Excitation in flames

Flame Sources Atomization and excitation in flame atomic emission is accomplished using the same nebulization and spray chamber assembly used in atomic absorption (see Figure 10.38). The burner head consists of single or multiple slots or a Meker-style burner. Older atomic emission instruments often used a total consumption burner in which the sample is drawn through a capillary tube and injected directly into the flame. [Pg.435]

Emission of electromagnetic radiation in the visible and ultraviolet regions of the spectrum by atoms after electronic excitation in flames. [Pg.312]

Non-equilibrium excitation in flames has been discussed from the point of view of possible inversions286. The possibility of laser action on several transitions of CN excited in active nitrogen has been discussed292 in terms of relevant rate equations and the threshold condition for oscillation. A chemical laser is of course a physical phenomenon, the performance of which depends critically on the rate... [Pg.173]

Another spectrum which has been suggested to be of value in monitoring O atoms is the iodine flame bands. Phillips and Sugden showed that the (4, 0) band of the 10 system is excited in flames, and its intensity is proportional to the local O atom concentration. [Pg.198]

Free radicals are produced when chemical bonds are broken by what is termed a homolytic process (13.144), as distinct from a heterolytic process in which ions are obtained (13.145). The former may be effected by thermal or photochemical means (thermolysis or photolysis), by excitation in flames, by electrolysis, by electron impact in mass spectrometers, or during radiochemical breakdown processes. [Pg.1294]

I. R. King, Comparison of ionization and electronic excitation in flames, J. Chem. Phys. 31, 855 (1959). [Pg.351]

Sensitivity Sensitivity in flame atomic emission is strongly influenced by the temperature of the excitation source and the composition of the sample matrix. Normally, sensitivity is optimized by aspirating a standard solution and adjusting the flame s composition and the height from which emission is monitored until the emission intensity is maximized. Chemical interferences, when present, decrease the sensitivity of the analysis. With plasma emission, sensitivity is less influenced by the sample matrix. In some cases, for example, a plasma calibration curve prepared using standards in a matrix of distilled water can be used for samples with more complex matrices. [Pg.440]

Sonoluminescence from nonaqueous Hquids has only recentiy been examined. Flint and SusHck reported the first MBSL spectra of organic Hquids (37). With various hydrocarbons, the observed emission is from excited states of (d Ilg — 11, the Swan lines), the same emission seen in flames. [Pg.259]

Atomic Absorption/Emission Spectrometry. Atomic absorption or emission spectrometric methods are commonly used for inorganic elements in a variety of matrices. The general principles and appHcations have been reviewed (43). Flame-emission spectrometry allows detection at low levels (10 g). It has been claimed that flame methods give better reproducibiHty than electrical excitation methods, owing to better control of several variables involved in flame excitation. Detection limits for selected elements by flame-emission spectrometry given in Table 4. Inductively coupled plasma emission spectrometry may also be employed. [Pg.243]

Under low-frequency excitation, the flame front is wrinkled by velocity modulations (Fig. 5.2.5). The number of undulations is directly linked to frequency. This is true as far as the frequency remains low (in this experiment, between 30 and 400 Hz). The flame deformation is created by hydrodynamic perturbations initiated at the base of the flame and convected along the front. When the velocity modulation amplitude is low, the undulations are sinusoidal and weakly damped as they proceed to the top of the flame. When the modulation amplitude is augmented, a toroidal vortex is generated at the burner outlet and the flame front rolls over the vortex near the burner base. Consumption is fast enough to suppress further winding by the structure as it is convected away from the outlet. This yields a cusp formed toward burnt gases. This process requires some duration and it is obtained when the flame extends over a sufficient axial distance. If the acoustic modulation level remain low (typically v /v < 20%),... [Pg.85]

Both emission and absorption spectra are affected in a complex way by variations in atomisation temperature. The means of excitation contributes to the complexity of the spectra. Thermal excitation by flames (1500-3000 K) only results in a limited number of lines and simple spectra. Higher temperatures increase the total atom population of the flame, and thus the sensitivity. With certain elements, however, the increase in atom population is more than offset by the loss of atoms as a result of ionisation. Temperature also determines the relative number of excited and unexcited atoms in a source. The number of unexcited atoms in a typical flame exceeds the number of excited ones by a factor of 103 to 1010 or more. At higher temperatures (up to 10 000 K), in plasmas and electrical discharges, more complex spectra result, owing to the excitation to more and higher levels, and contributions of ionised species. On the other hand, atomic absorption and atomic fluorescence spectrometry, which require excitation by absorption of UV/VIS radiation, mainly involve resonance transitions, and result in very simple spectra. [Pg.606]

