Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Data analysis, simplified

Design Simplified elicitation process. - Design - Data collection - Data analysis Simplified plan for data analysis. [Pg.1446]

Based on the bench-scale data, two coal-to-acetylene processes were taken to the pilot-plant level. These were the AVCO and Hbls arc-coal processes. The Avco process development centered on identifying fundamental process relationships (29). Preliminary data analysis was simplified by first combining two of three independent variables, power and gas flow, into a single enthalpy term. The variation of the important criteria, specific energy requirements (SER), concentration, and yield with enthalpy are indicated in Figure 12. As the plots show, minimum SER is achieved at an enthalpy of about 5300 kW/(m /s) (2.5 kW/cfm), whereas maximum acetylene concentrations and yield are obtained at about 7400 kW/(m /s) (3.5 kW/cfm). An operating enthalpy between these two values should, therefore, be optimum. Based on the results of this work and the need to demonstrate the process at... [Pg.391]

Cyclodextrin-modified solvent extraction has been used to extract several PAHs from ether to an aqueous phase. Data evaluation shows that the degree of extraction is related to the size of the potential guest molecule and that the method successfully separates simple binary mixtures in which one component does not complex strongly with CDx. The most useful application of cyclodextrin-modified solvent extraction is for the simplification of complex mixtures. The combined use of CDx modifier and data-analysis techniques may simplify the qualitative analysis of PAH mixtures. [Pg.178]

Owing to the symmetry property of an optical dipole transition, the data analysis for a photodissociation study is greatly simplified. The center-of-mass differential cross-section for a single-photon, dissociative process can be expressed as38,39... [Pg.12]

A definition of Chemometrics is a little trickier of come by. The term was originally coined by Kowalski, but nowadays many Chemometricians use the definition by Massart [4], On the other hand, one compilation presents nine different definitions for Chemometrics [5, 6] (including What Chemometricians do , a definition that apparently was suggested only HALF humorously ). But our goal here is not to get into the argument over the definition of the term, so for our current purposes, it is convenient to consider a perhaps somewhat simplified definition of Chemometrics as meaning multivariate methods of data analysis applied to data of chemical interest . [Pg.471]

The use of PIR compounds to study protein interactions is a significant advance over the use of standard homobifunctional crosslinkers. The unique design of the PIR reagent facilitates deconvolution of putative protein interaction complexes through a simplified mass spec analysis. The software can ignore all irrelevant peak data and just focus analysis on the two labeled peptide peaks, which accompany the reporter signal of appropriate mass. This greatly simplifies the bioinformatics of data analysis and provides definitive conformation of protein-protein crosslinks. [Pg.1015]

Fourier analysis (Bloomfield, 1976) is most frequently a univariate method used for either simplifying data (which is the basis for its inclusion in this chapter) or for modeling. It can, however, also be a multivariate technique for data analysis. [Pg.949]

The Aspen Properties implementation of the NRLT-SAC method is available as a template. aprbkp file to license holders of Aspen Properties or Aspen Plus release 12.1 or above, by contacting Aspen s support centre or regional sales offices. The template is distributed with an Excel interface to simplify the data regression process and is suitable for non-expert users of Aspen Properties. Numerous Excel templates are available for data analysis and design calculations, based on the NRTL-SAC model. [Pg.59]

The potential of modern chemical instrumentation to detect and measure the conposition of coirplex mixtures has made it necessary to consider the use of methods of multivariable data analysis in the overall evaluation of environmental measurements. In a number of instances, the category (chemical class) of the compound that has given rise to a series of signals may be known but the specific entity responsible for a given signal may not be. This is true, for example, for the polychlorinated biphenyls (PCB s) in which the clean-up procedure and use of specific detectors eliminates most possibilities except PCB s. Such hierarchical procedures simplify the problem somewhat but it is still advantageous to apply data reduction methods during the course of the interpretation process. [Pg.243]

