Flow control measurement

In many industrial control problems, notably those involving temperature, pressure, and flow control, measurements of the controlled variable are available, and the manipulated variable is adjusted via a control valve. In feedback control, corrective action is taken regardless of the source of the disturbance. Its chief drawback is that no corrective action is taken until after the controlled variable deviates from the set point. Feedback control may also result in undesirable oscillations in the controlled variable if the controller is not tuned properly, that is, if the adjustable controller parameters are not set at appropriate values. The tuning of the controller can be aided by using a mathematical model of the dynamic process, although an experienced control engineer can use trial-and-error tuning to achieve satisfactory performance in many cases. Next, we discuss the two types of controllers used in most commercial applications. [Pg.1973]

Control Systems. Control systems are used to regulate the addition of Hquid waste feed, auxiHary fuel, and combustion air flows to the incinerator furnace. In addition, scmbber operation is automated to help ensure meeting emission limits. Flows are measured using differential pressure... [Pg.54]

Some toll processes lend themselves to test runs in the pre-startup phase. Actual materials for the toll may be used in the test or substitute materials, typically with low hazard potential, are often used to simulate the charging, reaction, and physical changes to be accomplished in the toll. Flow control, temperature control, pressure control, mixing and transferring efficiency can be measured. Mechanical integrity can be verified in regard to pumps, seals, vessels, heat exchangers, and safety devices. [Pg.103]

After catalyst charging and the flow vs. RPM measurement is done, the reactor should be closed and flushed out with nitrogen while the impeller runs, until O2 drops below a few tenths of a percent. Then a static pressure and leak test should be made by turning off the forward pressure controller and the flow controller. If an observable drop of pressure occurs within 15 minutes, all joints and connections should be checked for leaks and fixed before progressing any fijither. [Pg.87]

After the flov/ measurement, sample the discharge stream to a continuous Flame Ionization Detector (FID) that works as an Analyzer Indicator Transmitter CYIT). The Flow Controller (FC) reads the TCE concentration signal and adjusts the flow to keep the TCE at the set level of, say, 250 ppm. [Pg.95]

The correct flow to use is the compressor suction. However, a flow element such as an orifice in the compressor suction can rob inordinate horsepower. Therefore, sometimes the discharge flow is measured and the suction flow computed within the controller by using pressure measurements. Other times the compressor intake nozzle is calibrated and used as a flow element. The correct AP to use is the discharge minus the suction pressure. [Pg.121]

Figure 12-26. The SIMULAR reaction calorimeter. Features include pumped liquid feed, gas mass flow control, gas evolution measurement, and distillation equipment. (Source Hazard Evaluation Laboratory Ltd.)... Figure 12-26. The SIMULAR reaction calorimeter. Features include pumped liquid feed, gas mass flow control, gas evolution measurement, and distillation equipment. (Source Hazard Evaluation Laboratory Ltd.)...
Continuous in-line measurements and control of the mass material balance in the process, with automatic feedback to the reactants dosing devices (performed either by computerized system or by traditional flow control loops). [Pg.686]

The schematic diagram of the experimental setup is shown in Fig. 2 and the experimental conditions are shown in Table 2. Each gas was controlled its flow rate by a mass flow controller and supplied to the module at a pressure sli tly higher than the atmospheric pressure. Absorbent solution was suppUed to the module by a circulation pump. A small amount of absorbent solution, which did not permeate the membrane, overflowed and then it was introduced to the upper part of the permeate side. Permeation and returning liquid fell down to the reservoir and it was recycled to the feed side. The dry gas through condenser was discharged from the vacuum pump, and its flow rate was measured by a digital soap-film flow meter. The gas composition was determined by a gas chromatograph (Yanaco, GC-2800, column Porapak Q for CO2 and (N2+O2) analysis, and molecular sieve 5A for N2 and O2 analysis). The performance of the module was calculated by the same procedure reported in our previous paper [1]. [Pg.410]

Air was supplied from a compressor, moisture and particles in the air are removed passing a trap, and air flow rate was controlled by mass flow controller (5850E, Brooks Co.). The dry sorbents after the attrition were collected, then the particle sizes of them were measured by... [Pg.550]

An experimental fluidized bed reactor has a 2.5 cm in diameter and 230 cm in height, and the distributor has 32 holes and each hole was 2 mm in diameter. 200 mesh net was put on the distributor to prevent particles from falhng down. The cyclone was made by standard proportion to collect fine particles. Air flow rate was controlled by a flow meter, CO2 (99.9%) flow rate was controlled by mass flow controller and then 10% CO2 inlet concentration was maintained by mixing in a mixing chamber. CO2 outlet concentration was also measured by CO2 analyzer (CD 95, Geotechnical instruments, England). [Pg.550]

