Inductively coupled plasma (icp) emission, direct current plasma (dcp), and inductively coupled plasma mass spectrometry (icp/ms) have taken over as the methods of choice for the simultaneous detection of metallic impurities in hafnium and hafnium compounds (29,30). [Pg.443]

The complex of the following destmctive and nondestmctive analytical methods was used for studying the composition of sponges inductively coupled plasma mass-spectrometry (ICP-MS), X-ray fluorescence (XRF), electron probe microanalysis (EPMA), and atomic absorption spectrometry (AAS). Techniques of sample preparation were developed for each method and their metrological characteristics were defined. Relative standard deviations for all the elements did not exceed 0.25 within detection limit. The accuracy of techniques elaborated was checked with the method of additions and control methods of analysis. [Pg.223]

Inductively coupled plasma-mass spectrometry (ICP-MS) is a multielement analytical method with detection limits which are, for many trace elements, including the rare earth elements, better than those of most conventional techniques. With increasing availability of ICP-MS instalments in geological laboratories this method has been established as the most prominent technique for the determination of a large number of minor and trace elements in geological samples. [Pg.454]

Inductively coupled plasma mass spectrometry was applied to the analysis of six organotin compounds (chlorides of dimethyl-, dibutyl-, trimethyl-, tributyl-, diphenyl-, and triphenyltin). Detection hmits for the six organotins ranged from 24 to 51 pg as tin the dynamic range was over lO, from 1 pg/1 to 10 mg/1 (Inoue Kawabata, 1993). [Pg.7]

In order to relate material properties with plasma properties, several plasma diagnostic techniques are used. The main techniques for the characterization of silane-hydrogen deposition plasmas are optical spectroscopy, electrostatic probes, mass spectrometry, and ellipsometry [117, 286]. Optical emission spectroscopy (OES) is a noninvasive technique and has been developed for identification of Si, SiH, Si+, and species in the plasma. Active spectroscopy, such as laser induced fluorescence (LIF), also allows for the detection of radicals in the plasma. Mass spectrometry enables the study of ion and radical chemistry in the discharge, either ex situ or in situ. The Langmuir probe technique is simple and very suitable for measuring plasma characteristics in nonreactive plasmas. In case of silane plasma it can be used, but it is difficult. Ellipsometry is used to follow the deposition process in situ. [Pg.79]

In modern times, most analyses are performed on an analytical instrument for, e.g., gas chromatography (GC), high-performance liquid chromatography (HPLC), ultra-violet/visible (UV) or infrared (IR) spectrophotometry, atomic absorption spectrometry, inductively coupled plasma mass spectrometry (ICP-MS), mass spectrometry. Each of these instruments has a limitation on the amount of an analyte that they can detect. This limitation can be expressed as the IDL, which may be defined as the smallest amount of an analyte that can be reliably detected or differentiated from the background on an instrument. [Pg.63]

In contrast to thermal ionization methods, where the tracer added must be of the same element as the analyte, tracers of different elemental composition but similar ionization efficiency can be utilized for inductively coupled plasma mass spectrometry (ICPMS) analysis. Hence, for ICPMS work, uranium can be added to thorium or radium samples as a way of correcting for instrumental mass bias (e g., Luo et al. 1997 Stirling et al. 2001 Pietruszka et al. 2002). The only drawback of this approach is that small inter-element (e g., U vs. Th) biases may be present during ionization or detection that need to be considered and evaluated (e.g., Pietruszka et al. 2002). [Pg.27]

This chapter also deals in particular with chromatographic detection by atomic plasma spectrometry and plasma mass spectrometry (AED, MIP, ICP). With the application of such detectors, metal-specific signals can be obtained - thus the information content of a separation increases significantly. The major objectives of interfaced chromatography-atomic plasma source emission spectrometry (C-APES) are ... [Pg.455]

R. Trones, Development of Packed Capillary High Temperature Liquid Chromatography Utilizing Light Scattering and Inductively Coupled Plasma Mass Spectrometry Detection, PhD. Thesis, University of Oslo (1999). [Pg.749]

ICP-MS (inductively coupled plasma mass spectrometry) is frequently used for determining ultratrace amounts of technetium [9]. In spite of the high cost of the equipment, this detection method is far superior to other radiometric methods as regards sensitivity. When a double focussing high-resolution system is used (HR-ICP-MS) and an ultrasonic nebulizer is introduced [10], the detection limit is in the order 0.002 mBq. The ICP-MS method has been successfully applied to the determination of environmental "Tc as well as to other long-lived radionuclides of neptunium and plutonium in the environment. [Pg.25]

