Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Equipment boilers

Turbidity None, usually expressed in Jackson Turbidity Units Imparts unsightly appearance to water deposits in water lines, process equipment, boilers, etc. interferes with most process uses Coagulation, settling, and filtration... [Pg.146]

Hardness Calcium, magnesium, barium and strontium salts expressed as CaCOa Chief source of scale in heat exchange equipment, boilers, pipe lines, etc. forms curds with soap interferes wKh dyeing, etc. Softening, distillation, internal boiler water treatment, surface active agents, reverse osmosis, electrodialysis... [Pg.146]

Oxygen O2 Corrosion of water lines, heat exchange equipment, boilers, return lines, etc. Deaeration, sodium sulflte, corrosion inhibitors, hydrazine or suitable substitutes... [Pg.146]

Suspended Solids None Suspended Solids is the measure of undissolved matter, determined gravimetrically suspended solids plug lines, cause deposits in heat exchange equipment, boilers, etc. Subsidence, filtration, usually preceded by coagulation and settling... [Pg.147]

Control technologies employed for the handling of air emissions normally include the capture and recycling or combustion of emissions from vents, product transfer points, storage tanks, and other handling equipment. Boilers, heaters, other combustion devices, cokers, and catalytic units may require paniculate matter controls. Use of a carbon monoxide boiler is normally a standard practice... [Pg.106]

Hardness Calcium and magnesium salts in the forms of CaCOj, Ca, Mg. This is the primary source of scaling in heat exchange equipment, boilers, pipelines/transfer lines, etc. Tends to form curds with soap and interferes with dyeing applications as well. [Pg.375]

Final drawings should be made after the equipment, boilers, and other machinery have been decided upon, for they can then be drawn completely and accurately. At least two views should be drawn, a plan and... [Pg.364]

There shall be a special budget for items for personal safety and ETP and for expenses required to comply with instructions from statutory inspectors work on pressure vessels, electrical equipments, boilers). [Pg.302]

Engineering guidelines produced by Factory Mutual (FM) to help reduce the risk of property loss due to fire, weather, and/or electrical or mechanical equipment failure. They are based on input from loss experience, research results, consensus standards committees, equipment manufacturers, and other interested participants. The subjects covered include construction, sprinklers, water supply, extinguishing equipment, electrical equipment, boilers and industrial heating equipment, hazards, storage, miscellaneous, human factors, systems instrumentation and control, pressure vessels, mechanical, welding, and boiler and machinery. They may also be referred to as FM Global Property Loss Prevention Data Sheets. See also Factory Mutual (FM). [Pg.135]

Hardness Calcium and magnesium salts expressed as CaCOj Chief source of scale in heat exchange equipment, boilers, pipelines, and so on. Forms curds with soap, interferes with dyeing, and so on. Softening. Demineralization. Internal boiler water treatment. Surface active agents. [Pg.271]

Chief source of scale in heat-exchange equipment, boilers, pipelines, etc. [Pg.88]

Buildings that contain unclassified electrical equipment Boilers... [Pg.237]


See other pages where Equipment boilers is mentioned: [Pg.864]    [Pg.376]    [Pg.141]    [Pg.688]    [Pg.868]    [Pg.117]    [Pg.115]   
See also in sourсe #XX -- [ Pg.283 ]




SEARCH



Equipment Rotating boiler

Equipment design boilers