Control valves fire, explosion protection

The next step is to apply a number of loss control credit factors such as process control (emergency power, cooling, explosion control, emergency shutdown, computer control, inert gas, operating procedures, reactive chemical reviews), material isolation (remote control valves, blowdown, drainage, interlocks) and fire protection (leak detection, buried tanks, fire water supply, sprinkler systems, water curtains, foam, cable protection). The credit factors are combined and appHed to the fire and explosion index value to result in a net index. [Pg.470]

Accident Mitigation 28 Detection of leaks/ruptures 29 Emergency shutdown switch locations 30 Accessibility of isolation valves 31 Potential for fire/explosion in unit affecting other equipment 32 Critical controls, mitigation, communication, and fire protection sy stems functional and accessible after initial explosion or release 33 Back-up power supply/redundant feeds for critical electrical systems 34 Water supply for fire fighting 35 Routing of utilities... [Pg.31]

The local fire department arrivedjust after the explosion at 11 22 A.M. With the limited water supply on two of the fire trucks and the utilization of another fire truck to pump water directly from a nearby cooling water tower basin, the firemen were able to slow the fire spread. By 11 30 A.M., the Maintenance Department was able to transfer the set of batteries from the impaired diesel fire pump to the other diesel fire pump. On completion of this task, this diesel fire pump was started. The automatic deluge sprinkler protection was severely damaged by the fire/explosions and had to be valved into the off position. Three fixed monitors were turned onto lull flow and directed at the fire. Also, the firemen and fire brigade used two hose streams olF nearby fire hydrants for fire fighting purposes. At 11 58 A.M., the fire was under control. Final fire extinguishment was accomplished by 12 10 p.m. [Pg.371]

Figure 12-1 shows the basic equipment found in a distillation feed system. Compressed air or nitrogen systems are also used in the feed system. Nitrogen is an inert gas that provides protection from fire or explosion. Compressed air is used to open, close, or throttle control valves. Basic instrument systems used in the feed system include indicators, control loops, recorders, and analyzers. [Pg.267]


See other pages where Control valves fire, explosion protection is mentioned: [Pg.280]    [Pg.6]    [Pg.100]    [Pg.2508]    [Pg.1490]    [Pg.2488]   