Application of the dual mode concept to gas diffusion in glassy polymers was originally subject to the limitation that DT2 = OinEq. (6) ( total immobilization model )6-Later this simplifying assumption was shown to be unnecessary, provided that suitable methods of data analysis were used 52). Physically, the assumption DX2 = 0 is unrealistic, although it is expected that DT2 < DX1 52). Hence, this more general approach is often referred to as the partial immobilization model . [Pg.103]

Protein microarrays have many potential applications in high-throughput analysis of protein function. However, simple, reproducible, and robust methods for array fabrication are required. Here we discuss the background to different routes to array fabrication and describe in detail one approach in which the purification and immobilization procedures are combined into a single step, dramatically simplifying the array fabrication process. We illustrate this approach by reference to the creation of an array of p53 variants, and discuss methods for assay and data analysis on such arrays. [Pg.197]

The rather complex issue of chemical kinetics has been discussed in a quantitative way, in order to stress out two main ideas, namely, the necessity of resorting to simplified kinetic models and the need of adequate methods of data analysis to estimate the kinetic parameters. These results introduce Chap. 3, in which basic concepts and up-to-date methods of identification of kinetic parameters are presented. [Pg.37]

Often the data analysis requires multiplication by some number B such as Avo-gadro s number, which is typically known to much higher accuracy than any of the measured data. In that case, the rule for multiplication above simplifies immediately to AC/C = A A/A—the fractional error after multiplication by a constant is unchanged. [Pg.73]

Wilson, C.J. et al. 2006. Identification of a small molecule that induces mitotic arrest using a simplified high-content screening assay and data analysis method. J. Biomol. Screen. 11, 21-28. [Pg.155]

Some topics have been omitted from this review. This holds for the structure and function of metal sites in metalloproteins and metalloenzymes in relation to enzymatic catalysis, for which the reader is referred to Cramer and Hodgson (68) and Doniach et al. (80). Also, chemisorption studies and the structure of adsorbate-covered surfaces are not considered in this review, which deals with XAES in transmission, thus characterizing bulk material. It is noted that even in the case of chemisorbed atoms XANES data analysis requires physically the definition of clusters of considerable size. On the other hand, the analysis is simplified for adsorbed molecules. Very pronounced near-edge effects (usually obtained by electron-stimulated Auger measurements) are observed for low-Z-atom(C, N, O, F>containing chemisorbed... [Pg.258]

Capillary gas chromatography (GC) was used to determine the aminopropyldisiloxane concentration. An 11-m column (0.2-mm internal diameter) coated with a dime thy Isiloxane stationary phase was used. Temperature-programming techniques and a flame ionization detector were used. Tetradecane was used as an internal standard. Details of the chromatographic conditions have been reported earlier (8). A Varian Vista 402 data station simplified the calibration and analysis for both the HPLC and GC methods. [Pg.148]

The application of eqn (2) assumes that I v" is linearly proportional to This is valid in the limit of no radiation trapping and no optical pumping of the molecular sample. Under our experimental conditions, the former poses no problem, whereas the latter requires consideration because of the high laser intensity used. Indeed, we observe a departure from linearity, which decreases as the laser intensity is reduced. Data, such as that shown in fig. 3-6, are taken with the laser intensity attenuated by typically fourfold, at which condition the deviation from linearity is 15 %. To simplify data analysis, the same laser intensity (to within 20 %) is used for all scans, and only linear corrections to are made for variation in laser intensity. [Pg.134]


See other pages where Data analysis, simplified is mentioned: [Pg.136]    [Pg.767]    [Pg.229]    [Pg.618]    [Pg.389]    [Pg.138]    [Pg.436]    [Pg.194]    [Pg.53]    [Pg.49]    [Pg.131]    [Pg.32]    [Pg.80]    [Pg.302]    [Pg.168]    [Pg.421]    [Pg.257]    [Pg.177]    [Pg.185]    [Pg.223]    [Pg.268]    [Pg.205]    [Pg.767]    [Pg.71]    [Pg.167]    [Pg.824]    [Pg.124]    [Pg.208]    [Pg.18]    [Pg.112]    [Pg.308]    [Pg.69]   
See also in sourсe #XX -- [ Pg.319 , Pg.320 ]




SEARCH



Simplified

Simplify

© 2024 chempedia.info