The detector, subject to availability, should match the solute characteristics. UV-visible absorbance detectors are suitable for many solutes except those that are fully saturated. Fluorescence and electrochemical detectors should be considered where high sensitivity is required. [Pg.171]

The collector contains an electrically-heated rubidium salt used as the thermionic source. During the elution of a molecule of a nitrogen compound, the nitrogen is ionized and the collection of these ions produces the signal. The detector is very sensitive but Its efficiency is variable subject to the type of nitrogen molecule, making quantification somewhat delicate. [Pg.79]

The first of them to determine the LMA quantitatively and the second - the LF qualitatively Of course, limit of sensitivity of the LF channel depends on the rope type and on its state very close because the LF are detected by signal pulses exceeding over a noise level. The level is less for new ropes (especially for the locked coil ropes) than for multi-strand ropes used (especially for the ropes corroded). Even if a skilled and experienced operator interprets a record, this cannot exclude possible errors completely because of the evaluation subjectivity. Moreover it takes a lot of time for the interpretation. Some of flaw detector producers understand the problem and are intended to develop new instruments using data processing by a computer [6]. [Pg.335]

In this case, no profound specialised knowledge is required for determination of the type of discontinuities. On the other hand, determination of the nature of damage using a regular flaw detector for manual UT, can be a complicated task for any flaw detection experts, in any case, its solution will require time and qualification of the operator, but. the presence of these conditions will not eliminate the subjective nature of the assessment. [Pg.790]

Instrumental Interface. Gc/fdr instmmentation has developed around two different types of interfacing. The most common is the on-the-fly or flow cell interface in which gc effluent is dkected into a gold-coated cell or light pipe where the sample is subjected to infrared radiation (see Infrared and raman spectroscopy). Infrared transparent windows, usually made of potassium bromide, are fastened to the ends of the flow cell and the radiation is then dkected to a detector having a very fast response-time. In this light pipe type of interface, infrared spectra are generated by ratioing reference scans obtained when only carrier gas is in the cell to sample scans when a gc peak appears. [Pg.402]

Since 1970 the subject of amoiphous semiconductors, in particular silicon, has progressed from obscurity to product commercialisation such as flat-panel hquid crystal displays, linear sensor arrays for facsimile machines, inexpensive solar panels, electrophotography, etc. Many other appHcations are at the developmental stage such as nuclear particle detectors, medical imaging, spatial light modulators for optical computing, and switches in neural networks (1,2). [Pg.357]

Electrochemical detectors sense electroreducible and electrooxidizable compounds at low concentrations. Eor these detectors to work efficiently, the mobile phase (solvent) must be conductive and not subject to electrochemical decomposition. [Pg.110]

Figures 2b and 3 demonstrate that X rays are produced over a range of depth into the sample. The X rays must propagate along a finite path through the specimen to reach the detector, and are subject to photoelectric absorption and scattering, which follows an exponential relation ... Figures 2b and 3 demonstrate that X rays are produced over a range of depth into the sample. The X rays must propagate along a finite path through the specimen to reach the detector, and are subject to photoelectric absorption and scattering, which follows an exponential relation ...
Often, more detailed information is needed on the distribution of a constituent. The technique of X-ray area scanning, or dot mappings can provide a qualirative view of elemental distributions. As the beam is scanned in a raster pattern on the specimen, a cathode ray rube scanned in synchronism is used to display a full white dot whenever the X-ray detector (WDS or EDS) detects an X ray within a certain narrow energy range. The pattern of dots is recorded on film to produce the dot map. Dot maps are subject to the following limitations ... [Pg.187]

Vibration sensors are similar to break-glass detectors but are fixed to walls and doors against violent attack. The stmcture to which they are fitted must not be subject to vibration from external sources, otherwise false alarms may result. [Pg.48]

To the analytical chemist, a standard deviation31 is a logical figure of merit for the comparison of detectors. We shall merely introduce the important subject of counting errors (10.2) here. For present purposes, it suffices to know that these errors are predictable, and that they set a lower limit to the standard deviation in an analytical method that depends upon measuring the intensity of an x-ray beam by an integrating detector. [Pg.65]

Before describing the individual detectors, the subject of detector specifications must be discussed as the performance of the detector strongly influences the accuracy and precision that is realized in the LC analysis. There are a considerable number of detector specifications,... [Pg.157]

The pressure sensitivity of a detector will be one of the factors that determines the long term noise and thus can be very important. It is usually measured as the change in detector output for unit change in sensor-cell pressure. Pressure sensitivity and flow sensitivity are to some extent interdependent, subject to the manner in which the detector functions. The UV detector, the fluorescence detector and the electrical... [Pg.164]

The fringes contrasts are subject to degradation resulting from dissymmetry in the interferometer. The optical fields to be mixed are characterized by a broadband spectrum so that differential dispersion may induce a variation of the differential phase over the spectrum. Detectors are sensitive to the superposition of the different spectral contributions. If differential dispersion shifts the fringes patterns for the different frequency, the global interferogramme is blurred and the contrast decreases. Fig. 5 shows corresponding experimental results. [Pg.295]


See other pages where Subject detector is mentioned: [Pg.54]    [Pg.54]    [Pg.79]    [Pg.272]    [Pg.1432]    [Pg.2825]    [Pg.165]    [Pg.171]    [Pg.63]    [Pg.468]    [Pg.545]    [Pg.129]    [Pg.298]    [Pg.425]    [Pg.437]    [Pg.221]    [Pg.536]    [Pg.244]    [Pg.393]    [Pg.485]    [Pg.108]    [Pg.15]    [Pg.2328]    [Pg.79]    [Pg.224]    [Pg.211]    [Pg.514]    [Pg.76]    [Pg.77]    [Pg.263]    [Pg.663]    [Pg.749]    [Pg.332]    [Pg.383]    [Pg.157]    [Pg.171]    [Pg.27]    [Pg.165]   
See also in sourсe #XX -- [ Pg.907 ]

See also in sourсe #XX -- [ Pg.353 ]