The catalysts were tested for their CO oxidation activity in an automated microreactor apparatus. The catalysts were tested at space velocities of 7,000 -60,000 hr . A small quantity of catalyst (typically 0.1 - 0.5 g.) was supported on a frit in a quartz microreactor. The composition of the gases to the inlet of the reactor was controlled by mass flow controllers and was CO = 50 ppm, CO2 = 0, or 7,000 ppm, HjO = 40% relative humidity (at 25°C), balance air. These conditions are typical of conditions found in spacecraft cabin atmospheres. The temperature of the catalyst bed was measured with a thermocouple placed half way into the catalyst bed, and controlled using a temperature controller. The inlet and outlet CO/CO2 concentrations were measured by non-dispersive infrared (NDIR) monitors. [Pg.428]

Fig. 2.6.10 Specialized experimental set-up for microfluidic flow dispersion measurements. Fluid is supplied from the top, flows via a capillary through the microfluidic device to be profiled and exits at the bottom. The whole apparatus is inserted into the bore of a superconducting magnet. Spatial information is encoded by MRI techniques, using rf and imaging gradient coils that surround the microfluidic device. They are symbolized by the hollow cylinder in the figure. After the fluid has exited the device, it is led through a capillary to a microcoil, which is used to read the encoded information in a time-resolved manner. The flow rate is controlled by a laboratory-built flow controller at the outlet [59, 60]. Fig. 2.6.10 Specialized experimental set-up for microfluidic flow dispersion measurements. Fluid is supplied from the top, flows via a capillary through the microfluidic device to be profiled and exits at the bottom. The whole apparatus is inserted into the bore of a superconducting magnet. Spatial information is encoded by MRI techniques, using rf and imaging gradient coils that surround the microfluidic device. They are symbolized by the hollow cylinder in the figure. After the fluid has exited the device, it is led through a capillary to a microcoil, which is used to read the encoded information in a time-resolved manner. The flow rate is controlled by a laboratory-built flow controller at the outlet [59, 60].
Mechanical rheometry requires a measurement of both stress and strain (or strain rate) and is thus usually performed in a simple rotating geometry configuration. Typical examples are the cone-and-plate and cylindrical Couette devices [1,14]. In stress-controlled rheometric measurements one applies a known stress and measures the deformational response of the material. In strain-controlled rheometry one applies a deformation flow and measures the stress. Stress-controlled rheometry requires the use of specialized torque transducers in conjunction with low friction air-bearing drive in which the control of torque and the measurement of strain is integrated. By contrast, strain-controlled rheometry is generally performed with a motor drive to rotate one surface of the cell and a separate torque transducer to measure the resultant torque on the other surface. [Pg.185]

In the secondary loop, the flow controller compares the desired fuel gas flow rate with the measured flow rate from the flow transducer (FT), and adjusts the regulating valve accordingly. [Pg.189]

What we can do easily is to measure the fuel gas flow rate, multiply the value by R in the so-called ratio station, and send the signal as the set point to the air flow controller. The calculation can be based on actual flow rates rather than deviation variables. [Pg.198]

Flow control will usually be based on the measurement of pressure drop across an orifice plate. [Pg.269]

For example, suppose a liquid is being pumped from one vessel into another vessel using a pump and under the action of flow control using an orifice plate to measure the flowrate. The head losses involved will be... [Pg.270]

Each step in the flow diagram is analysed to determine if it is suitable as a CCP for one or more of die hazards found using Principle 1. A production step is a CCP if it fulfils all of the following three requirements the step contains a control measure for the hazard lack of control at this step could lead to this hazard reaching an unacceptable level and subsequent steps are not going to eliminate the hazard. [Pg.492]


See other pages where Flow control measurement is mentioned: [Pg.472]    [Pg.472]    [Pg.1876]    [Pg.463]    [Pg.71]    [Pg.181]    [Pg.189]    [Pg.10]    [Pg.205]    [Pg.746]    [Pg.750]    [Pg.2169]    [Pg.93]    [Pg.96]    [Pg.548]    [Pg.256]    [Pg.630]    [Pg.449]    [Pg.1151]    [Pg.237]    [Pg.338]    [Pg.382]    [Pg.450]    [Pg.693]    [Pg.15]    [Pg.833]    [Pg.57]    [Pg.19]    [Pg.361]    [Pg.186]    [Pg.312]    [Pg.374]    [Pg.296]   


SEARCH



Control based on RQ and heat flow rate measurements

Control measurements

Control measures

Controllability measures

Flow control

Flow control and measurement

Flow controllers

Flow measurement

Flow measuring