Lithium-drifted detectors

The energy-dispersive (EDX) solid state detector (SSD, Figs 4.6, 4.7) is made of lithium-drifted Si crystal (Si(Li)). Between a thin p-type and an n-type layer lies a high-resistivity Si crystal of centimeter dimensions. The front and end planes of the crystal are coated with Au and serve as electrodes. The crystal, cooled to 77 K by liquid nitrogen, represents a p-i-n diode (Fig. 4.7). An incident X-ray photon with... [Pg.185]

Instrumentation. Traditional methods of alpha and beta spectrometry instrumentation have changed little over the past decade. Alpha spectrometric methods typically rely on semi-conductor or lithium-drifted silicon detectors (Si(Li)), or more historically gridded ion chambers, and these detection systems are still widely used in various types of uranium-series nuclide measurement for health, environmental, and... [Pg.30]

Potter, G. D., McIntyre, D. R. and Pomeroy, D. (1967). Transport of fallout radionuclides in the grass-to-milk food chain studied with a germanium lithium-drifted detector, page 597 in Symposium on Radioecology, USAEC Report No. CONF-670503, Nelson, D. J. and Evans, F. C., Eds. (National Technical Information Service, Springfield, Virginia). [Pg.95]

The introduction of high-resolution, high-efficiency /-ray detectors composed of lithium-drifted germanium crystals has revolutionised /-measurement techniques. Thus, /-spectrometry allows the rapid measurement of relatively low-activity samples without complex analytical preparations. A technique described by Michel et al. [25] uses Ge(Li) /-ray detectors for the simultaneous measurements of 228radium and 226radium in natural waters. This method simplifies the analytical procedures and reduces the labour while improving the precision, accuracy, and detection limits. [Pg.347]

Chassery et al. [97] studied the 87Sr/86Br composition in marine sediments, observing excellent agreement between results obtained by ICP-MS and thermal ionisation mass spectrometry. Low level a-spectrometry with lithium drifted germanium detectors has been used to determine 90strontium in seawater [59]. [Pg.357]

The alternative approach to detection and analysis incorporates a solid state detector and a multichannel pulse height analysis system. The crystals used are of silicon (of the highly pure intrinsic type), or the lithium drift principle (p. 463 etseq.) is utilized. All emitted radiations are presented to the detector simultaneously and a spectrum is generated from an electronic analysis of the mixture of voltage pulses produced. Chapter 10 contains a more detailed account of pulse height analysis and solid state detectors. Production of an X-ray spectrum in this way is sometimes known as energy dispersive analysis ofX-rays (EDAX) and where an electron microscope is employed as SEM-EDAX. [Pg.347]

Lithium dichromate, molecular formula, properties, and uses, 6 562t Lithium diisopropylamide (LDA), 15 148 Lithium-drifted silicon [Si(Li)] detector, 26 434... [Pg.531]

As discussed above, the measurement of characteristic y rays is very similar to the methods used in EDXRF. Early studies used a scintillation counter, typically a crystal of sodium iodide containing a small amount of thallium (Tite 1972). y ray absorption by these counters produces visible light, which is converted into an electrical pulse using a photosensitive detector. More recently semiconductor detectors have been used, either a lithium drifted germanium crystal, or, more typically, a pure ( intrinsic )... [Pg.129]

Radionuclidic analyses are performed with either a lithium-drifted germanium or intrinsic germanium detector. The assay for Sr-82 is based upon its 777 keV photon of 13.6% abundance. Strontium-85, which is often present in amounts comparable to that of Sr-82, is assayed by its 514 keV photopeak, which must be resolved from prominent 511 keV annihilation radiation by a curve stripping procedure (12). [Pg.143]

Lithium-Drifted Germanium Detectors. Two kinds of planar Ge(Li) diodes were fabricated in our Laboratory for the spectrometer (I). The chief consideration was maximum cross section with a resolution of less than 3 k.e.v. at 60Co FWHM (full width half maximum). The available single-crystal germanium material dictated the shape of the detector. The first detector was fabricated from a 15-cm. long Sylvania ingot with a trapezoidal cross section its finished dimensions were 6 cm. X 3 cm. X 1 cm. Our second detector was fabricated from circular Hoboken stock (NPC Metal and Chemical Co., Los Angeles) its finished dimensions were 2.8 cm. diameter X 1.2 cm. thick. [Pg.214]

Germanium metal is also used in specially prepared Ge single crystals for y-ray detectors (54). Both the older lithium-drifted detectors and the newer intrinsic detectors, which do not have to be stored in liquid nitrogen, do an excellent job of spectral analysis of y-radiation and are important analytical tools. Even more sensitive Ge detectors have been made using isotopically enriched Ge crystals. Most of these have been made from enriched 7<5Ge and have been used in neutrino studies (55—57). [Pg.281]

Detectors include (1) Geiger-Mueller tube, (2) ionization chambers, (3) scintillation counters, (4) proportional counter, (5) electron-multiplier tubes, and (G) nondispersive detectors using cooled lithium-drifted Si detectors, See Fig. 3... [Pg.1759]

The basic characteristics of EDS detectors, their limitations and methods for improvement of performance have been documented by a number of workers r9.101. Lithium-drifted Si and high-purity Ge are the two types of solid-state devices currently used in EDS detectors on AEMs. A compilation of EDS detection principles and characteristics, including less commonly used devices, such as Hgl detectors, is given by Heinrich et al. riOl. [Pg.39]


See other pages where Lithium-drifted detectors is mentioned: [Pg.254]    [Pg.5191]    [Pg.5192]    [Pg.254]    [Pg.5191]    [Pg.5192]    [Pg.11]    [Pg.125]    [Pg.358]    [Pg.199]    [Pg.371]    [Pg.99]    [Pg.289]    [Pg.149]    [Pg.370]    [Pg.464]    [Pg.53]    [Pg.103]    [Pg.131]    [Pg.519]    [Pg.121]    [Pg.108]    [Pg.210]    [Pg.211]    [Pg.215]    [Pg.132]    [Pg.286]    [Pg.556]    [Pg.558]    [Pg.160]    [Pg.108]    [Pg.355]    [Pg.74]    [Pg.126]    [Pg.464]    [Pg.60]   