Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Exact methods

The high accuracy of spatial and density resolution can be obtained by using exact methods. Thus it is necessary to apply of complete scanning geometry. The analysis of variants of scanning shows that the geometry sine on the cylinder is perspectiv enough by its characteristics. [Pg.219]

The exact methods employed to prepare any particular surface for study vary from material to material, and are usually detennined empirically. In some respects, sample preparation is more of an art than a science. Thus, it is always best to consult the literature to look for preparation methods before starting with a new material. [Pg.302]

Unfortunately, the resources required for these numerically exact methods grow exponentially with the number of degrees of freedom in the system of interest. Without the use of clever algorithms to optimize the basis set used [106,107], this limits the range of systems treatable to 4-6 degrees of freedom (3-4 atoms). For larger systems, the MCTDH method [19,20,108] provides a... [Pg.259]

Whereas it is generally sufficient (at least for the pubhshed methods) to specify the semi-empirical MO technique used in order to define the exact method used for the calculations, ab-initio theory offers far more variations, so that the exact level of the calculation must be specified. The starting point of most ab-initio jobs is an SCF calculation analogous to those discussed above for semi-empirical MO calculations. In ab-initio theory, however, all necessary integrals are calculated correctly, so that the calculations are very much (by a factor of about 1000) more time-consuming than their semi-empirical counterparts. [Pg.384]

With better hardware and software, more exact methods can be used for the representation of chemical structures and reactions. More and more quantum mechanical calculations can be utilized for chemoinformatics tasks. The representation of chemical structures will have to correspond more and more to our insight into theoretical chemistry, chemical bonding, and energetics. On the other hand, chemoinformatics methods should be used in theoretical chemistry. Why do we not yet have databases storing the results of quantum mechanical calculations. We are certain that the analysis of the results of quantum mechanical calculations by chemoinformatics methods could vastly increase our chemical insight and knowledge. [Pg.624]

In determining the values of Ka use is made of the pronounced shift of the UV-vis absorption spectrum of 2.4 upon coordination to the catalytically active ions as is illustrated in Figure 2.4 ". The occurrence of an isosbestic point can be regarded as an indication that there are only two species in solution that contribute to the absorption spectrum free and coordinated dienophile. The exact method of determination of the equilibrium constants is described extensively in reference 75 and is summarised in the experimental section. Since equilibrium constants and rate constants depend on the ionic strength, from this point onward, all measurements have been performed at constant ionic strength of 2.00 M usir potassium nitrate as background electrolyte . [Pg.58]

In the previous section we described several internal methods of quality assessment that provide quantitative estimates of the systematic and random errors present in an analytical system. Now we turn our attention to how this numerical information is incorporated into the written directives of a complete quality assurance program. Two approaches to developing quality assurance programs have been described a prescriptive approach, in which an exact method of quality assessment is prescribed and a performance-based approach, in which any form of quality assessment is acceptable, provided that an acceptable level of statistical control can be demonstrated. [Pg.712]

Finishing. AH acetal resins contain various stabilizers introduced by the suppHer in a finishing extmsion (compounding) step. The particular stabilizers used and the exact method of their incorporation are generally not revealed. Thermal oxidative and photooxidative stabilizers have already been mentioned. These must be carefully chosen and tested so that they do not aggravate more degradation (eg, by acidolysis) than they mitigate. [Pg.58]

Linking this molecular model to observed bulk fluid PVT-composition behavior requires a calculation of the number of possible configurations (microstmctures) of a mixture. There is no exact method available to solve this combinatorial problem (28). ASOG assumes the athermal (no heat of mixing) FIory-Huggins equation for this purpose (118,170,171). UNIQUAC claims to have a formula that avoids this assumption, although some aspects of athermal mixing are still present in the model. [Pg.252]

Tinkler and Metzner (1961) executed a large number of computations for simultaneous equations by approximate and exact methods and presented their results on numerous graphs. One of those is shown in Figure 1.6.1. Please note that on this figure the parameter is e=y P De/at in the notation of this book, and the abscissa = is the Thiele modulus. [Pg.27]

For non-New tonian fluids, viscosity data are very important. Every impeller has an average fluid shear rate related to speed. For example, foi a flat blade turbine impeller, the average impeller zone fluid shear rate is 11 times the operating speed. The most exact method to obtain the viscosity is by using a standard mixing tank and impeller as a viscosimeter. By measuring the pow er response on a small scale mixer, the viscosity at shear rates similar to that in the full scale unit is obtained. [Pg.207]

The oxidation products of camphene are of considerable interest, but as they vary very considerably according to the exact method of oxidation employed, they are not of very great use in the characterisation of the terpene. [Pg.52]

Slack, J. B., Steam Balance A New Exact Method, Hydrocarbon Processing Mar. 1969, p. 154. [Pg.50]

To have some idea of what value to use in Colburn s exact method for minimum reflux, use Colburn s approximate method to establish the order-of-magni-tude of the minimum reflux ... [Pg.77]

In decreasing order of exactness, methods of defining viscosity include absolute (poise) viscosity kinematic viscosity in centistokes relative viscosity in Saybolt universal seconds (SUS) and SAE numbers. [Pg.598]

