Damper mechanism

Provide damper mechanical position stop to prevent complete closure of damper Eliminate ignition sources within the ductwork Use bonding and grounding Eliminate flammables or combustible by material substitution Use inert atmosphere... [Pg.50]

Provide damper mechanical position stop to prevent complete closure of damper... [Pg.70]

Mechanical devices need careful installation to ensure that there is no distortion of the parts. This is especially the case with damper mechanisms, which need maintenance and periodic inspection to ensure they are working correctly... [Pg.329]

Centrifugal fans are usually of sheet metal construction, with the most popular protective coating being hot-dip galvanization. Damper mechanisms are also available to facilitate capacity control of the cooling tower. [Pg.330]

Air control louvers or dampers, popular in the past for air flow control, are used primarily for only very low scale air flow control. Louvers are used in many winterized heat exchangers in extremely low ambient temperature locations to retain and recirculate warm air in completely enclosed heat exchangers, sometimes in very compHcated control schemes. The use of louvers on the discharge side of a fan to control air flow is inefficient and creates mechanical problems in the louvers because of the turbulence. A fan is a constant volume device, thus use of louvers to control flow is equivalent to... [Pg.111]

Airflow rate controller Any mechanical, pneumatic, or electrical device that controls the air flow rare into Or out of a space by increasing or decreasing the flow resistance. See Dampers and Valve. [Pg.1412]

Electric control An electrical device that controls some mechanical function, such as a damper control. [Pg.1433]

Fire and smoke damper. A device used to isolate one area of a building from fire or smoke in another, or one part of a duct run from fire or smoke in another. The device is mechanically or electrically operated in case of fire. [Pg.1441]

Mechanism An arrangement that allows rotary movement to be converted to linear movement or vice versa. A linkage for dampers, etc. [Pg.1458]

To save energy, many HVAC systems employ a mechanism for regulating the flow of outdoor air called an economizer cycle. An economizer cycle takes advantage of milder outdoor conditions to increase the outside air intake and in the process reduces the cooling load on the system. Controlling the rate of flow of outdoor air appears simple, in theory, but often works poorly m practice. The small pressure drop required to control the flow rate of outdoor air is rarely controlled and monitored. Quite often, the damper system used to regulate the airflow is nonfunctional, disconnected from the damper actuators, or casually adjusted by building operators (Institute of Medicine, 2000). [Pg.54]

Liquid seal drums Emergency vent streams are usually passed through a liquid seal, commonly water, before going to the flare stack. The liquid seal drum is usually located downstream of the knockout drum, and some vendors designs include them in the base of the flare stack. A liquid seal drum is used to maintain a positive pressure in the vent header system and upstream system. It also reduces the possibility of flame flashbacks, caused when air is inadvertently introduced into the flare system and the flame front pulls down into the stack it also acts as a mechanical damper on any explosive shock wave in the flare stack. Figure 23-58 is a schematic of a typical flare stack liquid seal drum, designed per API RP 521 criteria. [Pg.91]

In practice, the efficiency of a fired heater is controlled by monitoring the oxygen concentration in the combustion products in addition to the stack gas temperature. Dampers are used to manipulate the air supply. By tying the measuring instruments into a feedback loop with the mechanical equipment, optimization of operations can take place in real time to account for variations in the fuel flow rate or heating value. [Pg.418]

Rebuffs from the official system of artistic unions and competitions soon put a damper on the optimism that had been awakened in Kosmatschof by the success of his sculpture in Ashkhabad - for example, when he was not permitted to realize his designs for large-scale sculptures outside the new Soviet embassy in Mauritania, which he had developed in porcelain. Kosmatschof had created a series of studies for this work, which he was able to produce in a ceramics studio man-sized sculptures or groups of sculptures which decline mechanic/ organic themes in a surrealistically schooled vocabulary of forms and which in today s canon can be placed, in retrospect, between Oldenburg, Luginbuhl and New Realism. Nevertheless, the... [Pg.20]

HVAC blast dampers are devices with mechanical elements which close within milliseconds of the blast wave arrival. Blast dampers are available which will remain closed or which will reopen after pressures return to normal. Blast dampers arc furnished in frames that require attachment to properly designed structural elements. [Pg.201]

In a previous paper (16) the hardware design of the SEC/Viscometer system used in this work has been described. The effects of operational variables, e.g. pump pulsations, flow rate and flow irregularities on the performance of the viscometer and the enhancement of the signal-to-noise ratio by using mechanical dampers also has been described. Our current work has focused on the development, implementation and application of automated data... [Pg.131]

The regulation dampers — air flow (blow, return, or exhaust) by room or by intake or return opening — must be manual with mechanical locking (minimal looseness allowed) located in the ducts. The general dampers, or those for most important sections, must be similar to the dampers for air handling unit a suitable model should be selected. [Pg.48]

In all cases, to achieve a proper regulation of the flow, a pulsation damper is used. It operates on the principle of a mechanical ballast or can be electronically controlled. The simplest mechanical ballasting device is a coil with a low cross-section, several metres in length, placed between the pump and the injector. Under the influence of a wave of solvent, the tube uncoils slightly which increases its internal volume and dampens the variation in pressure. [Pg.48]

The term dynamic test is used here to describe the type of mechanical test in which the rubber is subjected to a cyclic deformation pattern from which the stress strain behaviour is calculated. It does not include cyclic tests in which the main objective is to fatigue the rubber, as these are considered in Chapter 12. Dynamic properties are important in a large number of engineering applications of rubber including springs and dampers and are generally much more useful from a design point of view than the results of many of the simpler static tests considered in Chapter 8. Nevertheless, they are even today very much less used than the "static" tests, principally because of the increased complexity and apparatus cost. [Pg.173]

The operation of proximity sensors can be based on a wide range of principles, including capacitance, induction, Hall and magnetic effects variable reluctance, linear variable differential transformer (LVDT), variable resistor mechanical and electromechanical limit switches optical, photoelectric, or fiber-optic sensors laser-based distance, dimension, or thickness sensors air gap sensors ultrasonic and displacement transducers. Their detection ranges vary from micrometers to meters, and their applications include the measurement of position, displacement, proximity, or operational limits in controlling moving components of valves and dampers. Either linear or angular position can be measured ... [Pg.488]

An independent contractor responsible to the construction manager or owner should do testing and balancing (TAB) of mechanical systems. All start-up should be complete and initial valve or damper settings made (and recorded) by the subcontractor before testing and balancing begins. The TAB contractor should not have to repair equipment or troubleshoot inoperative equipment but rather only adjust and verify performance of equipment. [Pg.206]

Constant flow reciprocating pumps are now the most widely used type (figure 4.26a), but because their mechanical action inherently produces a pulsating delivery of the mobile phase the flow must be smoothed so as to eliminate the pulsations. This can be achieved in several ways, the simplest being the incorporation of a pulse damper in the flow to the column. One... [Pg.114]


See other pages where Damper mechanism is mentioned: [Pg.177]    [Pg.177]    [Pg.92]    [Pg.104]    [Pg.104]    [Pg.1601]    [Pg.360]    [Pg.361]    [Pg.361]    [Pg.219]    [Pg.79]    [Pg.54]    [Pg.303]    [Pg.678]    [Pg.778]    [Pg.634]    [Pg.40]    [Pg.120]    [Pg.47]    [Pg.243]    [Pg.67]    [Pg.576]    [Pg.120]    [Pg.171]    [Pg.360]    [Pg.120]    [Pg.424]    [Pg.133]    [Pg.79]   