infrared spectroscopy (SNIFTIRS) spectroelectro-chemical technique was used to determine that the extent of n bonding of the mnt ligand increases as the metal s oxidation state is lowered through examination of the v(CN) frequencies in the various oxidation states. This technique was particularly effective in the determination of the spectral features ofthe short-lived V(II) species. [Pg.368]

Hamelin [47] has shown that specific adsorption of OH ions increases in the following order Au(lll) < Au(lOO) < Au(311). Chen and Lipkowski [48] have applied chronocoulometry and subtractively normalized interfacial Fourier transform infrared spectroscopy to study adsorption of hydroxide ions on Au(lll) electrode. This process proceeded in three steps. Bonding of OH with gold atoms that is quite polar at negatively charged surface becomes less polar at positively... [Pg.847]

FTIR Spectroscopy and Mechanisms on Electrode. The basis of Fourier transform infrared spectroscopy was described in Section 6.2.6. One of the more difficult aspects of detecting the mechanism of electrode reactions is that of knowing the nature of the intermediate radicals on the electrode surface. Infrared spectroscopy measures chemical bonds, so it is an ideal method for detecting which bonds are present and hence which intermediate radicals are taking part in a surface reaction at a given potential, etc. [Pg.430]


See other pages where Fourier transform infrared spectroscopy surface is mentioned: [Pg.297]    [Pg.224]    [Pg.555]    [Pg.353]    [Pg.341]    [Pg.30]    [Pg.236]    [Pg.551]    [Pg.134]    [Pg.218]    [Pg.75]    [Pg.16]    [Pg.305]    [Pg.323]    [Pg.338]    [Pg.340]    [Pg.89]    [Pg.36]    [Pg.223]    [Pg.23]    [Pg.81]    [Pg.176]    [Pg.80]    [Pg.264]    [Pg.118]    [Pg.596]    [Pg.860]    [Pg.689]    [Pg.10]    [Pg.104]    [Pg.177]   
See also in sourсe #XX -- [ Pg.168 , Pg.169 , Pg.170 , Pg.171 ]




SEARCH



Fourier spectroscopy

Fourier transform infrared

Fourier transform infrared surface

Fourier transform spectroscopy

Fourier transform spectroscopy infrared

Infrared spectroscopy surfaces

Infrared spectroscopy, fourier

Surface spectroscopy

Transformed infrared spectroscopy

© 2024 chempedia.info