Principles and Characteristics Flame emission instruments are similar to flame absorption instruments, except that the flame is the excitation source. Many modem instruments are adaptable for either emission or absorption measurements. Graphite furnaces are in use as excitation sources for AES, giving rise to a technique called electrothermal atomisation atomic emission spectrometry (ETA AES) or graphite furnace atomic emission spectrometry (GFAES). In flame emission spectrometry, the same kind of interferences are encountered as in atomic absorption methods. As flame emission spectra are simple, interferences between overlapping lines occur only occasionally. [Pg.615]

Hooymayers HP, Alkemade CTJ (1966) Quenching of excited alkali atoms and related effects in flames Part II. Measurements and discussion. J Quant Spectrosc Radiat Transfer 6 847-874... [Pg.354]

The ratio, Nj/N0, can therefore be calculated. For the relatively easily excited alkali metal sodium, it is 9.9 x 10 6 at 2000 °K and 5.9 x 10 4 at 3000 °K this latter temperature is about the highest commonly obtained with flames used for atomic absorption or emission work. Hence, only about 1(T3 % of the sodium atoms are excited at 2000 ° and 6 x 1(F2 % at 3000°. For an element such as zinc,Nf/N0 is 5.4 x 10"10 at 3000 and so only 5 x 10"8% is excited. In spite of the small fraction excited, good sensitivities can be obtained for many elements by flame photometry if a high temperature flame is used, because the difference between zero and a small but finite number is measured. For example, seventy elements can be determined by flame photometry using the nitrous oxide-acetylene flame 1H. [Pg.81]

The basic instrumentation used for spectrometric measurements has already been described in the previous chapter (p. 277). Methods of excitation, monochromators and detectors used in atomic emission and absorption techniques are included in Table 8.1. Sources of radiation physically separated from the sample are required for atomic absorption, atomic fluorescence and X-ray fluorescence spectrometry (cf. molecular absorption spectrometry), whereas in flame photometry, arc/spark and plasma emission techniques, the sample is excited directly by thermal means. Diffraction gratings or prism monochromators are used for dispersion in all the techniques including X-ray fluorescence where a single crystal of appropriate lattice dimensions acts as a grating. Atomic fluorescence spectra are sufficiently simple to allow the use of an interference filter in many instances. Photomultiplier detectors are used in every technique except X-ray fluorescence where proportional counting or scintillation devices are employed. Photographic recording of a complete spectrum facilitates qualitative analysis by optical emission spectrometry, but is now rarely used. [Pg.288]

Table 8.7). Thus, intensity and concentration are directly proportional. However, the intensity of a spectral line is very sensitive to changes in flame temperature because such changes can have a pronounced effect on the small proportion of atoms occupying excited levels compared to those in the ground state (p. 274). Quantitative measurements are made by reference to a previously prepared calibration curve or by the method of standard addition. In either case, the conditions for measurement must be carefully optimized with reference to the choice of emission line, flame temperature, concentration range of samples and linearity of response. Relative precision is of the order of 1-4%. Flame emission measurements are susceptible to interferences from numerous sources which may enhance or depress line intensities. [Pg.318]

Even in these cases, over 90% of such atoms are likely to remain in the ground state if cooler flames, e.g. air-propane, are used (Table 8.7). The situation should be contrasted with that encountered in flame photometry which depends on the emission of radiation by the comparatively few excited atoms present in the flame. However, because of fundamental differences between absorption and emission processes it does not follow that atomic absorption is necessarily a more sensitive technique than flame emission. [Pg.321]

Ideally, the emission line used should have a half-width less than that of the corresponding absorption line otherwise equation (8.4) will be invalidated. The most suitable and widely used source which fulfils this requirement is the hollow-cathode lamp, although interest has also been shown in microwave-excited electrodeless discharge tubes. Both sources produce emission lines whose halfwidths are considerably less than absorption lines observed in flames because Doppler broadening in the former is less and there is negligible collisional broadening. [Pg.326]

Flame photometric (FPD) Light emission of excited species in flame 2-50 pg/s 3 Compounds containing P and S... [Pg.474]

Therefore, the fraction of atoms excited critically depends on the temperature of the flame thereby emphasizing the vital importance of controlling the temperature in Flame Emission Spectroscopy (FES). [Pg.372]


See other pages where Excitation in flames is mentioned: [Pg.236]    [Pg.124]    [Pg.250]    [Pg.206]    [Pg.236]    [Pg.124]    [Pg.250]    [Pg.206]    [Pg.156]    [Pg.109]    [Pg.317]    [Pg.317]    [Pg.319]    [Pg.418]    [Pg.773]    [Pg.781]    [Pg.783]    [Pg.7]    [Pg.149]    [Pg.150]    [Pg.663]    [Pg.609]    [Pg.286]    [Pg.28]    [Pg.235]    [Pg.240]    [Pg.49]    [Pg.50]    [Pg.78]    [Pg.154]    [Pg.154]    [Pg.12]   