Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Eluent specific

Sugar analysis by hplc has advanced greatly as a result of the development of columns specifically designed for carbohydrate separation. These columns fall into several categories. (/) Aminopropyl-bonded siHca used in reverse-phase mode with acetonitrile—water as the eluent. (2) Ion-moderated cation-exchange resins using water as the eluent. Efficiency of these columns is enhanced at elevated temperature, ca 80—90°C. Calcium is the usual counterion for carbohydrate analysis, but lead, silver, hydrogen, sodium, and potassium are used to confer specific selectivities for mono-, di-, and... [Pg.10]

The desorption efficiencies given are directly related to the eluent used. All data in the desorption efficiency column correspond to the specific eluent listed ... [Pg.329]

In most situations the eluent composition is chosen to minimize the effects of hydrophobic interaction, but these secondary effects can be used to advantage. By careful selection of a salt and its concentration, specific selectivities for analytes can be achieved without the use of organic solvents. Therefore, many separations usually run by solvent gradient reversed-phase methods can be completed with a purely aqueous isocratic eluent (13,14). [Pg.117]

Three different types of columns packed with gels of different pore sizes are available. Columns should be selected that are suitable for the molecular weight range of specific samples, as each type has a different exclusion limit (Fig. 6.41, page 215). Bovine serum albumin (BSA), myoglobin, and lysozyme show good peak shapes using only 100 mM of sodium phosphate buffer as an eluent. There is no need to add any salt to the eluent to reduce the ionic interaction between protein and gel. [Pg.205]

The low polarity of CO,-based eluents makes SFC a normal phase technique. Therefore, it is not surprising that most of the successful applications of chiral SFC have utilized CSPs designed for normal phase LC. Flowever, some exceptions have been noted. Specific applications of various CSPs are outlined in the next sections. [Pg.307]

Some authors have suggested the use of fluorene polymers for this kind of chromatography. Fluorinated polymers have attracted attention due to their unique adsorption properties. Polytetrafluoroethylene (PTFE) is antiadhesive, thus adsorption of hydrophobic as well as hydrophilic molecules is low. Such adsorbents possess extremely low adsorption activity and nonspecific sorption towards many compounds [109 111]. Fluorene polymers as sorbents were first suggested by Hjerten [112] in 1978 and were tested by desalting and concentration of tRN A [113]. Recently Williams et al. [114] presented a new fluorocarbon sorbent (Poly F Column, Du Pont, USA) for reversed-phase HPLC of peptides and proteins. The sorbent has 20 pm in diameter particles (pore size 30 nm, specific surface area 5 m2/g) and withstands pressure of eluent up to 135 bar. There is no limitation of pH range, however, low specific area and capacity (1.1 mg tRNA/g) and relatively low limits of working pressure do not allow the use of this sorbent for preparative chromatography. [Pg.167]

To purify, concentrate, and recover different pigments (flavonoids or anthocya-nins), various ion-changing resins were used. Recent screenings of 13 commercial resins [acrylic or styrene-divinylbenzene (SDVB)] for the purification and specific absorption of anthocyanins - used ethanol, methanol, and water mixtures as eluents at pH 3.5. DDVB resins (EXA-118 and EXA-90) were found most suitable using a mixture of methanol and water (1 1) for elution. The other routinely used resins like XAD-7 showed low efficiency. [Pg.313]

Specific eluents are most frequently used with group-specific adsorbents since selectivity is greatly increased in the elution step. [Pg.81]

IEC continues to have numerous applications to the detection and quantification of various inorganic ions.1 1 This is particularly true in water analysis.5-14 Inorganic ions in a variety of other sample types, such as food and beverages,1518 rocks,19-23 biological fluids, (blood, urine, etc.),24-31 pharmaceutical substances,32 33 concentrated acids,34 alcohols,35 and cleanroom air36 have also been analyzed by IEC. IEC has also been employed in isotopic separation of ions,37 including the production of radioisotopes for therapeutic purposes.3839 Typical IEC sample matrices are complex, and may contain substances that interfere with measurement of the ion(s) of interest. The low detection limits required for many IEC separations demand simple extraction procedures and small volumes to avoid over-dilution. Careful choice and manipulation of the eluent(s) may be needed to achieve the desired specificity, especially when multiple ions are to be determined in a single sample. [Pg.287]

Other kinds of bloassays have been used to detect the presence of specific allelochemical effects (8), effects on N2 fIxatlon (9), the presence of volatile compounds (10) and of Inhibitory substances produced by marine microalgae (11). Putnam and Duke (12) have summarized the extraction techniques and bioassay methods used In allelopathy research. Recent developments In high performance liquid chromatography (HPLC) separation of allelochemlcals from plant extracts dictates the need for bloassays with sensitivity to low concentrations of compounds contained In small volumes of eluent. Einhellig at al. (13) described a bloassay using Lemna minor L. growing In tissue culture cluster dish wells that maximizes sensitivity and minimizes sample requirements. [Pg.198]

On-line LC-MS undoubtedly is a more important and versatile identification technique than LC-FTIR. However, there is no single universal LC-MS interface available every interface has its specific limitations with regard to flow-rate and composition of the LC eluent, polarity and molecular mass of the analytes, and/or ionisation technique(s) that can be used. For the non-mass spectroscopist, LC-MS developments have been a rather confusing matter. The developments of 30 years of LC-MS can be summarised as follows ... [Pg.489]

An alternative system proved to be both simpler and more user friendly (Unger et al., 2004 Machtejevas et al., 2006). Thus far we have used this configuration to analyze human plasma, sputum, urine, cerebrospinal fluid, and rat plasma. For each particular analysis we set up an analytical system based on a simple but specific strategy (Figure 9.5). The analysis concept is based on an online sample preparation and a two-dimensional LC system preseparating the majority of the matrix components from the analytes that are retained on a RAM-SCX column followed by a solvent switch and transfer of the trapped peptides. The SCX elution used five salt steps created by mixing 20 mM phosphate buffer (pH 2.5) (eluent Al) and 20 mM phosphate buffer with 1.5 M sodium chloride (eluent Bl) in the following proportions 85/15 70/30 65/45 45/55 0/100 with at the constant 0.1 mL/min flow rate. Desorption of the... [Pg.214]


See other pages where Eluent specific is mentioned: [Pg.13]    [Pg.206]    [Pg.13]    [Pg.206]    [Pg.352]    [Pg.2063]    [Pg.355]    [Pg.126]    [Pg.252]    [Pg.265]    [Pg.170]    [Pg.178]    [Pg.196]    [Pg.22]    [Pg.31]    [Pg.81]    [Pg.196]    [Pg.298]    [Pg.719]    [Pg.791]    [Pg.813]    [Pg.914]    [Pg.11]    [Pg.58]    [Pg.234]    [Pg.267]    [Pg.272]    [Pg.489]    [Pg.489]    [Pg.562]    [Pg.244]    [Pg.276]    [Pg.27]    [Pg.215]    [Pg.108]    [Pg.226]   
See also in sourсe #XX -- [ Pg.363 ]




SEARCH



Eluent

Eluent specific consumption

Eluents

© 2024 chempedia.info