The provision of a separate oil cooler will reduce condenser load by the amount of heat lost to the oil and removed in the oil cooler. This is of special note with twin-screw compressors, where a high proportion of the compressor energy is taken away in the oil. This proportion varies with the exact method of oil cooling, and figures should be obtained from the compressor manufacturer for a particular application. [Pg.65]

Metal and polysilicon films are formed by a chemical-vapor deposition process using organometallic gases that react at the surface of the IC structure. Various metal silicide films may also be deposited in this manner by reaction with the surface of the silicon wafer to form metal silicides. Glass and pol3uner films are deposited or spin cast or both, as are photoresist films (those of a photosensitive material). This process is accomplished by applying a liquid polymer onto a rapidly rotating wafer. The exact method used varies from manufacturer to manufacturer and usually remains proprietary. [Pg.329]

Two different methods were used to produce Iron oxide (Fe203) particles on Grafoll. One method was a simple Impregnation-calcination based on the method of Bartholomew and Boudart (20). The exact method used 1s described elsewhere (27). The second method used was a two step process. First, metallic iron particles were produced on the Grafoll surface via the thermal decomposition of Iron pentacarbonyl. This process Is also described in detail elsewhere (25). Next, the particles were exposed to air at room atmosphere and thus partially oxidized to 2 3 Following the production of Iron oxide particles (by... [Pg.522]

Most exact methods Correlations between the Shifts of v(m for a Thermal stability... [Pg.103]

Molecular weights of polysilane polymers depend upon the exact method of synthesis, as well as the purity of the dichlorosilane starting materials. Bimodal molecular weight distributions are commonly reported, as shown in Figure 1, but under some conditions... [Pg.8]

In cases where x is too large to neglect from the concentration from which it is subtracted, a more exact method is required. The quadratic formula is an exact method to determine the value of x in a equation of the form... [Pg.305]

The value of this ratio is characteristic of the reaction order. Table 3.1 contains a tabulation of partial reaction times for various rate expressions of the form r = kCAn as well as a tabulation of some useful ratios of reaction times. By using ratios of the partial reaction times based on experimental data, one is able to obtain a quick estimate of the reaction order with minimum effort. Once this estimate is in hand one may proceed to use a more exact method of determining the reaction rate parameters. [Pg.57]

In-situ Fourier transform infrared spectroscopy. The final technique in this section concerns the FTIR approach which is based quite simply on the far greater throughput and speed of an FTIR spectrometer compared to a dispersive instrument. In situ FTIR has several acronyms depending on the exact method used. In general, as in the EMIRS technique, the FTIR-... [Pg.111]

LOD is defined as the lowest concentration of an analyte that produces a signal above the background signal. LOQ is defined as the minimum amount of analyte that can be reported through quantitation. For these evaluations, a 3 x signal-to-noise ratio (S/N) value was employed for the LOD and a 10 x S/N was used to evaluate LOQ. The %RSD for the LOD had to be less than 20% and for LOQ had to be less than 10%. Table 6.2 lists the parameters for the LOD and LOQ for methyl paraben and rhodamine 110 chloride under the conditions employed. It is important to note that the LOD and LOQ values were dependent upon the physicochemical properties of the analytes (molar absorptivity, quantum yield, etc.), methods employed (wavelengths employed for detection, mobile phases, etc.), and instrumental parameters. For example, the molar absorptivity of methyl paraben at 254 nm was determined to be approximately 9000 mol/L/cm and a similar result could be expected for analytes with similar molar absorptivity values when the exact methods and instrumental parameters were used. In the case of fluorescence detection, for most applications in which the analytes of interest have been tagged with tetramethylrhodamine (TAMRA), the LOD is usually about 1 nM. [Pg.174]

The exact method by which fracture occurs is not known, although it is suggested by I>r r i i 51 that the compressive force produces small flaws in the material. If the energy concentration exceeds a certain critical value, these flaws will grow rapidly and will generally branch, and the particles will break up. The probability of fracture of a particle... [Pg.98]

There are a variety of thermal modification methods that can be applied to wood, and the exact method of treatment can have a significant effect upon the properties of the thermally modified wood. Important process variables include the following ... [Pg.100]

B. Analytical Properties of Exact Methods The Localization Method. ... [Pg.73]


See other pages where Exact methods is mentioned: [Pg.217]    [Pg.219]    [Pg.617]    [Pg.196]    [Pg.67]    [Pg.185]    [Pg.65]    [Pg.374]    [Pg.73]    [Pg.86]    [Pg.50]    [Pg.592]    [Pg.392]    [Pg.174]    [Pg.91]    [Pg.501]    [Pg.60]    [Pg.382]    [Pg.10]    [Pg.3]    [Pg.656]    [Pg.65]    [Pg.99]   
See also in sourсe #XX -- [ Pg.48 , Pg.112 , Pg.113 , Pg.127 , Pg.133 , Pg.142 , Pg.191 ]




SEARCH



Exact

Exactive

Exactness

© 2024 chempedia.info