Determinate error Determine

Identifying Determinate Errors Determinate errors can be difficult to detect. Without knowing the true value for an analysis, the usual situation in any analysis with meaning, there is no accepted value with which the experimental result can be compared. Nevertheless, a few strategies can be used to discover the presence of a determinate error. [Pg.60]

Before suggesting an approach for predicting the minimum number of shells for an entire network, a more convenient method for determining the number of shells in a single unit must first be found. Adopting the design criterion given by Eq. (7.13) as the basis, then any need for trial and error can be eliminated, since an explicit... [Pg.225]

The accuracy depends on the fraction distilled it deviates particularly when determining the initial and final boiling points the average error can exceed 10°C. When calculating the ASTM D 86 curve for gasoline, it is better to use the Edmister (1948) relations. The Riazi and Edmister methods lead to very close results when they are applied to ASTM D 86 calculations for products such as gas oils and kerosene. [Pg.164]

The model is predictive and uses a method of contributing groups to determine the parameters of interaction with water. It is generally used by simulation programs such as HYSIM or PR02. Nevertheless the accuracy of the model is limited and the average error is about 40%. Use the results with caution. [Pg.170]

The error attributed to the determination of the NHV (calorimetric measurement, determination of hydrogen content, and final calculation) is satisfactory with a repeatability of 0.3% and a reproducibility of 0.4%. [Pg.181]

The first of them to determine the LMA quantitatively and the second - the LF qualitatively Of course, limit of sensitivity of the LF channel depends on the rope type and on its state very close because the LF are detected by signal pulses exceeding over a noise level. The level is less for new ropes (especially for the locked coil ropes) than for multi-strand ropes used (especially for the ropes corroded). Even if a skilled and experienced operator interprets a record, this cannot exclude possible errors completely because of the evaluation subjectivity. Moreover it takes a lot of time for the interpretation. Some of flaw detector producers understand the problem and are intended to develop new instruments using data processing by a computer [6]. [Pg.335]

Analogous methods are used to calculated the measuring error related to inexact measuring of voltage Ur and/or Up. It is counted that the value of U is determined with measuring error 5%. The measuring error 5hu-, Shut at too low and high value of U are separately analyzed. [Pg.649]

The data from Table 2 show that the algorithm developed in allows sizing of different cracks with complex cross-sections and unknown shapes for orientation angles not exceeding 45°. It is seen that the width 2a and the parameter c (or the surface density of charge m=4 r // e at the crack walls) are determined with 100% accuracy for all of the Case Symbols studied. The errors in the computation of the depths dj and di are less than 4% while the errors in the computation of d, dj, d, and d are less than 20% independent of the shape of the investigated crack and its orientation angle O <45°. [Pg.691]

In the case of Langmuir monolayers, film thickness and index of refraction have not been given much attention. While several groups have measured A versus a, [143-145], calculations by Knoll and co-workers [146] call into question the ability of ellipsometry to unambiguously determine thickness and refractive index of a Langmuir monolayer. A small error in the chosen index of refraction produces a large error in thickness. A new microscopic imaging technique described in section IV-3E uses ellipsometric contrast but does not require absolute determination of thickness and refractive index. Ellipsometry is routinely used to successfully characterize thin films on solid supports as described in Sections X-7, XI-2, and XV-7. [Pg.126]

However, in many applications the essential space cannot be reduced to only one degree of freedom, and the statistics of the force fluctuation or of the spatial distribution may appear to be too poor to allow for an accurate determination of a multidimensional potential of mean force. An example is the potential of mean force between two ions in aqueous solution the momentaneous forces are two orders of magnitude larger than their average which means that an error of 1% in the average requires a simulation length of 10 times the correlation time of the fluctuating force. This is in practice prohibitive. The errors do not result from incorrect force fields, but they are of a statistical nature even an exact force field would not suffice. [Pg.22]

The shear viscosity is a tensor quantity, with components T] y, t],cz, T)yx> Vyz> Vzx> Vzy If property of the whole sample rather than of individual atoms and so cannot be calculat< with the same accuracy as the self-diffusion coefficient. For a homogeneous fluid the cor ponents of the shear viscosity should all be equal and so the statistical error can be reducf by averaging over the six components. An estimate of the precision of the calculation c then be determined by evaluating the standard deviation of these components from tl average. Unfortunately, Equation (7.89) cannot be directly used in periodic systems, evi if the positions have been unfolded, because the unfolded distance between two particl may not correspond to the distance of the minimum image that is used to calculate the fore For this reason alternative approaches are required. [Pg.397]

