Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Detection solvent chromatography

Hydrocarbon Anomalies in Soils Soil samples were collected at 200 to 500 m intervals over the Lisbon and Lightning Draw fields and analyzed for thermally desorbed Ci to C12 alkanes by Flame Ionization Detection Gas Chromatography (GC-FID) and solvent-extractable Ce to C36 aromatics by UV-fluorescence spectrophotometry. [Pg.390]

Note that in liquid phase chromatography there are no detectors that are both sensitive and universal, that is, which respond linearly to solute concentration regardless of its chemical nature. In fact, the refractometer detects all solutes but it is not very sensitive its response depends evidently on the difference in refractive indices between solvent and solute whereas absorption and UV fluorescence methods respond only to aromatics, an advantage in numerous applications. Unfortunately, their coefficient of response (in ultraviolet, absorptivity is the term used) is highly variable among individual components. [Pg.27]

Liquid phase chromatography can use a supercritical fluid as an eluent. The solvent evaporates on leaving the column and allows detection by FID. At present, there are few instances in the petroleum industry using the supercritical fluid technique. [Pg.27]

Analytical Techniques. Sorbic acid and potassium sorbate are assayed titrimetricaHy (51). The quantitative analysis of sorbic acid in food or beverages, which may require solvent extraction or steam distillation (52,53), employs various techniques. The two classical methods are both spectrophotometric (54—56). In the ultraviolet method, the prepared sample is acidified and the sorbic acid is measured at 250 260 nm. In the colorimetric method, the sorbic acid in the prepared sample is oxidized and then reacts with thiobarbituric acid the complex is measured at - 530 nm. Chromatographic techniques are also used for the analysis of sorbic acid. High pressure Hquid chromatography with ultraviolet detection is used to separate and quantify sorbic acid from other ultraviolet-absorbing species (57—59). Sorbic acid in food extracts is deterrnined by gas chromatography with flame ionization detection (60—62). [Pg.284]

Polymerization-grade chloroprene is typically at least 99.5% pure, excluding inert solvents that may be present. It must be substantially free of peroxides, polymer [9010-98-4], and inhibitors. A low, controlled concentration of inhibitor is sometimes specified. It must also be free of impurities that are acidic or that will generate additional acidity during emulsion polymerization. Typical impurities are 1-chlorobutadiene [627-22-5] and traces of chlorobutenes (from dehydrochlorination of dichlorobutanes produced from butenes in butadiene [106-99-0]), 3,4-dichlorobutene [760-23-6], and dimers of both chloroprene and butadiene. Gas chromatography is used for analysis of volatile impurities. Dissolved polymer can be detected by turbidity after precipitation with alcohol or determined gravimetrically. Inhibitors and dimers can interfere with quantitative determination of polymer either by precipitation or evaporation if significant amounts are present. [Pg.39]

The method of detecting dimethylterephthalate (DMTP), dibuthyl-phthalate (DBP) and diocthylphthalate (DOP) in aqueous extract is based on their extraction with an organic solvent (hexane) and subsequent concentration using gas-liquid chromatography and an electron-absorbing detector. The detection limit is 0.05 mg/dirf for DMTP and DBP, and 0,01 mg/dm for DOP. [Pg.389]

Electrostatic and adsorption effects conspire to make aqueous GPC more likely to be nonideal than organic solvent GPC. Thus, universal calibration is often not obeyed in aqueous systems. Elence, it is much more critical that the standard chosen for calibration share with the polymer being analyzed chemical characteristics that affect these interactions. Because standards that meet this criterion are often not available, it is prudent to include in each analysis set a sample of a secondary standard of the same composition and molecular weight as the sample. Thus, changes in the chromatography of the analyte relative to the standards will be detected. [Pg.557]

