In most instances, the FBC is of the forced-air type with a single fluidizing blower at the front end. A total system including the air pollution control system is shown in Fig. 4. If the downstream heat recovery or air pollution control devices are unable to withstand pressure, an induced draft fan may be added to provide a balanced draft. Balanced draft systems are also utilized to provide a negative pressure in the FBC so that difficult-to-move materials can be fed via gravity through a chute-and-airlock arrangement. [Pg.155]

Where there is a temperature difference between the object to be weighed and the surrounding air, air currents will be induced close to the object s surface (12). These can be significant if extreme accuracy is required. Objects should be allowed to reach thermal equiHbrium in the laboratory before weighing. Just as important, the balance should be designed to minimize the temperature rise inside the weighing chamber. In extreme cases, the object should be placed inside the chamber until it reaches thermal equiHbrium before weighing. Needless to say, drafts must be avoided. [Pg.331]

The steam generator is a balanced draft, controlled circulation, multichamber unit which incorporates NO control and final burnout of the fuel-rich MHD combustion gases. The MHD generator exhaust is cooled in a primary radiant chamber from about 2310 to 1860 K in two seconds, and secondary air for afterburning and final oxidation of the gas is introduced in the secondary chamber where seed also condenses. Subsequent to afterburning and after the gas has been cooled down sufftciendy to soHdify condensed seed in the gas, the gas passes through the remaining convective sections of the heat recovery system. [Pg.425]

Plant layout and noise suppression material are two general noise abatement methods. Plant layout does not affect noise levels at any given point however, noise can be abated by screening off a section of the plant. An example of this is to orient cooling towers with their closed faces toward the critical location. This method must also consider wind direction to balance air draft. Tankage can be located to act as a noise screen. [Pg.83]

H is placed at the highest available level (Note 5) and connected with the tubes 7, 7, and K in such a manner as to secure a pressure of liquid sufficient to more than balance the steam pressure (Note 6). E and F are specially constructed condensers of unusual length (160 cm. and 85 cm., respectively) and bore (40 mm.) made from large glass tubing and rubber stoppers (Note 7). I he top of condenser E is connected to a good draft chamber. [Pg.87]

Drafts from windows and doors can have speeds that exceed that through the face of the enclosure. This can be especially so where the makeup air does not balance the amount extracted by the endosure(s). Doors should be kept closed unless the room has been specifically designed to operate otherwise. [Pg.880]

The reaction engineering model links the penetration theory to a population balance that includes particle formation and growth with the aim of predicting the average particle size. The model was then applied to the precipitation of CaC03 via CO2 absorption into Ca(OH)2aq in a draft tube bubble column and draws insight into the phenomena underlying the crystal size evolution. [Pg.255]

Figure 1-36. Process engineering costs (1975), based on process engineering charged at 14 per manhour. Chemical plant engineering operations, includes flowsheet development and drafting, material and heat balances, equipment designs, ratings, checking, and bid reviews and selection of equipment. By permission, E. E. Ludwig [7]. Figure 1-36. Process engineering costs (1975), based on process engineering charged at 14 per manhour. Chemical plant engineering operations, includes flowsheet development and drafting, material and heat balances, equipment designs, ratings, checking, and bid reviews and selection of equipment. By permission, E. E. Ludwig [7].
The economics of forced and induced draft cooling tower operation require a study of fan and water pump horsepower and usually dictate a fan static pressure requirement not to exceed 0.75-1.0 in. of water. For atmospheric and natural draft towers the economics of pumping water are still very important. This means that the ground area must be so selected as to keep the height dovm while not dropping the unit rates so low that performance becomes poor. This then, is a balance of ground area versus total deck height. Pritchard [16] presents an... [Pg.391]

Successful flue design involves the balancing of the draft against the resistance, possibly for a range of thermal inputs, the avoidance of condensation, and a location of the terminal that ensures unrestricted dispersion of the flue products. [Pg.268]

In the balanced flue, which may be natural draft or fan-assisted, the flue outlet and combustion air inlet are integral in a housing to be mounted on an outside vertical wall. As the flue and the inlet are subject to the same outside pressure, they are unaffected by it and are in balance. No provision for ventilation is needed and the appliance is room-sealed. [Pg.270]

This is a very versatile stoker common in shell boilers and is used with modification in watertube boilers as the traveling-grate stoker. In shell boilers, the air supply is via forced- and induced-draft fans in combination with a balanced or slightly negative condition in the furnace. [Pg.379]

NOTE Modem power boilers are designed for complete water-wall cooling (no boiler bank). They have very large superheaters, employ balanced draft systems, and typically do not have a mud drum. [Pg.42]

Large WT boilers generally have a balanced draft system (i.e., a combination of both FD and ID fans) and usually operate at negative furnace pressure (-0.1 to -0.5 inch of water) to provide for better control of both the furnace flue-gas pressure and the fuel-air combustion process. [Pg.86]

NOTE One inch of height difference in a U-tube manometer represents 0.0361 psia. A typical draft in a large balanced-draft WT boiler is on the order of 2 to 4 inches. [Pg.86]

A system of balancing induced draft and forced draft to a large WT boiler controlled primarily by dampers. In fact, large WT boilers tend to be specifically designed to operate at a slightly negative furnace pressure. [Pg.716]

A similar expression can be written for the pressure balance in the draft tube as ... [Pg.241]

The flow rate of particles in the downcomer and the draft tube are related by a mass balance as follows ... [Pg.241]

Rams JM, Pilgrim M, Rauth S, et al. 1979. Level II materials balance carbon tetrachloride (Draft Report). Washington, DC U.S. Environmental Protection Agency, Office of Pesticides and Toxic Substances. [Pg.180]

Ash, Shall not exceed 0.01 %. For this test, a 50g sample is weighed on a triplebeam balance into a dish, previously tared on an analytical balance, and heated over a free flame until the vapors continue 00 bum after removing the frame. (During the operation the sample should be protected from drafts). When the combustion dies out, ignite the residue at low red heat (or in a muffle fumace at 800°) until the carbonaceous matter is consumed, then cool in a desiccator weigh... [Pg.730]


See other pages where Draft balancing is mentioned: [Pg.260]    [Pg.263]    [Pg.385]    [Pg.391]    [Pg.752]    [Pg.301]    [Pg.260]    [Pg.263]    [Pg.385]    [Pg.391]    [Pg.752]    [Pg.301]    [Pg.331]    [Pg.20]    [Pg.807]    [Pg.54]    [Pg.716]    [Pg.788]    [Pg.34]    [Pg.263]    [Pg.179]    [Pg.34]    [Pg.588]    [Pg.549]    [Pg.101]    [Pg.163]    [Pg.419]    [Pg.514]    [Pg.17]   