Provided that the balance is functioning correctly, the main source of error is in the weights themselves these should be calibrated by one of the standard methods so that their relative values are known, and they should be carefully cleaned with tissue paper and checked from time to time. To make the best use of the balance, weighing should be carried out by the method of swings, but for this purpose it is necessary first to determine the sensitivity of the balance. [Pg.465]

The source of carbon dioxide. The main requirement of the carbon dioxide supply is that it shall be air-free. It is, however, almost impossible to generate carbon dioxide, by any fairly simple method, so that it is completely free from air. Nevertheless, it is possible to obtain the gas sufficiently pure so that no serious error is introduced into the determination. [Pg.482]

Plot the probability density obtained from E in Problem 9 as a function of r, that is, simply square the function above with an appropriate scale factor as determined by trial and error. Comment on the relationship between your plot and the shell structure of the atom. [Pg.30]

Procedure. Run one or more simultaneous equation programs to determine the C—C and C—H bond energies and interpret the results. The error veetor is the veetor of ealeulated values minus the veetor of bond enthalpies taken as tme from an aeeepted source. Caleulate the enor veetor using a standard souree of bond enthalpies (e.g., Laidler and Meiser, 1999 or Atkins, 1994). Expand the method for 2-butene (2-butene) = —11 kJ mol ] and so obtain the C—H, C—C,... [Pg.56]

The mathematical requirements for unique determination of the two slopes mi and ni2 are satisfied by these two measurements, provided that the second equation is not a linear combination of the first. In practice, however, because of experimental error, this is a minimum requirement and may be expected to yield the least reliable solution set for the system, just as establishing the slope of a straight line through the origin by one experimental point may be expected to yield the least reliable slope, inferior in this respect to the slope obtained from 2, 3, or p experimental points. In univariate problems, accepted practice dictates that we... [Pg.80]

The comparatively inexpensive long-scale thermometer, widely used by students, is usually calibrated for complete immersion of the mercury column in the vapour or liquid. As generally employed for boiling point or melting point determinations, the entire column is neither surrounded by the vapour nor completely immersed in the liquid. The part of the mercury column exposed to the cooler air of the laboratory is obviously not expanded as much as the bulk of the mercury and hence the reading will be lower than the true temperature. The error thus introduced is not appreciable up to about 100°, but it may amount to 3-5° at 200° and 6-10° at 250°. The error due to the column of mercury exposed above the heating bath can be corrected by adding a stem correction, calculated by the formula ... [Pg.72]

The density determination may be carried out at the temperature of the laboratory. The liquid should stand for at least one hour and a thermometer placed either in the liquid (if practicable) or in its immediate vicinity. It is usually better to conduct the measurement at a temperature of 20° or 25° throughout this volume a standard temperature of 20° will be adopted. To determine the density of a liquid at 20°, a clean, corked test-tube containing about 5 ml. of toe liquid is immersed for about three-quarters of its length in a water thermostat at 20° for about 2 hours. An empty test-tube and a shallow beaker (e.g., a Baco beaker) are also supported in the thermostat so that only the rims protrude above the surface of the water the pycnometer is supported by its capillary arms on the rim of the test-tube, and the small crucible is placed in the beaker, which is covered with a clock glass. When the liquid has acquired the temperature of the thermostat, the small crucible is removed, charged with the liquid, the pycnometer rapidly filled and adjusted to the mark. With practice, the whole operation can be completed in about half a minute. The error introduced if the temperature of the laboratory differs by as much as 10° from that of the thermostat does not exceed 1 mg. if the temperature of the laboratory is adjusted so that it does not differ by more than 1-2° from 20°, the error is negligible. The weight of the empty pycnometer and also filled with distilled (preferably conductivity) water at 20° should also be determined. The density of the liquid can then be computed. [Pg.1030]


See other pages where Determinate error Determine is mentioned: [Pg.29]    [Pg.99]    [Pg.224]    [Pg.599]    [Pg.23]    [Pg.370]    [Pg.21]    [Pg.136]    [Pg.172]    [Pg.231]    [Pg.423]    [Pg.96]    [Pg.136]    [Pg.189]    [Pg.282]    [Pg.360]    [Pg.375]    [Pg.438]    [Pg.511]    [Pg.550]    [Pg.590]    [Pg.593]    [Pg.434]    [Pg.473]    [Pg.490]    [Pg.495]    [Pg.54]    [Pg.225]    [Pg.324]    [Pg.85]    [Pg.1081]    [Pg.155]    [Pg.23]    [Pg.26]   