Debrak and Denoyer [484] determined mercury at the ppt level in seawater by the addition of tin chloride to produce hydrogen vapour, and trapping on gold-platinum gauze, prior to heating and detection of the mercury released by inductively coupled plasma mass spectrometry. [Pg.201]

Techniques for analysis of different mercury species in biological samples and abiotic materials include atomic absorption, cold vapor atomic fluorescence spectrometry, gas-liquid chromatography with electron capture detection, and inductively coupled plasma mass spectrometry (Lansens etal. 1991 Schintu etal. 1992 Porcella etal. 1995). Methylmercury concentrations in marine biological tissues are detected at concentrations as low as 10 pg Hg/kg tissue using graphite furnace sample preparation techniques and atomic absorption spectrometry (Schintu et al. 1992). [Pg.355]

The primary and immediate need is for a trace metal reference material, but a certified reference material would provide even greater benefits. A technique based on isotope dilution with detection by inductively-coupled plasma mass spectrometry (ICP-MS) (Wu and Boyle, 1998) most clearly meets the traceability criteria required for a certified reference material. Although useful for iron and several other metals, isotope dilution is not possible for monoisotopic elements like cobalt, so other techniques must also be used. Indeed, it is advisable that several techniques be used to certify a trace metal reference material. [Pg.49]

Soil samples were wet sieved into (a) 2-4 mm, (b) 1-2 mm, (c) 0.5-1 mm, (d) 250-500 i m, (e) 125-250 am, (f) 63-125 j,m and (g) <63 j.m fractions. A ferruginous/magnetic fraction (m) was also prepared from the 2-4 mm fraction. Soil fractions were crushed, digested with HNO3/HCI/HF/HCIO4 and then analysed by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) for Al, Ca, Cu, Fe, K, Mn, Na, P, S and Zn. Inductively Coupled Plasma Mass Spectrometry (ICP-MS) was used to determine Ag, As, Cd, Pb and Sb because of the lower detection limits by this method. The mineralogy of selected samples was determined by qualitative X-ray diffractometry. [Pg.88]

Cations were determined by high-resolution inductively coupled plasma-mass spectrometry (HR-ICPMS), relatively new analytical instrumentation with a large dynamic range and detection limits (DLs) in the low (1-50) parts per trillion (ppt) for most elements. The exceedingly low DLs allow for recognition of elemental variations that are not possible with traditional analytical methods for water. [Pg.365]

In 1C, the election-detection mode is the one based on conductivity measurements of solutions in which the ionic load of the eluent is low, either due to the use of eluents of low specific conductivity, or due to the chemical suppression of the eluent conductivity achieved by proper devices (see further). Nevertheless, there are applications in which this kind of detection is not applicable, e.g., for species with low specific conductivity or for species (metals) that can precipitate during the classical detection with suppression. Among the techniques that can be used as an alternative to conductometric detection, spectrophotometry, amperometry, and spectroscopy (atomic absorption, AA, atomic emission, AE) or spectrometry (inductively coupled plasma-mass spectrometry, ICP-MS, and MS) are those most widely used. Hence, the wide number of techniques available, together with the improvement of stationary phase technology, makes it possible to widen the spectrum of substances analyzable by 1C and to achieve extremely low detection limits. [Pg.406]

Gautier C., Bourgeois M., Isnard H., Nonell A., Stadeknann G. Goutelard E. Development of cadmium/silver/palladium separation by ion chromatography with quad-mpole inductively coupled plasma mass spectrometry detection for off-line cadmium isotopic measurements. Journal of Chromatography A 2011 1218 (31)5241-5247. [Pg.29]


See other pages where Detection plasma mass spectrometry is mentioned: [Pg.549]    [Pg.134]    [Pg.323]    [Pg.530]    [Pg.634]    [Pg.7]    [Pg.39]    [Pg.288]    [Pg.130]    [Pg.443]    [Pg.231]    [Pg.629]    [Pg.295]    [Pg.435]    [Pg.435]    [Pg.237]    [Pg.31]    [Pg.58]    [Pg.195]    [Pg.327]    [Pg.20]    [Pg.621]    [Pg.1550]    [Pg.152]    [Pg.215]    [Pg.241]    [Pg.334]    [Pg.340]    [Pg.347]    [Pg.353]    [Pg.355]    [Pg.511]   