Figure 2.12 Schematic representation of an on-line SPE-GC system consisting of three switching valves (VI-V3), two pumps (a solvent-delivery unit (SDU) pump and a syringe pump) and a GC system equipped with a solvent-vapour exit (SVE), an MS instrument detector, a retention gap, a retaining precolumn and an analytical column. Reprinted from Journal of Chromatography, AIIS, A. J. H. Eouter et al, Analysis of microcontaminants in aqueous samples hy fully automated on-line solid-phase extraction-gas chromatography-mass selective detection , pp. 67-83, copyright 1996, with permission from Elsevier Science. Figure 2.12 Schematic representation of an on-line SPE-GC system consisting of three switching valves (VI-V3), two pumps (a solvent-delivery unit (SDU) pump and a syringe pump) and a GC system equipped with a solvent-vapour exit (SVE), an MS instrument detector, a retention gap, a retaining precolumn and an analytical column. Reprinted from Journal of Chromatography, AIIS, A. J. H. Eouter et al, Analysis of microcontaminants in aqueous samples hy fully automated on-line solid-phase extraction-gas chromatography-mass selective detection , pp. 67-83, copyright 1996, with permission from Elsevier Science.
An on-line supercritical fluid chromatography-capillary gas chromatography (SFC-GC) technique has been demonstrated for the direct transfer of SFC fractions from a packed column SFC system to a GC system. This technique has been applied in the analysis of industrial samples such as aviation fuel (24). This type of coupled technique is sometimes more advantageous than the traditional LC-GC coupled technique since SFC is compatible with GC, because most supercritical fluids decompress into gases at GC conditions and are not detected by flame-ionization detection. The use of solvent evaporation techniques are not necessary. SFC, in the same way as LC, can be used to preseparate a sample into classes of compounds where the individual components can then be analyzed and quantified by GC. The supercritical fluid sample effluent is decompressed through a restrictor directly into a capillary GC injection port. In addition, this technique allows selective or multi-step heart-cutting of various sample peaks as they elute from the supercritical fluid... [Pg.325]

Figure 13.2 MDGC-ECD chromatograms of PCB fractions from sediment samples, demonstrating the separation of the enantiomers of (a) PCB 95, (b) PCB 132, and (c) PCB 149 non-labelled peaks were not identified. Reprinted from Journal of Chromatography, A 723, A. Glausch et al, Enantioselective analysis of chiral polyclilorinated biphenyls in sediment samples by multidimensional gas cliromatography-electi on-capture detection after steam distillation-solvent exti action and sulfur removal , pp. 399-404, copyright 1996, with permission from Elsevier Science. Figure 13.2 MDGC-ECD chromatograms of PCB fractions from sediment samples, demonstrating the separation of the enantiomers of (a) PCB 95, (b) PCB 132, and (c) PCB 149 non-labelled peaks were not identified. Reprinted from Journal of Chromatography, A 723, A. Glausch et al, Enantioselective analysis of chiral polyclilorinated biphenyls in sediment samples by multidimensional gas cliromatography-electi on-capture detection after steam distillation-solvent exti action and sulfur removal , pp. 399-404, copyright 1996, with permission from Elsevier Science.
The residue is triturated with methanol to afford a crystalline solid. This material contains no detectable amount of starting material by paperstrip chromatography but shows two UV absorbing spots near the solvent front (methanol-formamide 2 1 vs benzene-n-hexane 1 1). An aliquot is recrystallized three times from a mixture of benzene and n-hexane to give 17a,20,20,21-bis(methylenedioxy)-11(3-hydroxy-6,16a-dimethyl-4,6-pregnadiene-3-one which is used in the subsequent step of the synthesis without further purification. [Pg.391]


See other pages where Detection solvent chromatography is mentioned: [Pg.225]    [Pg.116]    [Pg.319]    [Pg.184]    [Pg.172]    [Pg.220]    [Pg.183]    [Pg.647]    [Pg.110]    [Pg.597]    [Pg.693]    [Pg.45]    [Pg.54]    [Pg.219]    [Pg.276]    [Pg.354]    [Pg.446]    [Pg.181]    [Pg.392]    [Pg.178]    [Pg.109]    [Pg.116]    [Pg.157]    [Pg.378]    [Pg.24]    [Pg.61]    [Pg.64]    [Pg.374]    [Pg.210]    [Pg.82]    [Pg.245]    [Pg.238]    [Pg.284]    [Pg.321]    [Pg.369]    [Pg.411]    [Pg.142]    [Pg.36]    [Pg.79]   
See also in sourсe #XX -- [ Pg.172 ]




SEARCH



Chromatography detection

© 2024 chempedia.info